Compensators
-
Product
Ion Chambers
-
0.2 to 5000 mR/hr, 5 Ranges• Temperature Compensated• Retractable 1000 mg/cm² Beta Shield• High Background Zero Capability• Proportional Audio Output
-
Product
Residential/Commercial Combustion Analyzer Kit w/ NOx Sensor/ Oil-Fired Appliances/ Printer
C165+NOILKIT
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Temperature Measurement Products
-
Precision devices and sensors used to track temperature, display thermal readings, and provide Automatic Temperature Compensation (ATC) for water quality and laboratory analysis.
-
Product
Residential Combustion Analyzer
C161
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C161 Residential Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and now adds a heat exchanger test. Prints to optional printer. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
HPLC Pumps
MX Class
-
Further applications include demanding metering and dispensing, as well as Sample Injection, Infusion, or Cone Wash for Mass Spectrometers. Standard fluid path material is Stainless Steel. With flow rates up to 10 mL/min, these pumps can tackle the majority of demanding laboratory applications.Features include pressure monitoring with automatic pressure compensation, Pulse Dampener, integrated Prime-Purge Valve, interactive keypad control, and complete PC control and status through RS-232, micro-USB 2.0, and Ethernet serial communications. Requiring minimal bench space for the performance, the MX Class will easily integrate into most workspaces.
-
Product
Closed Loop Hall Effect Current Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
Product
Portable Dissolved Oxygen Meters
-
Labodam portable dissolved oxygen meters are equipped with polarographic sensors to measure dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. Due to the portable nature of these instruments they can be used for various applications such as at water purification plants and waste water management plants for testing & quality analysis.
-
Product
Automatic Battery
BATLV1600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations. These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cablesof adequate cross section, and to supply the operation signal from suitable current transformer. FML capacitors and swichgear inside metal cabinet. Floor mounting.
-
Product
Ellipsometer
T-Solar™
-
The T-Solar ellipsometer combines the best photovoltaic measurement technology into a single system designed specifically for textured samples. Based on the establishedM-2000 rotating compensator spectroscopic ellipsometer, the T-Solar measures hundreds of wavelength across the UV-Visible-NIR.
-
Product
Length Network Cable Tester
SC-8108
-
1. Measure network cable length and determine the distance of breakage point.2. Check wiring error in 5E, 6E, coaxial cable, such as open circuit,short circuit, jumper wire, reverse connection .3. Portable unit with long battery life (wait-case 50 hours).4. Automatically time-delay shut off.5. Self-checking and automatically compensate any change in battery capacity or ambient temperature.
-
Product
Beer Refractometer
PA202X-799-803
-
Dual scale Digital Beer Refractometer for measuring Brix or Specific Gravity (D 60/60) of wort. These beer scales are temperature compensated specifically for wort.
-
Product
PRO+ 2-in-1 pH and Temperature Meter
MW102
-
The Milwaukee MW102 PRO+ pH meter has won fans around the world with its reliable, fast and simple operation as well as its toughness. Accurate to ± 0.02 pH with automatic temperature compensation. Ideal for use by brewers, wine makers, growers and other users with challenging pH measurement needs.
-
Product
Gas Filter Correlation CO Analyzer
Model N300
-
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
In Line Load Cell (200N-5000N)
100 Series
-
Miniature Threaded in Line Load Cells are strain gage based transducers with temperature compensation and excellent overall performance. This type measures tensile and compressive loads up to 5000N with better than ±0.25% non-linearity.
-
Product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
9 Inputs Satellite Multi-Switch
HJMS-900B (Stand alone)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
*8 satellite IF & 1 terrestrial TV inputs. *Built-in amplification circuit to compensate cable loss.* 13/18V.22KHz and DISEqC. *Suitable for residential multiple LNBs reception. *Sheet Metal Housing.
-
Product
Thin Film Based Thermopile Detector: 1 Channel
DR46 Compensated
-
A one-channel compensated thin-film thermopile in a TO-8 package. The active area and compensating element area are 4mm x 0.6mm each. Offers high output with very good signal-to-noise ratio. Internal aperture minimizes channel-to-channel crosstalk increasing sensitivity.
-
Product
Temperature Measurement IR Sensors & Detectors
DR34 Compensated
-
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.
-
Product
Capacitor for AC Filtering
PECA4 (900V)
-
Lifasa - International Capacitors, SA
These capacitors are especially suitable for applications where high levels of AC voltage are required. The design of this series has been optimized for the manufacture of high performance AC filters for compensation equipment with high pollution such as UPS or wind turbines
-
Product
Diode Power probe
-
The COMM-connect 3026 Diode based temperature compensated probe is designed for use with the COMM-connect range of Power Monitors. The probe will handle from 50µW to 100mW . Used with external couplers and the our measurement system application from 1W to 1MW, a high dynamic range can be configured. The 3026 Diode based probe gives excellent stable results along with the COMM-connect Power Monitor variants. This gives our customers a number of applications to monitor and control the last part of your RF network installation from transmitters to the antenna.
-
Product
Torsion Testing Machine
-
Unique ‘TALCON-CLAW’ Grips for Round and Flat SpecimensTorsional Speed of 0.1/0.2 RPMTorque Compensated MotorsMaintenance Free Gear Box Auto Range Selection with Range Selector Wheel (Optional)3 or 4 Torque Ranges for Higher Accuracy (Optional)Load-unload Capability Variable Speed Drive (Optional)
-
Product
Pressure Type Water Level Gauge
HR8003
-
HighReach Measuring & Controlling System Co.,Ltd
HR8003 high-precision pressure water level gauge is a hydrological instrument used for water level and water temperature measurement. It is developed through years of production technology and uses advanced mixed signal processing technology to overcome the shortcomings of traditional analog circuit modules. Full-scale digital Linear correction, full temperature zone digital temperature error compensation; compensation parameters are stored in non-volatile memory.
-
Product
UV Fluorescence Sulfur Dioxide Analyzer
Model T100
-
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel using NumaView™ Software, or via RS232, Ethernet, or USB com ports, either locally or by remote connection using the included NumaView™ Remote PC Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.The Model T100 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software.
-
Product
Residential Combustion Analyzer Kit w/ Printer/Case
C161KIT
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C161 Residential Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and now adds a heat exchanger test. Prints to optional printer. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Wet/Wet Differential Pressure Transmitter
647
-
Monitor differential pressure in air/liquid flow systems, HVAC automation, pneumatic systems and process control with the Series 647 Wet/Wet Differential Pressure Transmitter. Units are temperature compensated and provide a 4 to 20 mA output signal which can be interfaced with chart recorders, data loggers and computerized monitoring and control systems.
-
Product
Temperature and humidity outdoor, indoor probe
T3110
-
Programmable temperature and humidity transmitter is equipped with temperature and relative humidity sensors. Measured values are also converted to other humidity interpretation - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy. Degrees Celsius and Fahrenheit are user selectable. Transmitter contains a microprocessor based control circuitry in a durable plastic case with connection terminals and sensors in a filter with stainless steel mesh. Humidity transmitters is equipped with two galvanic isolated 4-20mA outputs. Configuration of outputs and output range are user adjustable. Large dual line LCD for simultaneous display of T+RH or other humidity interpretation is an advantage. Display is possible to switch off. Computerized design ensures temperature compensation of the humidity sensor and fail indication. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitters are designed for use in non-aggressive environment.
-
Product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
Temperature Input Module
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Inertial Measurement Units
IMU
-
Analog Devices inertial measurement unit (IMU) sensors are based on multiaxis combinations of precision gyroscopes, accelerometers, magnetometers, and pressure sensors. Our technology reliably senses and processes multiple degrees of freedom, even in highly complex applications and under dynamic conditions. These plug and play solutions include full factory calibration, embedded compensation and sensor processing, and a simple programmable interface.
-
Product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
-
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
Product
Passive Probe, 10:1, 75 MHz, 2-Pack
N2142A
Oscilloscope Probe
The Keysight N2142A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 75 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.