Insertion Loss & Return Loss
-
product
RTD / PRT Platinum Sensing Resistor Inserts
RTD / PRT Platinum Sensing Resistor Inserts - Ceramic Sheathed, Pt100 & Pt1000 Inserts
-
product
SM & MM Quad Optical Loss Test Set
KI2724-INGAAS-APC
A SM & MM Quad Optical Loss Test Set used to test power, insertion loss, continuity and faults on multimode and single mode fiber with an APC connector at 850 / 1300 nm & 1310 / 1550 nm. In a small package, it provides a powerful solution to improve test flexibility and productivity.
-
product
PCI Fault Insertion Switch Cards
Pickering's PCI Fault/Signal Insertion Switch Cards feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system.
-
product
PXI Signal Insertion Switch Module
PXI Signal Insertion Switch Modules, also known as fault insertion units (FIUs), provide a set of feedthrough channels, which make the switch transparent to the system when closed. You can open or short these channels to one of two fault buses, allowing you to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI Signal Insertion Switch Module can validate the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs). You can also use the FIU models for hardware-in-the-loop (HIL) applications and electronic reliability tests.
-
product
Patchcord, Signal, Receiver, 36", QuadraPaddle Insert, Single Ended
7-152924000-036
Patchcord, Signal, Receiver, 36", QuadraPaddle Insert, Single Ended
-
product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A
40-192A-012
The 40-192A-012 is a PXI fault insertion switch using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
product
Low Loss Combiners
*Tunable or band specific low loss combining of Tx and Rx*Typical 0.7dB insertion loss*Optional second duplexer can be installed in the same tray*High power handling with low IM and insertion loss*AISG 2.0 compliant
-
product
MX Series - i2 Modular Inserts
VPC i2 MX inserts offer standard and hybrid transmission options for both wired and PCB solutions.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Digital Program Insertion Auditor
Torque DPI
The DPI Auditor supports the ANSI/SCTE 35 2001 standard that defines a fully digital mechanism to control remote splicing equipment via cueing messages embedded in the transport stream. The core of the standard is centered on an SIT (Splice Information Table) which can contain a schedule message or an insert message.
-
product
Reactor Loss Measurement Systems
Measurements International Ltd.
The AccuLoss® SR2020 System by Measurements International emerges as a premium, dependable solution tailored for measuring losses in high-voltage shunt reactors. Specifically engineered to function seamlessly at remarkably low power factors, this system excels in applications demanding extensive scalability. Notably, the AccuLoss® SR2020 System offers two key advantages: unparalleled accuracy and remarkable speed.
-
product
Signal, Patchcord, ITA, 72", QuadraPaddle Insert, Single Ended
7-151924000-072
Signal, Patchcord, ITA, 72", QuadraPaddle Insert, Single Ended
-
product
Insertion Flow Meter
SPI Mag
The SPI Mag Insertion Flow Meter provides a highly cost-effective solution for the accurate measurement of liquid flow in closed conduit, pressurized pipe applications. Unlike conventional magnetic meters, the SPI Mag's cost is independent of pipe size.
-
product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch
40-190B-002
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Adapter Rails (for High Speed Inserts), i2MX, ITA, 88 Pos, 11 Slot
510144001
Allows use of SIM inserts in i2MX ITA. Accommodates 11 single-slot inserts.
-
product
PXI 16x4 Signal Insertion and Monitor Matrix
40-525A-002
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also available in a 34x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system.
-
product
ITA, i2 MX, EMI, w/ 2 Hybrid Module Inserts
410130204
This model i2 MX includes 2 Hybrid Module inserts. Each module insert offers 8 Mini Power/Coax and 8 TriPaddle positions. Includes front protective cover.
-
product
VTAC Vertical Header Insert
The VTAC vertical header insert is designed to mount on custom PCBs. Can be configured as a backplane connector and daughterboard connectors. Also sold as a set under 610151108.
-
product
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position
510143008
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position.
-
product
PXI Fault Insertion (Fault Injection) Modules
PXI Fault Insertion Units (FIU), also known as Fault Injection switch products, are designed specifically for safety-critical applications where the response of a control system is required to be evaluated when sensor connections behave in unexpected ways. These modules are scalable solutions that can be used to switch signals between simulations and real-life devices in a multitude of hardware-in-the-loop (HIL) simulation and test systems. The fault insertion unit can significantly simplify and accelerate the testing, diagnosis and integration work in HIL applications.
-
product
RFoG 4 Ways or 8 Ways Return Path Optical Receiver
RFoG6000
Hangzhou Huatai Optic Tech. Co., Ltd.
RFoG6000 series Return Path Receivers are an integral part of two-way RF access networks, converting upstream optical signals into RF signals at the head-end or remote hubs. 4 or 8 independent receivers are packaged in a 1RU 19-inch rack-mounted unit, serving 256 RFoG optical network terminals (ONTs). A low-noise receiver design improves noise performance by 4dB or more over typical return receivers. Low noise enables DOCSIS 3.0. -32dBm receives sensitivity, allow upstream PON-bound design, such as: supporting 32 splitting way in 20km, 64 splitting way in 10km.
-
product
HFC 7 Ways Return Path Optical Receiver 1 Way Reverse Optical Transmitter
HR2071A, HR2071B
Hangzhou Huatai Optic Tech. Co., Ltd.
HR2071 series of HFC seven-way return path receiver, one way reverse optical transmitter, mainly used at the head-end to convert upstream optical signal to RF signal at the user side. Moreover, send back the data at sub-HE to main head-end through one way of DFB return path transmitter. Eight independent units integrated into a 1RU 19" casing to provide service for HFC network terminal of ONTs. The receivers’ low noise design of -22dBm receive sensitivity, allow to supply service to farther distance. There are two versions of this receiver. HR2071A with LCD on the front panel, HR2080B without LCD. All receivers are temperature tolerance type can be installed in any network surroundings including out-door type. Both of these two types can adopt SNMP function, which can control the front panel to realize optimization work at the head-end and remote installment.
-
product
OPTICAL LOSS TEST SET (OLTS) MQJ KIT
4000-1025
The OLTS (Optical Loss Test Set) - MQJ Kit includes a soft, padded carrying case with strap that is provided to protect all of the components during transportation and/or storage.
-
product
PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module
778572-12
7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
product
Dielectric Loss Tangent Testing Instruments
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
product
Loss Test Set
Combines functionality in a compact test kit designed for performing length, loss (Tier 1) testing and inspection capability on both multimode and single-mode fibers.
-
product
PXI 1A Fault Insertion Switch 22-Channel
40-195-001
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.
-
product
Optical Return Loss (ORL) Meter
OPTOWARE-S300 (FOTS-ORL Meter Systyem)
The Optical Return Loss(ORL) Meter is an efficient system for the characterization and test of optical components and systems to be performed in high quality.
-
product
Free Room Temperature Bore magnet with Insertable DR
Room Temperature magnet bore 50 mm sample space in DR Suitable for use with Leiden DR type CF200, CF450, CF650 or CF1000 DR