Potential Transformer
a type of intrument transformer enabling secondary connected metering.
-
product
Transformer Bench Tester
KVBT
KV Hipot Power Test Equipment Co.,Ltd
Transformer Test System is applied for ex-work and maintenance detecting on various transformers.
-
product
200KHz AUTOMATIC TRANSFORMER TEST SYSTEM
VE2729XAU
Its a Microprocessor Based 200KHz Automatic Transformer Tester with inbuilt 20 Pin Channel Scanner for Automatic Switching and Testing Coils & Transformers (Ferrite) with Max. 20 PINS. Test Parameters : -> Inductance (L)-> Leakage Inductance (Lk)-> Capacitance (C)-> DC Resistance (Rdc)-> AC Resistance (Rac)-> Turns Ratio with Winding Polaity-> Quality Factor (Q)-> Impedance (Z)
-
product
Hi Potential & Cable Continuity Test Fixture
HIPOTCCT
The most important features of this hipot tester fixture is its safety and ease of use intuitive control functions and durability in a production environment.
-
product
Automatic Voltage Transformer Comparator
KATC-V2
Knopp’s KATC-V2 is a highly accurate state-of-the-art voltage transformer comparator that is compatible with all older generation Knopp comparators, and is designed to be a direct, plug-in replacement with additional test set cables to fit in the existing Knopp Voltage Transformer Test Systems.
-
product
Software For Transformer Measuring Lite
T-Base Lite
T-Base Lite is intended for users preferring simplicity over complexity of the Pro version. It is limited to the basic functions of USB interface, data import, data export, synchronization, and automatic firmware updates. Data can be exported in many popular data formats such as Excel, Word, text, .csv, .xml, Crystal reports, and .html. Measurements can be saved as archive files and imported into the database of the T-Base Pro version.
-
product
Automatic Transformer Test System
TH2829LX
Changzhou Tonghui Electronic Co., Ltd.
Number of Test PIN: 20 ■ Frequency: 20Hz-200kHz, Resolution: 0.5mHz ■ Signal Level: 5mV-2Vrms(Option:2mV-10Vrms) ■ Test Speed: max. 13ms ■ 7-inch TFT LCD display with a resolution of 800×RGB×480
-
product
Transformer Short Circuit Impedance Tester
JYW6300
This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.
-
product
Digital Brix / Potential Alcohol Refractometer
MA884
Thousands of food and beverage professionals and hobbyists, from chefs and food quality professionals to brewers and wine makers, have moved to digital MA884 Digital Brix and Potential Alcohol meter for measurement from less accurate and less precise optical refractometers.
-
product
Transformer Rated Pre-Wired Meter Enclosures
TESCO Transformer-Rated Pre-Wired Meter Enclosures are built with the TESCO tradition of quality and durability. TESCO enclosures are designed for use in commercial and industrial metering installations where voltage ratings of 480 and above are required. The enclosures are available with ringless, single piece or two piece covers and can be pre-wired between the test switch and socket to meet your exact specifications.
-
product
Flux Testing Transformer
The testing equipment is manufactured in strict adherence with industry standards using superior quality raw materials, sourced from reputed vendor in market.
-
product
High Frequency Current Transformer
HFCT
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
product
Adjustable Isolating Transformers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).
-
product
Precision Multirange Voltage Transformers
WP-36000
The WP-36000 Transformer is primarily a laboratory standard. The high degree of accuracy and multiplicity of ranges makes this transformer the standard for precision calibration work. With the aid of this transformer, very accurate determination can be made of the ratio and phase angle characteristics of voltage transformers having ratings from 14,400 to 36,000 volts.
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
Fourier Transform Optical Spectrum Analyzer, 600 - 1700 nm
OSA202C
Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.
-
product
Fully Automatic Transformer Turns Ratio Tester
DY100
DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Instrument Transformer Calibrators
MRL 11
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
product
Automatic Instrument Transformer Test Set
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
product
Transformer Insulation Testing
The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).
-
product
Isolation Transformers 230V
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
product
Distribution Transformer Tester
DOC-2000™
The DOC-2000™ is a test instrument designed for distribution networks transformers up to 167KVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The DOC-2000™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
product
Instrument Transformer Testing
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
product
Voltage Transformer
Beijing GFUVE Electronics Co.,Ltd.
Are a parallel-connected type of instrument transformer. They are designed to present a negligible load to the supply being measured and have an accurate voltage ratio and phase relationship to enable accurate secondary connected metering.
-
product
Constant Potential Generator Power Supply Mains
CP225D
Supplemental to its outstanding penetration capacity (up to 47 mm for steel in just 10 minutes), the CP225D includes a built-in multiple X-Ray output carrousel that features a Beryllium window for the inspection of lighter alloys such as aluminum and carbon fiber. The CP225D is one of the most versatile generators on the market and will adapt to an extremely wide variety of applications. In fields as diverse as the construction or petrochemical industries, its power and small focal spot, light weight, compactness and high penetration capacity will be much appreciated.
-
product
Transformer Ratio Meters
TRM-200
Three phase lead switching network • Excitation current meter Accessories: Range Extender 1:5.
-
product
Automatic Transformer Test System
TH2829CX
Changzhou Tonghui Electronic Co., Ltd.
Number of Test PIN: 20 ■ Frequency: 20Hz-1MHz, Resolution: 0.5mHz ■ Signal Level: 5mV-2Vrms(Option:2mV-10Vrms) ■ Test Speed: max. 13ms ■ 7-inch TFT LCD display with a resolution of 800×RGB×480
-
product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.