IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- support@dv-power.com
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
Product
Battery Voltage Supervisor
BVS
-
DV Power battery voltage supervisor – BVS, is an accurate battery voltage monitoring system that monitors the state of health of battery systems. It records important battery parameters such as battery voltage, inter-cell connection voltage, and ambient temperature. Because of that, it can be a support tool for capacity testing.The BVS voltage supervisor is an integrated system consisting of:BVS Control Unit (BVS-CU)Cell Voltage Modules (CVM)String Voltage Module (SVM) (optional)String Current Module (SCM) (optional)It is an ideal testing tool for maintenance, troubleshooting and performance tests on individual stationary batteries and battery packs in critical backup energy solutions.BVS-CU provides ambient temperature measurements on multiple locations (4 temperature channels). Overall string voltage and string current monitoring can be achieved by using an optional string voltage module (SVM) and string current module (SCM).There are two types of DV Power battery voltage supervisors:BVS – One cell voltage module measures 1 cellBVS-4 – One cell voltage module measures 4 cellsCVM modules detect cells that fail a discharge test based on monitored voltage values. As a result of that, these cells can be safely removed from the battery string.Data acquisition and analysis of data collected from the modules are available in the DV-B Win application software suite. They provide data viewing, tracking, and generation of comprehensive reports.
-
Product
Ground Grid Tester
GGT Series
-
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.
-
Product
Circuit Breaker Analyzers & Timers
-
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.
-
Product
Micro-Ohmmeters
RMO-G Series
-
The RMO-G is a portable micro-ohmmeter designed for contact resistance measurement of non-inductive test objects and applications with increased safety requirement. It tests medium and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. Due to its Both Sides Grounded and Remote Control functionalities, the instrument accurately measures even in the most demanding environments, providing additional safety to testing personnel.The RMO800G is the most powerful portable micro-ohmmeter on the market with 800 A output current. RMO200G is our best seller in the USA. A user can choose the appropriate model depending on the output current requirement, from 100 A (RMO100G) to 800 A (RMO800G).We use an unbreakable plastic case with IP67 protective rating (with closed lid) for instruments’ housing. Although very portable and lightweight, RMO-G micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents. Consequently, it enables the usage of thinner/longer test cables. RMO-G generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. During the testing, it increases current before measuring and decreases current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.Special current clamps measure a current through groundings when the instrument tests in Both Sides Grounded conditions. The instrument itself powers these clamps. If even higher safety level is required, the Remote Control feature enables the operator to perform measurements from distant locations.RMO-G instruments can store up to 500 measurements in internal memory. Also, they have a built-in thermal printer and USB flash drive available as an option. An additional option is the built-in High Precision module suitable for measurement of very low resistance, in the range from 1 to 30 µΩ, with 0,01 µΩ resolution.Our free DV Win software communicates with the RMO-G micro-ohmmeters via USB or RS232 interface. It allows a user to run the test remotely from a PC. Also, a user can download test results, analyze and generate fully configurable test reports through the software.
-
Product
Tap Changer Analyzers & Winding Ohmmeters
-
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
Product
Battery Supervisors
-
DV Power manufactures ideal tools for maintenance, troubleshooting and performance tests on stationary batteries.Capacity testing is performed in order to detect which cells in the string should be replaced by measuring a cell voltage, temperature, inter-cell connection voltage, and specific gravity.IEEE standards for stationary battery applications also stipulate measuring these key parameters during periodic battery inspections.DV Power provides two types of instruments:BVS series – for automated monitoring of battery parametersBVR series – for manual monitoring of battery parametersIn contrast to BVS, BVR instruments can be used for the transfer of electrolyte specific gravity measurements from a density meter (DMA35) via Bluetooth. This provides a more extensive analysis of each cell in the tested battery string.
-
Product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
-
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
Product
Battery Chargers
-
Following a power outage, various power engineering objects such as power plants should operate on battery back-up systems. It is necessary that these batteries are being properly charged in order to compensate its energy loss and keep their voltage within the predefined limits. DV Power’s chargers are portable and universal battery charging solution. They are primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300 V DC level.Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge. Variety of implemented protections, such as thermal, overcurrent, undervoltage and overvoltage, assure the charging process is safe for the battery and the charger itself.
-
Product
Motor/Generator Test Equipment
-
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.
-
Product
Battery Extra Load Units
BXL Series
-
BXL is an extra load unit designed to be used with DV Power’s BLU series battery testers. However, this unit is a universal add-on device. Because of that, it is compatible, as an additional load, with any other discharge/capacity tester in the market.In case when discharge current exceeds the capacity of a single BLU device, BXL can increase the discharge capacity. There are no limitations on the number of extra load units that can be connected in parallel to the main battery tester.A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way. Also, all instruments are in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.These units can be used on any type of battery string, such as lead-acid, Li-Ion, Ni-Cd, etc. They test battery strings with voltages in the range of 5,25 – 500 V DC. On the other hand, current up to 250 A can be discharged through the BXL internal structure.The instrument simulates a constant resistance load during the discharge test. Several resistances can be set for different battery nominal voltage levels. This makes BXL extremely flexible in selecting its load capabilities.
-
Product
Battery Extra Load Units
-
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
Product
Battery Capacity Testers|Discharge Testers
-
DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Coil Testers & Power Supplies
POB Series
-
Coil testers and power supply units, models POB30 and POB40 are ideal for commissioning and maintenance testing of circuit breakers. The station supply is not available. The POB series are power supply units implementing the latest power electronics technology. They are developed for use in switchyards, power and industrial environment. In addition to providing current and voltage for breaker testing, they can measure certain coil parameters.
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.