Thermocouple Calibrators
-
Product
Electromechanical Calibration for Transducer
ELCS-500
-
Jinan Testing Equipment IE Corporation
The electromechanical calibration system is specially designed for the calibration of transducers. The calibration for transducer can calibrate the load cell accuracy within +/- 0.5%.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
Machine Calibration and Optimisation
-
Renishaw's laser interferometer and ballbar measurement systems assess, monitor and improve the static and dynamic performance of machine tools, co-ordinate measuring machines (CMMs) and other position-critical motion systems.
-
Product
Monitor Calibrator
hueyPRO
-
It's all about the color. Color in your photos, color in your designs, color online and more importantly, color on your display. World's first built-in ambient light sensor enables consistency never seen before in any lighting condition.
-
Product
Optical Power Meter W/6 Wavelength Calibrating Spots
-
With six wavelength calibrating spots (980nm, 1310nm, 1490nm, 1550nm, 1590nm and 1610nm), refined design, easy operation, linearity or non-linearity display, SC connector, the MXOPM26-50 hand-held optical power meter can be used for direct optical power measurement as well as relative measurement of optical link loss. It’s an essential test instrument in Optical Communication systems, CATV systems, construction and maintenance applications and more.
-
Product
Portable Protection Test Set and Calibrator
CMC 430
-
The CMC 430 is the preferred choice for test engineers in cases where excellent transportability is needed and three currents up to 12.5 A or six voltage outputs are sufficient. Its low weight of just 8.7 kg / 19.2 lbs, and robust design with its edge protection predisposes the device to every outdoor and indoor use.
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
Product
Force Calibrating Machines
-
Morehouse Instrument Company Inc.
Morehouse Universal Calibrating Machines (UCM) are an easy to use, cost-effective, hydraulic force calibration system that lasts for generations. UCMs built in the 1950s are still operating today! The UCM can be used to calibrate both tension and compression instruments in accordance with ASTM E74, ISO 376, and other internationally recognized force standards.
-
Product
Light / Lux Meter, Calibrated w/D & U, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL DU
-
The 72-7250 CAL DU from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Dry Block Calibrator
-
We offer temperature dry blocks in different models; we offer easily portable and fast temperature blocks for field use and high accuracy temperature blocks for laboratory use.
-
Product
K Thermocouple Immersion Probe
TP651_TP652
-
Immersion "K" Type thermocouple probe. °C max: 1200. Response time: 6 s.
-
Product
Temperature Calibration System
-
Thermal Engineering Associates, Inc.
Systems for determining relationship between temperature-sensing junction voltage versus junction temperature of diodes, integrated circuits and thermal test die. Provides internal current sources, voltage measurement to 1 mV, and temperature measurement to 0.1ºC. 16-channel capability with optional printer and serial port data output.
-
Product
Hopper Ash Level Thermocouple System
HALT
-
The Hopper Ash Level Thermocouple (HALT) System is a preventative maintenance and safety tool that continually monitors the levels of ash within a hopper. As the hopper plugs and the ash levels increase, the thermocouples will become insulated from the boiler heat by the ash. Low temperature readings trigger visual and digital alarms which indicate that the hopper has plugged.
-
Product
Qualified Hermetic EGT Thermocouple Upgrade
-
FIT-IT & FORGET-IT Eliminate Exhaust Gas Temperature (EGT) thermocouple concerns with AMETEK's new EGT thermocouple product offering for Frame turbine applications. AMETEK has worked closely with the turbine OEM to design and engine test this thermocouple as a direct replacement and upgrade for all new and existing EGT thermocouples. The new EGT thermocouples are qualified and meet all design specifications.
-
Product
PXI Thermocouple Simulators
-
Our PXI Millivolt Thermocouple Simulator modules provide 32, 24, 16 or 8 channels of accurate low sources. They are ideal for the simulation of thermocouples and can be used for sensor emulation in ECU testing. The channels can be operated with one of three voltage ranges covering most thermocouple types. We can also supply connection solutions allowing the easy integration of the Thermocouple Simulator into your test system.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Intelligent Pressure Calibrator
-
Huaxin Instrument (Beijing) Co., Ltd
Here at Huaxin, we offer a selection of HS602 and HX601B intelligent pressure calibrators. They are high pressure, single range digital pressure calibrators with HART communication capability. Composed of high precision measurement chip, 24V DC power supply, battery charging protection circuit, HART communication module and intelligent digital pressure module, these two pressure calibrators provide a pressure calibration solution for gauges, transmitters, and switches over a wide pressure range.
-
Product
Current Probe Calibration Fixtures
-
Calibration fixtures are used for calibration of Coupling Loss/Transfer Impedance of current probes and BCI probes, as well as for the calibration of test levels for conducted immunity/susceptibility tests using BCI probes.
-
Product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (f)
CK058F
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Thermocouple Thermometers
-
Polarity: Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 270g including batteries.
-
Product
Calibration Management Software
-
Regardless if you are a commercial calibration company performing services for your clients or a in-house calibration organization working to meet your internal customers requirements, Qualer provides companies best in class functionality with our Calibration Management Software for the management and performance of calibrations and maintenance. Qualer’s Calibration Management Software Cloud infrastructure enables calibration and documentation to be processed in real-time, increasing efficiencies and productivity, while reducing costs.
-
Product
PXI Isolated Millivolt Thermocouple Simulator - 24 Channel
41-761-002
-
The 41-761-002 is a low voltage 24-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
Product
Temperature Calibration Equipment
-
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.
-
Product
Calibration Foils Sets
990
-
The Elcometer 990 Calibration Foil Sets are ideal for use in the laboratory, on the production line or on site.
-
Product
16 Inputs Temperature Data Logger – Thermocouples
HD32.8.16
-
Rugged data logger with 16 inputs for K, J, T, N, R, S, B and E type thermocouple
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Oscilloscope, Calibrated, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A CAL
-
The 72-8710A CAL from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides a complete set of trigger modes including edge, pulse, alternate and storage modes including set-up, wave, bitmap. It has a 7 inches wide screen LCD display and supports plug and play USB storage device. Communication with and remote control of computer through the USB device.
-
Product
Bench Power Supply, Calibrated, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL
-
The 72-2690 CAL from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).





























