Working Standards
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2LB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1G
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1H-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard - 5.00 (142.00) - 8.30 (235.00)
P3325-1
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
Product
Standard Modal Analysis
-
EDM Modal Standard Modal Analysis provides the user with a complete arsenal of tools, from FRF data selection and parameter identification to results validation and mode shape animation.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1C-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
4210A Rubidium Frequency Standard
-
Precise Time and Frequency, Inc.
The ptf 4210A Rubidium Frequency Standard is a unique solution for providing a highly stable, low phase noise, frequency reference for applications requiring atomic reference stability performance.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T30-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39L15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z1-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-2R1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-2W1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
UV/VIS/NIR Spectrophotometer Calibration Standards
-
As the world's foremost spectrophotometer reference standard manufacturer, we have a dedicated staff and years of experience to back up our products. Our solid state UV/VIS/NIR reference standards are the most stable on the market and remain in spec long after many other manufacturer's standards go bad. Relying on our proprietary nano-deposition technology, you can rest assured that our solid-state standards will produce steady readings for years to come on your machines.
-
Product
Standard Voltage 78 Pin D-Type Cables - Calibration Cables For Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 78-pin D-type calibration port connector.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1V1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)





























