Physitemp Instruments
Physitemp Instruments Inc is an electrical/electronic manufacturing company.
- 800.452.8510
973.779.5577 - (973) 779-5954
- 189 Sargeant Avenue
Clifton, NJ 07013
United States of America
-
Product
Skin Surface Probe
SST-1
-
The SST-1 skin surface temperature probe for humans, to be taped on is re-useable and has a fast response time.
-
Product
Animal Temperature Control
TCAT-2AC
-
This version controls only AC powered heating or cooling devices such as a heat lamp. It is the least costly.
-
Product
General Purpose Probe
HT-2
-
HT-2 ''Workhorse'' General Purpose Probe - designed for temperature measurement of liquids, gases and semi-solids. Plastic handle with straight 9'' stainless shaft. Not good for surface temperatures. Maximum temperature 400°C, Time constant 0.5 Seconds. 5 foot lead. Not isolated.
-
Product
Thermalert Clinical Montoring Thermometer With Analog Output
TH-5/AOP
-
The TH-5?AOP is one of our most economical precision thermometers in the Physitemp product line. The TH-5/AOP offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-5 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
Product
Thermocouple Extension Lead
EXT-6
-
The EXT-6 - 6 foot, Type T Thermocouple Extension Lead. Flexible vinyl covered.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
General Purpose Probe
HT-1
-
HT-1 ''Workhorse'' General Purpose Probe - designed for temperature measurement of liquids, gases and semi-solids. Plastic handle with straight 3'' stainless shaft. Not good for surface temperatures. Maximum temperature 400°C, Time constant 0.5 Seconds. 5 foot lead. Not isolated.
-
Product
Sensor Six-Pack
PT-6
-
PT-6 Sensor Six-Pack - For multi-point temperature measurements. Inexpensive, Flexible. Welded sensor beads, tough kapton insulation. Diameter is .029''. Maximum temperature 350°C, Time constant 0.01 Seconds. 5 foot lead. Not isolated.
-
Product
Multipurpose Thermometer-Rechargeable
BAT-10R
-
This versatile thermometer has a wide temperature range and can be used in applications as diverse as cryogenic measurements for blood banking and cryosurgery, skin temperature measurements in exercise experiments, liquid measurements in spectrophotometer cuvettes, melting points of plastics and all types of animal and insect temperature measurements.
-
Product
Temperature Data Acquisition
THERMES-USB
-
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
Product
Needle Microprobe
MT-26/6HT
-
Fast-response 26 gauge needle probe, (needle length is 6 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Animal Temperature Controller- Dual Feature
TCAT-2DF
-
This is a combination version which includes both and AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low noise DC output for heating pads. This version allows you to controls a variety of different loads.
-
Product
Temperature Data Acquistion
THERMES-USB RF
-
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.















