Working Standards
-
product
Standard Current Transformer
HL / 640
Wuhan Huatian Electric Power Automation Co., Ltd.
It is used as the calibration standard of current transformer in the error test of transformer.
-
product
IEC60335 Standard Electrical Temperature Tester
CX-w15
Shenzhen Chuangxin Instruments Co., Ltd.
Standard Test corner/room conform to IEC60335-1:2004. and GB4706.1-2005. can be used to the temperaturetest of all kinds of electronic products supply, in conformity with the standards requirement of the environmental conditions.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standards Reference for Test Systems PXI Card
GX1034
The GX1034 offers PXI system designers the capability to develop a system re-certification strategy that employs only internal system resources. By incorporating the GX1034 as part of a system configuration, it is possible to develop a system accuracy verification strategy that can recertify a system's source and measure baseband instrumentation resulting in simplified support / maintenance logistics and improved system availability.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1J
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard Helmholtz Coils
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
product
O.E.M. Optical Standards
O.E.M. Optical Standards by Applied Image - Boston Scientific Checkerboard Array, Cognex Glass Calibration Plate Set
-
product
GPS Frequency Standards
Precision Test Systems manufacturers' a full range of GPS and GNSS frequency standards that are disciplined to most of the worlds satellite systems.
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3H
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Helmholtz Coils (Field Standards)
Lake Shore offers four Helmholtz coils for field standards: 2.5 in, 6 in, and 12 in diameter single axis, and the MX-2X-10 double axis coil. Standard field coil (field generation). Field strengths from ˜12 G to ˜30 G. Field accuracy of 0.5%. Field uniformity of 0.5%*. Single axis configuration with 2.5 in, 6 in, and 12 in diameter coils.
-
product
PAL Standard Pattern Generator
PG315P
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
product
Standard Air Capacitor Set, 1pF To 1000pF
16380A
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
product
BF-Series Standard Models
The E-DRIV® BF-Series standard models feature an adjustable RPM setting on the tool and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The BF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1W1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Standard 0.83 (23.50) - 2.85 (80.80) Battery Probe
CCA-004
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 470Overall Length (mm): 11.94
-
product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4C
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
product
Xytronic Three-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-30, RX-31 and RX-33
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4G
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard 4.10 (116.00) - 6.50 (184.00) Switch Probe
MSP-3C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 140Full Travel (mm): 3.56Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 2,140Overall Length (mm): 54.40Switch Point (mil): 30Switch Point (mm): 0.76
-
product
Standard Gain Horn Conical Lens antennas
Elva’s SLHA series of standard gain horn lens antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
product
Standards Tumble Dryer
TESTEX Testing Equipment Systems Ltd.
Standard Tumble Dryer, used for the test of drying process and of the drying procedures needed by other textiles, which are prescribed in the standard textiles test purposed household cleaning and drying procedures.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
CNC Machine Job Work
We are the leading organization to offer our precious clients an optimum quality CNC turning Job Works. Under this service we make use of CNC machines for milling, turning, finishing of various components.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4H
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard Transmitter
Tipix 2200
The TIPIX 2200 is a transmitter purposely designed for deep Induced Polarisation or Resistivity sounding investigations. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers. This entry-level instrument has been designed for an ease of use and for a good productivity together with a strong protection against misuse. This very robust device has proven to be reliable even in very cold weather (up to -40°C) or in wet environment. It is able to inject up to 2200W in the soil and to inject up to 13A, so that it is suitable, even on conductive soils, to measure resistivity and IP at medium range depths. It is powered by standard generator.
-
product
Standard & Custom Test Fixtures
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
product
Standard Tap Position Indicator
NMC,s Tap Position Indicator is a Microprocessor based specially designed instrument used to indicate the Tap Position of the Power Transformer with On Load Tap Changer.





























