Working Standards
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T75
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4G
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard Voltage 37 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard Air Capacitor Set, 1pF To 1000pF
16380A
-
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25C-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-C100-1
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
"Standard" RF Low Pass Filters
-
Coaxial Dynamics "Standard" line of RF Low Pass Filters offers several models to choose from at CW power ratings of 100 watts and 200 watts. These filters cover operating frequencies from 88 MHz to 400 MHz with less than 0.5 dB insertion loss and attenuation levels of 40, 50 and 60 dB.
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Standard 1.18 (33.30) - 3.25 (97.00) Battery Probe
BIP-1
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 16Test Center (mil): 150Test Center (mm): 3.81Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 250,000Overall Length (mil): 323Overall Length (mm): 8.20
-
Product
High Voltage Standard
HVS
-
The HVS uses precision matched resistors for high accuracy; it is a modified Park divider structure.
-
Product
Standard 4.10 (116.00) - 6.50 (184.00) Switch Probe
MSP-3C
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 140Full Travel (mm): 3.56Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 2,140Overall Length (mm): 54.40Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2SB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Standard DIP Socket with Solder Tail Bifurcated Contacts
Series 511
-
Standard DIP Sockets with Wire Wrap Bifurcated Contacts. Features: Standard DIP sockets are available with solder tail or wire wrap pins, all with bifurcated contacts. Consult Data Sheet No. 12005 for wire wrap pins. Aries offers these standard DIP sockets in more sizes than any other manufacturer.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HF-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Non Standard Connectors
-
C.C.P. Contact Probes Co., LTD.
With over 10,000 Designs, you could customize the product to achieve your spec!
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Standard Flexiforce Sensors for Force Measurement
FlexiForce
-
FlexiForce force sensors are ultra-thin and flexible printed circuits, which can be easily integrated into force measurement applications. These sensors are available for purchase in our online store.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard Voltage 37 Pin D-Type Cables - Calibration Cables for Pickering
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 37-pin D-type calibration port connector.
-
Product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensationof power factor in low voltage instalations.
-
Product
PathWave BenchVue AC Source Avionics Standard Test Software
BV0028B
-
Control your AC source and accelerate pre-compliance testing as per the avionics and military-standard requirements at ease.
-
Product
Super MUTT Deluxe Standard Edition
#9008-SE
-
Innovative Products of America
The Super MUTT places a load on the trailer's electrical circuits to identify wiring problems while providing remote control operation over both air brakes and lights. Built to facilitate a one-man testing operation, the Super MUTT reduces guesswork and inspection time to prevent failures that lead to expensive road calls and citations. The remote control allows for repetitive air brake actuation at each axle to reveal developing problems often missed by normal testing procedures.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-INS-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
GFS Primary Gravimetric Flow Standard
-
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
Product
Xytronic Single-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-20, RX-21 and RX-23
-
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.