Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
E-Series Average Power Sensor
E9301A
-
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Hydrophone
RESON TC 4032
-
The TC4032 general purpose hydrophone offers a high sensitivity, low noise and a flat frequency response over a wide frequency range. The high sensitivity and acoustic characteristics makes TC4032 capable of producing absolute sound measurements and detecting even very weak signals at levels below “Sea State 0”. The TC4032 incorporates an electrostatically shielded highly sensitive piezoelectric element connected to an integral low-noise 10dB preamplifier. The TC4032 preamplifier is capable of driving long cables of more than 1.000 meters, and the preamplifier features an insert calibration facility.
-
Product
Power and Energy Automated Calibration System
RS-933
-
The RS-933 Syntron Power and Energy Automated Calibration System calibrates a range of test equipment including; Energy Reference Standards, Digital Multimeters, Phase meters, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters & Power Quality meters.
-
Product
Multi Purpose FT-NIR Analyzer
MPA II
-
The MPA II is the result of more than 40 years of experience in the engineering and production of FTIR and FT-NIR spectrometers. It is a powerful tool for developing sophisticated calibration methods for your laboratory or process needs, yet an easy to use QA/QC instrument for routine work. With its modular technology, it can be configured individually for each analytical task.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
PXI RTD Simulator Module 18-Channel PT1000
40-262-002
-
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
Pressure Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
In any industry, a lot is usually riding on strict pressure settings like the operations, safety systems, etc. Pressure calibrators help in ensuring that the pressure devices are measuring and displaying accurate values. Nagman offers a range of well built, rugged, reliable, easy to use, budget friendly options of pressure calibrators that you can choose from based on your needs.
-
Product
Trace Level Chemiluminescence NO-NOy Analyzer
Model T200U NOY
-
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
Product
CrystalControl
-
AMETEK Sensors, Test & Calibration
CrystalControl is a software program used to customize, update, and calibrate the nVision Reference Recorder, HPC50 Series Pressure Calibrator, and the HPC40 Series Pressure Calibrator. In addition to providing an easy way to customize your nVision Reference Recorder, it also provides a way to store and archive your recorded data runs.
-
Product
P-Series Dual Channel Power Meter
N1912A
-
30 MHz video bandwidth Single shot real time capture at 100 M sample/s per second Key Measurements: - peak, average, peak-to-average ratio, rise time, fall time and pulse width22 Predefined formats: WiMAX, DME, HSDPA, etc. One screen view for pulse measurement analysis: Auto Scale, Auto Gate, Rise/Fall Time, Duty Cycle, etc. Internal Zeroing and Calibration while connecting to the DUT Bench Vue software enabled
-
Product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
-
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
Product
Probes And Cables
-
The iProbe is an intelligent temperature sensor that can be calibrated independently of SBIR’s blackbody systems or 104i precision thermometers. These ultra-stable, highly responsive iProbes are used to provide long term accuracy and repeatability of under 0.010°C. Each iProbe incorporates onboard flash memory that allows all calibration constants and calibration date information to be stored independently of the blackbody or thermometer system. This allows iProbes to be exchanged for use on a blackbody or thermometer without any loss in stability or accuracy. To re-calibrate a system you need only exchange the current iProbe with a recently calibrated one. No special equipment is required and there is no down time in the test area.
-
Product
Pressure Module
APM CPF
-
AMETEK Sensors, Test & Calibration
The APM CPF Series portable pressure modules offer the functionality and flexibility to perform pressure calibrations with a multifunction process calibrator. Or, combine with a hand-held pressure calibrator to expand its range. The APM CPF delivers the same high level accuracy whether in the lab or in the field.
-
Product
Signal Conditioner
SA420
-
Features• Works with a remote / external pulse frequency output sensor(NPN, PNP, or Mag Pick-up)• Accepts wide range of input frequencies 0.01 Hz to 10 kHz• 4-20 mA and 0-10 VDC outputs proportional to shaft speed• Field adjustable calibration• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• DIN rail mount
-
Product
UV Sensors
-
With analog (4-20mA, 0-5V, 0-10V) or digital (USB, Modbus) output, also available with Android device (incl. app). SiC photodiode chip based Broadband UV sensitivity or filtered for UVA, UVB, UVC or UV-Index spectral sensitivity. Our sensors are also available with logarithmic signal transduction, linearity from 0 … 1500 mV. Calibration services available at our Berlin facility prior to delivery and after use
-
Product
Multi-Cal Benchtop Calibrator
MC6
-
Model MC6 Multi-Cal Benchtop Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility
-
Product
Process Calibrators
-
We offer process calibrators that are designed for the process industry applications and to be used in the demanding conditions in process industry.
-
Product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2A
-
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Product
Antenna Test Chamber for Automotive Radar
ATS1500C
-
The R&S®ATS1500C radar test chamber is a compact antenna test range (CATR), consisting of a gold-plated parabolic reflector and a two-axis positioner for 3D movements of the radar module. Combined with the R&S®AREG800A target simulator and other Rohde & Schwarz test and measuring instruments, it can be used for a variety of applications, including antenna characterization, module calibration, RF performance validation, interference testing or in-band compliance testing. The chamber is equipped with a universal feed antenna which gives access to both polarizations in parallel. Automated temperature testing over the range of -40 to 85°C is possible with an optional enclosure.
-
Product
GPC/SEC Data Systems for Enhanced Control and Performance
-
Agilent GPC/SEC data systems enable powerful control, data acquisition, calculations, and result reporting. For accurate molecular weight analysis and complete polymer and protein characterization, GPC/SEC software provides the functionality required for conventional and advanced GPC/SEC in a simple, powerful, fully integrated package.GPC/SEC software for OpenLAB CDS adds application-specific calibration, data processing, and reporting to your OpenLAB CDS. Cirrus GPC Multi Detector software, an add-on to OpenLAB CDS ChemStation, allows you to process conventional GPC data using a column calibration. Bio-SEC software is a dedicated standalone package for characterisation of proteins and other biomolecules.
-
Product
Multifunction Process Calibrators
-
AMETEK Sensors, Test & Calibration
Our multifunction process calibrators read and source RTD, thermocouple, current, voltage, frequency, and resistance to calibrate or verify your process sensors. They can also be combined with APM CPF pressure modules to calibrate pressure, or a dry-block to calibrate temperature. The ASC-400 features a large full color display with an advanced simplicity, easy-to-use interface.
-
Product
Class 1 Integrating Sound Level Meter System
NK021
-
This NK021 system includes a class 1 integrating sound level meter, class 1 acoustic calibrator, protective microphone windshield and is supplied in a hard wearing kit case.
-
Product
Current Calibrators
-
Used for basic measurements, tests and regulation techniques for setting and verifying test installations and instrumentation.
-
Product
ITO Sheet Resistance Standards (ITOSRS)
-
Indium Tin Oxide Sheet Resistance Standards (ITOSRS) from VLSI Standards are NIST-traceable products, intended for calibration of both contact and non-contact sheet resistance measurement tools used in the LCD, flat panel and touch-screen markets.
-
Product
Remote Control
10888A
-
The Keysight 10888A handheld wired remote provides at-a-distance initiation of Keysight 5530Laser Calibration System electronic components. The remote control provides a beam alignment meter and reset button, as well as a remote trigger.
-
Product
PXIe-7962, Virtex-5 SX50T FPGA, 512 MB DRAM PXI FPGA Module for FlexRIO
781206-01
-
Virtex-5 SX50T FPGA, 512 MB DRAM PXI FPGA Module for FlexRIO—The PXIe‑7962 provides flexible, customizable I/O for LabVIEW FPGA. It includes 132 single-ended I/O lines configurable as 66 differential pairs. You can pair the PXIe‑7962 with FlexRIO adapter modules that offer high-performance analog and digital I/O. Together, the two modules create a reconfigurable instrument that you can program with LabVIEW FPGA software. The PXIe‑7962 supports peer‑to‑peer streaming, which directly transfers data among multiple FPGA modules or select PXI Express modules without sending data to the host processor. With this feature, you can add FPGA capabilities to high-performance NI digitizers with NIST‑traceable calibration or expand your FPGA algorithms across multiple FPGAs for computationally demanding applications.
-
Product
Sensor Cable, 5 M
E1739A
-
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Calibrated Solar Reference Cell
-
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
Product
Portable Calibration System
HD9120
-
HD9120 is an acoustic calibrator that, in accordance with the Circular Prot. RU 34143 of 02 December 2011, allows qualified technicians to perform calibrations of sound level meters for comparison with a reference sound level meter.





























