Filter Results By:
Products
Applications
Manufacturers
-
product
Fully Automatic Transformer Winding Resistance Tester
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
product
Tester for Alternator Stator Windings and Diode Bridges
MS014
The equipment combines two devices: tester of stator windings and diode bridges. The device has small dimensions and a light weight, it was developed according to the requirements of contemporary service stations.The feature of the handset tester is diagnostics of stator windings and diode bridges with no additional testing and measuring devices.Diagnostics of stator windings is carried out through automatic identification of phase connection, detecting winding integrity and measuring the difference in phase distortion.
-
product
Automatic Production Tester for Electric Motor Stators
MTC 3
The fully automatic MTC3 stator testers test your windings reliably and quickly for possible insulation faults via our patented surge voltage test.After connecting the test object completely the test is performed with an automatic switching of the connections and the test methods. The MTC3 evaluates each test step. At the end of the complete test process it provides a clear and reproducible GO or NO GO-statement.
-
product
Transformer Winding Resistance Meters
RMO TT Series
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
product
Current Transformers
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
product
Tap Changer Analyzers & Winding Ohmmeters
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
product
Electrical Measurements Test
The tests are performed to measure and collect data from electrical and electronic parts using various measurement methods including, but not limited, to the following: capacitance, resistance, winding resistance, insulation resistance, magnetic permeability, power input, and quality factor Q.
-
product
Automatic Transformer Tester
CVCT-S20
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
Single Phase Impulse Winding Tester 3 kV
SME1203
Scientific Mes-Technik Private Ltd
Single Phase , 3 kV Impulse winding testing Low inductance impulse test: down to 10 μH Low energy test without damaging the coil Fast detection of winding insulation at a speed of 5.5 Meas/sec 4 kinds of waveform comparison methods Up to 40 MSPS sampling rate 320×240 dot-matrix graphic LCD display Multi-trigger mode programmableVoltage, Time and Frequency measuring functions Direct display of comparison result
-
product
Brushless Motor
Citizen Chiba Precision Co., Ltd.
*High output *The rotor uses Nd magnets. *The stator was designed for maximum output per unit volume to maximize winding.*Long service life *Since these are brushless motors, the only limit to service life is how long the ball bearings last.
-
product
Bobbin Winding Coil Tester
SS108A series
Bobbin winding coil testers are used to test various coil of turns. Such as: generator winding turns, transformer winding turns, motor winding turns, inductor winding turns, contactor winding turns, relay winding turns, sparking winding turns, ignition winding turns, speaker voice coil, etc.
-
product
Standard CT
6300A
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
product
Digital High Frequency Surge Testers
C Model
These Digital High Frequency Surge Testers are the ultimate in ruggedness & durability. Fourteen / sixteen gauge steel construction and mobility on 6" heavy duty rubber wheels makes it a favorite for use in harsh industrial environments. The performance of PJ's exclusive/unique High Frequency Technology is capable of testing the integrity of any turn-to-turn insulation, including low inductance windings.
-
product
200KHz AUTOMATIC TRANSFORMER TEST SYSTEM
VE2729XAU
Its a Microprocessor Based 200KHz Automatic Transformer Tester with inbuilt 20 Pin Channel Scanner for Automatic Switching and Testing Coils & Transformers (Ferrite) with Max. 20 PINS. Test Parameters : -> Inductance (L)-> Leakage Inductance (Lk)-> Capacitance (C)-> DC Resistance (Rdc)-> AC Resistance (Rac)-> Turns Ratio with Winding Polaity-> Quality Factor (Q)-> Impedance (Z)
-
product
Dry Testing Transformer
GTB Series
Wuhan Sangao Electrical Test Installations Limit Co.
GTB series dry testing transformer is adopted with new technology of winding epoxy vacuum pouring and CD type Iron core. Compared with similar product of oil immersed type transformer, it is light weight, smaller size, insulation strength and moisture-resistant is more improved.
-
product
Spring Back Tester
HTJ-16
Shanghai Dean Electrical Co., Ltd
Executive standard: GB/T4074.3-2008/IEC60851-3; Inspection standard: JB/T4279.4-2008Used to measure the spring back characteristic of enameled round wires with nominal conductor diameter of between 0.080mm and 1.600mm;Number of winding turns: 5 turns and a halfStop accurately at zero position of the scale after automatic windingAs soon as the value of spring back angle stop counting, the dial will stop to rotate immediately, so that the value displayed on LED and read on the dial are the same.Sensor is unnecessary to be adjusted for samples of different specificationsCoils loosen slowly during spring back, no action of spring back or jump suddenly.Application of SCM control allows for fast operation and strong anti-interference capacity;
-
product
Multi-Channel, Programmable Current Source
CS-48-100
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.
-
product
Transformer DC Winding Resistance Tester
HTZZ-20A / 240
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement transformer around the group and large power inductor dc resistance ideal equipment.
-
product
Surge Testers
MTC 2
Advanced automatic high precision electrical winding testers for testing products like alternators, stators, transformers, armatures and motors. Available as static or portable units from 6-50 kV.
-
product
Coil Tester
It is a new impulse winding tester that incorporates high precision, a wide range of functions, various expandability, improved operability, and a full range of external communication interfaces.
-
product
Mini Automatic Transformer Observation System
mini-ATOS
The mini-ATOS, is a professional multifunctional power transformer and substation diagnostic system. This compact and intelligent instrument can perform many routine and advanced tests such as Winding Resistance (WR), Dynamic Resistance Measurement (DRM), Turns Ratio (TR), Frequency Response of Stray Losses (FRSL), Magnetic Balance, and other diagnostic parameters. With the built-in fully automatic multiplexer, only a one-time connection is required for nearly all functions, which saves a considerable amount of time. The portable, rugged case is perfect for use anywhere onsite or in a laboratory. It is specially designed for fast and easy measurements with the well-known high precision and quality of all Raytech instruments.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Saturable Reactor Inductors
Osborne Saturable Reactors are designed to provide a variable output voltage through the use of variable impedance connected in series with a constant impedance load. Each saturable reactor’s impedance is determined by the application of DC power to a control winding. As the level of power supplied to the control winding is increased, the saturable reactor becomes more saturated. This reduces the impedance of the AC gate winding, and increase the amount of the supply voltage that is transferred to the load. Conversely, as the power is reduced to the control winding, the reactor becomes less saturated, the gate winding has more impedance and less of the input voltage is provided to the output impedance. This approach provides excellent quality, reliability, and control when designed to match the requirements of a specific application.
-
product
Transformer Heat Run Tester
1. Suitable for all transformers below 240MVA heat run test and winding resistance testing.2. Printing heat run data automatically.3. With double power supply, can test high voltage side and low voltage side simultaneously and test any operation respectively.4. With anti breakage protection function of inductive test items.
-
product
Insulation Tester
61-797
*Checks new installation for damaged insulation*Checks existing installations and motor windings for breakdown in insulation*2-year warranty
-
product
Micro OHM Meter
Cambridge Instruments & Engineering Co.
This Test set is capable to measure low resistance like switch contacts, breaker contacts, busbar slices, joints, fuses, low inductive windings etc.