Compensators
-
Product
Temperature Data Acquisition
THERMES-USB
-
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
Product
MAX EC/TDS/NaCl/Temp Logging Bench Meter
MW170
-
The Milwaukee MW170 4-in-1 MAX EC/TDS/NaCl/Temp. Logging Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design and small benchtop footprint. It is accurate to ± 1% of reading for EC/TDS & Salinity with automatic, manual or no temperature compensation and a built in dedicated GLP key. Ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging EC/TDS/NaCL/Temp. measurement needs.
-
Product
Ka-Band Silicon SATCOM Tx Quad Core IC
AWMF-0109
-
The AWMF-0109 is a highly integrated silicon quad core chip intended for satellite communications transmit applications. The device supports four dual polarization radiating elements with full programmable polarization flexibility. The device provides 22 dB of gain per channel with an output power of +12 dBm per element per polarization. Additional features include gain compensation over temperature, temperature reporting, and Tx output power telemetry. The chip features ESD protection on all pins, operates from a +1.8 V supply, and is packaged in a 48 lead 6x6 mm QFN for easy installation in planar phased array antennas.
-
Product
pH Tester
148
-
The Elcometer 148 sensor has automatic temperature compensation, ensuring like-for-like measurements can be taken for meaningful comparison of the results.Simultaneously displays pH and temperatureMeasurement hold / freeze functionRecord maximum and minimum readings over a series of tests°C / °F user switchableWaterproof to IP57 and floats on waterAuto power off
-
Product
Compensation Block for Thermocouple Simulator Modules
40-965-912
Isothermal Termination Block
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
Product
Online pH Controller
LD-LOPC-A10
-
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
Product
Automatic Battery
BATLV1600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations. These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cablesof adequate cross section, and to supply the operation signal from suitable current transformer. FML capacitors and swichgear inside metal cabinet. Floor mounting.
-
Product
CO2 Concentration
H5524
-
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
-
Product
TMR Linear Sensors
-
MultiDimension Technology Co.,Ltd.
Linear sensor utilizes a unique push-pull half bridge composed of four unshielded TMR sensor elements. The unique bridge design provides a high sensitivity signal output that is linearly proportional to a magnetic field applied parallel to the surface of the sensor package, and it provides superior temperature compensation of the output.
-
Product
Paper Moisture Meters
-
A paper moisture meter measures the humidity of paper and paper products. Use of a paper moisture meter can prevent costly damages resulting from paper expansion or shrinking. A paper moisture meter determines paper moisture content based on either absolute humidity or relative humidity. Absolute humidity does not take into consideration temperature, while relative humidity relies on temperature and is expressed as a percentage of the total amount of moisture possible at the current temperature. Thus, many paper moisture meter devices feature automatic temperature compensation (ATC).For paper producers, paper manufacturers, paper mills and others in the pulp and paper industry, moisture and humidity control is essential, especially during the production process, as excessive moisture can lead to warming of the paper rolls. A paper moisture meter can be used to detect moisture streaks during the paper production process as well as to identify optimal drying times.Regardless of whether paper is stored in paper rolls in paper converting plants or stacked in sheets and paper bales in commercial printing warehouses, the porous surface of paper gradually takes in moisture relative to the humidity of the surrounding environment. This moisture can be problematic, as too much moisture can cause curling, buckling or the formation of waves in otherwise flat paper products. Moisture also can prevent inks, dyes, paints and coatings from covering and saturating paper properly during printing and processing.PCE Instruments (PCE) offers digital handheld moisture meter devices for measuring the moisture content of paper and paper products such as cardboard, paperboard, corrugated boxes, craft paper, wrapping paper, brown packaging paper, butcher paper, recycled paper, coated paper and more. Different paper moisture meter models utilize different paper moisture measuring techniques, performing moisture content tests of paper products via either destructive or nondestructive methods. Typically, a standard pinless paper moisture meter is nonpenetrating, thus allowing for the nondestructive measurement of paper water content.
-
Product
ELT STALKER Vector-finder
VF-121
-
The Vector-Finder Types VF-121 and VF 121A are unique in the Vector-finder series of direction finding antennas. They incorporate a proven design, electro statically shielded loop sensing element with modern solid state low noise analog and digital technology to allow detection and location of aircraft band signals. Both the VF-121 and the VF 121A incorporate a unique digital modulator which allows the user to more easily home-in on unmodulated carriers. Such cases occur at airports when transmitter may be accidentally keyed on during aircraft overnight layovers. The VF-121 is specifically designed to be used on airport premises where signal strengths are high. To compensate for very strong signals, an integral attenuator is also incorporated to allow the user to operate the unit close-in to aircraft. The VF-121A differs in that a high gain, low-noise preamplifier is utilized with the sensing element in order to hunt signals that may be weak or at a distance. The unit is ideally suited for the location of ELT transmitters in the field. Both units are tunable over the 118 MHz to 130 MHz aircraft frequencies and interface directly to the user’s aircraft band receiver or transceiver via the antenna jack. With the antenna system connected to the receiver, the user will hear the desired signal. If the signal is unmodulated, the digital modulator will generate a tone on the carrier. When the handheld unit is rotated about, an audible null on the received signal or the generated tone will be heard. This null aligns with the axis of the equipment case and represents the direction of the received signal. This direction may be read from the black dial compass mounted on the top of the enclosure. As the response is bi-directional, triangulation may be used to determine the true bearing when the true direction is not known.
-
Product
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle
865682-01
-
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
Product
Reference Temperature Sensors
-
AMETEK Sensors, Test & Calibration
Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.
-
Product
JTAG USB Controller
NetUSB-1149.1/E
Controller
The NetUSB-1149.1/E (4 TAPs) is an advanced USB 2.0 and LAN-based controller that can be used in the testing and/or in-system programming (ISP) of devices, boards, or systems compliant with the IEEE-1149.1 standard. The NetUSB-1149.1/E controller supports concurrent (gang) testing and in-system programming of CPLDs and Flash devices at TCK rates of up to 80MHz.The controller connects to the computer either through the USB interface or LAN interface for easy installation at nearby or remote locations. Other features include signal delay compensation for long cable lengths to the UUT, TAP signals, and GPIO discrete signals which are individually programmable from 1.25V to 3.3V, programmable slew rate control and pre-power up test for shorts between power and ground traces on the UUT.
-
Product
Thin Film Based Thermopile Detector: 3 Channels, Compensated
T34 Compensated
-
A three-channel compensated (6 element) thin-film thermopile in a TO-8 package. Each active area is 3.16mm x 0.4mm. Offers thermal compensation to minimize effect of sudden ambient temperature change. Internal aperture minimizes channel-to-channel crosstalk while increasing sensitivity.
-
Product
Power Detectors
-
Macom Technology Solutions Holdings Inc.
MACOM’s power detectors are broadband devices that have integrated low loss directional couplers and built-in temperature compensation circuits. These detectors provide an easy way to monitor the power of a signal travelling in a specific direction along a transmission line. These detectors are conveniently housed in miniature lead free plastic surface mount package. Typical applications include; Power monitoring and leveling in Point-to-Point radios, IMS, Radar, VSAT, EW, Aerospace and Defense Systems.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Robust Stability Meter
MR 1012 S
-
Owing to its high measuring rate, its compact and robust design, ist accuracy and long-term stability, the digital ohmmeter MR1012S can be used in applications with high requirements concerning the measuring stability and reliability. This is guaranteed by the integrating measuring method according to the quotient principle, the compensation of all thermoelectric forces and other offset voltages, as well as the suppression of interference voltages in the measuring and data lines induced e.g. by HF.
-
Product
Linearizers
-
Gain Shape Linearizer Amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run, or perhaps changing the input gain response to an MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
Product
SINE M-15-60 Sinusoidal Array
-
The reflective Sinusoidal Array SINE M-15-60 is similar to the M-13-60 (1X version) except that the range of spatial frequencies begins with 0.25 cycles per mm and extends to 20 cycles per mm. To compensate for the additional frequencies, the 3/16 cycles per mm area has been eliminated. Both arrays are imaged on Photo Paper.
-
Product
PRO High Range Conductivity Meter
MW302
-
MW302 is a Portable Conductivity High Range (EC) Meter with Automatic Temperature Compensation. This instrument has been designed to meet the Grower's need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. It is also a great meter for food, labs, and water treatment applications.
-
Product
Advanced Hydraulic Wedge Action Grips
2742 and 2743 Series
-
The Instron advanced hydraulic wedge action grips deliver controlled, constant gripping force using an external hydraulic supply across static and dynamic testing. They support capacities up to 600 kN (static) and 500 kN (dynamic), with interchangeable jaw faces for round or flat specimens. The design ensures jaw face positions remain fixed during gripping (eliminating preload), compensates for changes in specimen thickness, and is ideally suited for use with metals, composites, and plastics.
-
Product
TAP Extender
JT 2135
-
The JT 2135 allows TAP signals to be extended away from the base JT 2137 (classic pod) by up to 1 meter and retain full pod’s frequency specifications. The active circuitry inside the JT 2135 compensates for the TDO signal return time of the longer interface cable. Multiple JT 2135s can be implemented if a longer extension is required.
-
Product
Fluid Level Sensor
-
The output of the fluid level sensor is a voltage which changes in direct proportion to the level of fluid in the probe. The difference in permittivity between air and the fluid being measured changes the capacitance between the probe's two concentric tubes as the level changes. An RS232 connection to a PC allows the user to calibrate the fluid level and thermal drift compensation. The probe is factory replaceable, allowing the electronics to be re-used should the probe become damaged or if a new probe length is required.
-
Product
Field Machine
-
The Portable Field Machine is our most versatile full specification corrosion testing instrument. Its rugged construction and protective water resistance IP68 enclosure enables it to be operated at extreme locations throughout the world. This instrument takes laboratory precision outdoors to oil rigs, pipelines, concrete walls and just about anything that needs corrosion monitoring in situ. The potentiostat, ZRA, integral Frequency Response Analyser and Sweep Generator are exactly as provided in the laboratory Gill 8 model ensuring the most accurate testing available. The choice of tests is not limited; the AC, IR Compensation and DC tests plus the Sequencer and Analysis that are supplied with this field instrument are the same as supplied with the laboratory instruments.
-
Product
Cable Electric Resistance Tester
MR 270 C-A
-
The MR270C-A is specially designed for electric resistance measurements in cable industry applications and inductive loads (transformers, motors). It is perfectly fit both for measuring the meter resistance in connection with a corresponding resistance measurement holding device or for final acceptance control of power cable reels. In the case of cable reels, which often have a cable length of several kilometers, both the compensation of the inductive component and the ability to perform measurements in the presence of high noise levels are important. This also applies to the winding resistance of transformers and motors.
-
Product
Flue Gas Analyzer (Instrument Only)
C160
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C160 Residential Combustion Analyzer is instrument only, easy to use with a rugged design, multiple sensor protections and altitude compensation. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Dual Piston Pumps for Low Pulsation Requirements
ReaXus LD Class
-
The versatile LD Class consists of dual-headed, positive displacement piston pumps, delivering unmatched performance for analytical, flash, and small-scale preparative chromatography applications.The pumps are designed for high flow rate accuracy and low pulsation required for Analytical Liquid Chromatography (HPLC). Standard fluid path materials are Stainless Steel, PEEK, in addition to optional Hastelloy. Other available features include jacketed heads for temperature controlled processes. With 12 mL/min, 36 mL/min, and 100 mL/min versions, reaching pressures up to 6,000 psi, these pumps will meet the performance requirements of demanding HPLC needs.The high performance linear cams, along with automatic pressure compensation, provide precise flow rates for very accurate high pressure and low pressure gradients. Standard features include an integrated Prime-Purge Valve, Pulse Dampener, interactive keypad control, and complete PC control status through RS-232 and Micro USB 2.0 ports. The LD Class provides the precise flow and low pulsation for the most challenging separations.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Light Compensation Capacitor
CBB80
-
Designed for lighting applications such as fluorescent lamps,high-pressure mercury vapor lamps,sodium lamps,and metal halide lamps. The capacitors are used for power factor compensation of transformers and magnetic ballasts in lamps with a frequency of 50Hz or 60Hz,which makes the power factor to achieve cosφ 0.9. The temperature





























