Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
Product
Light Sources & Calibration Standards
-
Photometric Solutions International Pty Ltd
We offer a range of specialised and customised light sources for various applications.The spectral range goes from 200 nm to 40 µm.
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Spectral Radiance / Luminance Calibration Standards
-
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
UV/VIS/NIR Spectrophotometer Calibration Standards
-
As the world's foremost spectrophotometer reference standard manufacturer, we have a dedicated staff and years of experience to back up our products. Our solid state UV/VIS/NIR reference standards are the most stable on the market and remain in spec long after many other manufacturer's standards go bad. Relying on our proprietary nano-deposition technology, you can rest assured that our solid-state standards will produce steady readings for years to come on your machines.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Electrical Calibration And Standards
-
Capable of calibrating a large workload of probes in the laboratory or monitoring environments on-site in the field, Fluke humidity probe calibrators and environment monitors are used where humidity and environmental measurement is critical. Proper humidity calibration is essential to prevent spoilage or damage to products in industries including data centers, pharmaceuticals, medical devices, semiconductors, chemicals, and food production. Fluke humidity calibration tools are dependable, accurate, easy-to-use solutions, with some having the ability to monitor additional environmental conditions such as temperature and barometric pressure in a single solution.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Calibration Short For Digital Multimeters
34172B
Calibration Short
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
Electronic Calibration Module
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Economy Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052D
Mechanical Calibration Kit
The Keysight 85052D economy mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection. Connector gauges may be ordered separately.
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
Calibration Cable
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
Electronic Calibration Module
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (f)
85563A
Mechanical Calibration Kit
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Mechanical Calibration Kit
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
Temp Characterized CalPod, 20 GHz
85531B
Electronic Calibration Module
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards. Very useful in thermal chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the thermal testing to perform a normal re-calibration.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Linear Measurement Kit
55280B
Mechanical Calibration Kit
The Keysight 55280B Linear Measurement Kit is part of the 5530 Laser Calibration System and enables the system to measure linear displacement and velocity along a machine's travel path. The purpose of this measurement is to document capability and, when possible, improve positioning accuracy along an axis for any machine that requires positioning accuracy and velocity control.
-
Product
Ambient Temperature CalPod Module, 20 GHz
85530B
Electronic Calibration Module
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
Electronic Calibration Module
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.