Insertion Loss & Return Loss
-
product
Transformer Loss Measurement Systems
Measurements International Ltd.
The Transformer Loss Measuring System stands as a pivotal tool in ensuring the quality assessment of transformers. It plays a vital role in accurately measuring and evaluating the transformer’s performance by assessing both its no-load loss and load loss. Understanding these losses is essential in determining the efficiency and overall quality of the transformer, offering valuable insights for maintenance and improvement strategies.
-
product
Two-Way Optical Loss Test set
KI23422OLV-INGAAS
A Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on single mode fiber at 1310 / 1550 nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use.
-
product
VTAC, Insert Bundle, Receiver/ITA, SIM, Right Angle and Pass-Thru
610151106
VTAC, Insert Bundle, Receiver/ITA, SIM, Right Angle and Pass-Thru.
-
product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-112
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
HFC 8 Ways Return Path Optical Receiver
HR2080A, HR2080B
Hangzhou Huatai Optic Tech. Co., Ltd.
HR2080 series HFC 8 ways return path receiver can convert upstream optical signal to RF signal at the head-end and remote control center. 8 independent receivers integrated into a 1RU 19” casing to supply service for HFC network terminal. Receiver's low noise design, -22dBm receive sensitivity can provide service to farther place. There are two versions of this receiver. HR2080A with LCD on the front panel, HR2080B without LCD. All receivers are temperature tolerance type can be installed in any network surroundings including out-door type. Both of these two types can adopt SNMP function which can control the front panel to realize optimization work at the head-end and remote installment.
-
product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Hand Insertion Tools
Zierick Manufacturing Corporation
Ideal for low volume, short run and prototype PCB assembly applications, Zierick’s hand tools offer a simple and reliable method for inserting press fit and splay mounted terminals. The hand tool can be easily installed on any type of press machine for increased flexibility and faster insertion. With the addition of a lower tool die, terminals can then be splayed and locked into place to improve reliability and prevent part removal and rotation. Zierick hand tools are available for PCB-mounted quick-disconnect terminals, quick-disconnect receptacles, post receptacles, test points and IDC terminals. Simple and reliable method for inserting press-fit and splay mounted terminals. Single tool can handle multiple terminal insertion applications. Tools can be installed on almost any type of manual or pneumatic press. Please click here for a PDF user manual for Zierick's hand tools.
-
product
VTAC, Insert, Receiver/ITA, SIM, Vertical Header, 8 Pos
610151107
The VTAC vertical header insert contains 8 VTAC high speed contacts and is designed to mount directly to a PCB. It can be configured as a backplane connector and daughterboard connector. Also sold as a set with 610151108.
-
product
PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
778572-14
7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
product
VTAC Insert
The configurable VTAC high speed data insert features a data transfer rate of more than 12.5 Gbps per differential pair. Gold-plated, self-aligning contacts are specifically designed to reduce crosstalk to increase signal integrity during HSD transfers while maximizing cycle life.Each VTAC insert has a cycle life of over 150,000 without signal degradation.
-
product
Optical Loss Test Set/Light Source/Optical Power Meter
The CMA5 series (Optical Loss Test Set/Light Source/Optical Power Meter) offer superior accuracy and reliability for evaluating a wide range of optical devices and systems including WDM.
-
product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A
40-194A-002
The 40-194A-002 is a 7-Channel Fault Insertion switch with two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Micro Power, Header Insert, Receiver/ITA, SIM, Right Angle, 2 Pos, 2 Slot
510181103
This header insert contains 2 right-angle micropower contacts and is designed for soldering directly to a PCB as part of the Infinity Connector system. It is used in the 90 Series SIM Module and occupies 2 of the 34 slots in this module.
-
product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
The 42-205-008 (PXIe) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
product
PCI Fault Insertion Switch Range for Differential Serial Interfaces
50-200/201
Pickering Interfaces, a leading supplier of modular signal switching for electronic test and simulation, is expanding its range of PCI Fault Insertion switching with the introduction of two new modules (models 50-200 and 50-201) designed for use with differential serial interfaces. PCI Fault Insertion Switch Cards for Differential Serial InterfacesThe new modules include the Differential PCI Fault Insertion Switch (model 50-200) which is designed for lower data rate serial interfaces such as CAN and FlexRay, and the High Bandwidth Differential PCI Fault Insertion Switch (model 50-201) which is designed for higher data rate serial interfaces such as AFDX and 1000BaseT Ethernet. Each module allows the introduction of fault connections that include data paths open, data paths shorted together, and data paths shorted to externally applied faults such as power supplies and ground. The software driver defaults to a protective mode where conflicting faults are prevented to avoid accidentally shorting unintended paths, such as power to ground. A separate mode allows complete freedom in setting fault patterns.
-
product
Optical Loss Test Set
KI23424OL-INGAAS-APC
A Quad Two-Way Optical Loss Test set / OLTS fiber tester that's perfect for medium to ultra high fiber count loss, length & optical return loss testing applications on both multimode and single mode fiber with APC connectors on both ports at 850 / 1330nm 1310/1550 nm. A pair of these compact SM & MM instruments set new standards of productivity, ultra-stable source accuracy and ease of use.
-
product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Automated Fibre Loss Test Set
LTS-1500
The LTS-1500 is a small, rugged automated fiber optic loss test set that characterises singlemode fiber links at wavelengths of 1310, 1490 and 1550 nm. It is comprised of a sensitive InGaAs based optical power meter calibrated at six wavelengths with better than -75 dBm noise level plus a stabilised laser light source with up to three selectable wavelengths.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
Low Loss Cable Assemblies
True Blue
The Answer: An unmatched combination of low loss, durability, and value.The Question: What does Teledyne Storm Microwave’s True Blue® line of cable assemblies provide?For more than 30 years, our True Blue® assemblies have been the winning choice of design, test, and production engineers for:- Military and aerospace design-in applications- General purpose test applications- Production testing- With a design based entirely on high-performance materials, the True Blue® line covers frequencies from DC to 50 GHz.Assemblies are available in both custom configurations and a variety of standard lengths and connector combinations.The basic True Blue® cable is designed to be durable. However, for applications requiring added durability, assemblies are also available ruggedized, armored, and soft armored.
-
product
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)
510181111
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)Compatible with 410130116, ITA, i2 MX, 22 Slot VTAC/SIM Insert, EMI, and XL version 410130133Not loaded. Thermocouple patchcords need to be purchased separately.
-
product
Tool, Extraction, SIM QuadraPaddle, Receiver Insert Contacts
910112131
Tool, Extraction, SIM QuadraPaddle, Receiver Inserts
-
product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
product
Technology Insertion
Technology insertion allows customers to seamlessly integrate new, higher performance hardware technologies while retaining form, fit and function and application software compatibility.Over that time, application requirements change and grow – demanding greater computing horsepower. In recognition, we have put technology insertion at the heart of our product design, enabling our customers to leverage new levels of capability at lower cost and with minimal disruption.
-
product
Magnet & Integrated Variable Temperature Sample Space With DR Insert
Adapted MCK model DR inserted into 50 mm 1.6 K300 K VTI VTI cooling power used for condensing stage of DR Versatile solution as the magnet system can also be used with other inserts and measurement probes including He3, heated probes, rotator, VSM etc.
-
product
PXI 34x4 Signal Insertion and Monitor Matrix
40-525A-001
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also availablein a 16x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system. Each pass thru connection from LX to X can be open or closed to allow the programmatic disconnection of the signal to check the response of the UUT. The matrix can be used to connect test equipment, such as a DMM or scope, to monitor the pass thru signals via Y connections while the LY connections can be used to insert a fault condition or insert external signals. When external signals are injected the LX connections can be opened and the LY connections closed.
-
product
Battery Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.