Thermocouple Calibrators
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm
CK520A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Time to Amplitude Converters and Calibrator
-
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
Product
Pressure Calibrators
-
AMETEK Sensors, Test & Calibration
Our pressure calibrators offer a wide variety of features, accuracies, and pressure ranges. Included are intrinsically safe percent of reading calibrators, reference data recorders, wide-range dual sensor calibrators, and calibrators with built in pressure pumps. Many of our calibrators also offer current measurement, voltage measurement, 24 volt loop power supplies, and even complete systems with pressure pumps and calibration software. In many cases, one handheld calibrator can replace multiple instruments, reducing ongoing recalibration and maintenance costs.
-
Product
DC/10 MHz 50 GHz USB Thermocouple Power Sensor
U8487A
-
The U8480 series is Keysight's first power sensor with the capability to measure down to DC (only applicable for U8481A/85A). Now, with an expanded frequency range up to 50 and 67 GHz, the U8480 series allows you to make fast and accurate high frequency power measurements in applications ranging from PNA/MXG calibration to high volume manufacturing.
-
Product
CableEye Tester Calibration Verification Board | Cable & Harness Tester
CB50
-
Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently.
-
Product
Calibration Services
-
OMEGA offers a broad range of calibration services, with primary and secondary NIST traceable standards for calibrating temperature, infrared humidity, pressure, flow, and force products.
-
Product
Gauge Type T Thermocouple Wire
W-TW-30
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Transducer Calibration
-
When it comes to finding the perfect transducer calibration system, look no further than MB Dynamics. Our Calibration Systems offer an extensive range, from the Win475-Basic, the trusted calibration solution for the United States Air Force; to the first of its kind Win475-TS, which measures a transducer’s transverse sensitivity. No matter what your needs, you’ll find the calibration equipment that works for you.
-
Product
Multifunction Field Calibrator & Communicator
MC6-Ex
-
The MC6-Ex is an intrinsically safe field calibrator and communicator. It is ATEX and IECEx certified and can be used in all hazardous zones / divisions. The MC6-Ex includes a field communicator for HART, FOUNDATION Fieldbus and Profibus protocols. Each calibrator is delivered with a traceable, accredited calibration certificate as a standard. t is a documenting, multifunction calibrator and communicator that offers calibration capabilities for pressure, temperature and various electrical signals.
-
Product
Dimensional Calibration
-
123 BLOCKS ANGLE BLOCKS BALL BAR BORE GAGE CALIPERS CHAMFER GAGES CMM'S COATING THICKNESS GAGES CYLINDER PLUGS DEPTH GAGES GAGE BLOCKS GO-NO-GO GAGES HARDNESS TESTERS HEIGHT GAGES INDICATORS LENGTH STANDARDS LEVELS MICROMETERS OPTICAL COMPARATORS PARALLELS PIN GAGES PROFILOMETERS RADIUS GAGES ROUGHNESS SPLINES THREAD RINGS THREAD PLUGS
-
Product
Calibration and Verification Kits
-
Flann offers a wide range of calibration and verification kits to suit many applications and price points. Compatibility with the vast majority of current and legacy VNAs can be provided. Additionally full customisation of our kits is possible to suit your requirements.
-
Product
Multifunction Calibrators
-
Many of the calibrators we offer are multifunctional calibrators, that is because then you don’t need to carry so many devices and also don’t need to recalibrate several devices. For us the “multifunctional” means a calibrator that can measure and generate electrical, temperature and pressure signals.
-
Product
Thermocouple Power Sensors
N8481H
-
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
146907-01
-
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
-
Product
Multichannel Acoustic Calibrator
WK-8
-
Multichannel Acoustic Calibrator Type WK-8 is designed for calibration of multichannel acoustic measurement systems equipped with a half-inch measuring microphones in the field conditions.
-
Product
K-Type Thermocouples Wire, Fiberglass (32deg F to 900deg F) 2 m
745690-K002
-
K-Type Thermocouple, 32°F to 900°F Temperature Sensor - The K-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the K-Type Thermocouple and acquire synchronized temperature data in units of degrees. The K-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Test & Calibration
-
Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0). In addition to assurance of measurement accuracy, accreditation ensures traceability to known standards, provides international acceptance of measured values, and is important for compliance purposes for your own ISO/IEC certifications. Our state-of-the-art, ISO 17025 accredited calibration laboratories in San Diego, California offer a range of test and calibration services including:
-
Product
Light / Lux Meter, Calibrated w/Data, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL D
-
The 72-7250 CAL D from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
Calibration Wheel
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Calibration wheel is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
Sound Level Calibrator
521
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Cryostat Calibrators
-
Electronic Development Labs, Inc.
Specialized, low-temperature, passively cooled, or liquid nitrogen-based apparatuses designed to calibrate temperature sensors (RTDs, thermocouples, PRTs) at cryogenic levels.
-
Product
Calibrated Pocket Magnetometer
M 25
-
Instruments available in 8 different, Full Scale, Gauss Ranges.
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Instrument Calibration Services
-
Instrument Calibration ServicesCalibration is a fundamental step in the process of measurement. It ensures that the instrument used for testing accurately indicates the required measurement parameter and that the instrument is performing to its specification.
-
Product
Scientifically Calibrated Audio Clips
AudioRef™
-
AudioRef is a package of scientifically calibrated audio reference clips that enable professionals to accurately set up and evaluate audio monitoring equipment.
-
Product
Air Data Calibration
-
Fluke calibration offers digital pressure monitors, air data calibrators and laboratory standards for air data pressure range calibrations. Each of these systems feature pressure ranges, measurement units and features specific to calibrate air data test sets and RVSM compliant air data instruments. Models include 2468 Ruska and ADCS-601 DHI primary level standards; 7750i Ruska air data controller/calibrator and RPM4-AD DHI reference pressure monitor.
-
Product
Calibration & Testing Unit for AC & DC Meters
-
Supreme Instrument Laboratories
Calibrator for calibration and testing of A.C. Milliammeters, Ammeters, Voltmeters, and D.C. Microammeters, Milliammeters, Ammeters, Millivoltmeters and Voltmeters having following technical specification
-
Product
Thermocouple Bench Selector Switches 6 or 12 Way IEC, ANSI
-
A 6 or 12 way selector in a moulded housing with aluminium front and rear panels. The rear inputs are switched via a front mounted rotary selector switch to the single output socket. Internally wired with thermocouple compensating cable and available with IEC or ANSI thermocouple types K, J, T, N & R/S.
-
Product
Automatic Cleaning and Calibration
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Fully automatic process monitoring in combination with the analysis measuring system Protos and the retractable housings SensoGate or Ceramat. Highly accurate measurements even under difficult process conditions such as high pressure, high temperatures and high levels of impurities.
-
Product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
-
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.





























