Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
K Thermocouple Surface Probe
TP745
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
CAN PT MiniModule evo
-
CSM offers these modules for temperature measurements with increased accuracy requirements compared to thermocouples. PTMM evo modules allow high-precision temperature measurements with either PT100 or PT1000 RTD elements.
-
Product
Chromel, Type K (°C), Thermocouple Contacts
-
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
Thermocouple Data Logger
TGU-4550
-
The Tinytag Ultra 2 Thermocouple data logger uses a thermocouple sensor for the cost-effective monitoring of temperature in a wide variety of applications.
-
Product
Data Acquisition Systems
-
Encore Electronics manufactures a wide range of analog signal conditioning equipment, including strain gage and pressure amplifiers, frequency-to-voltage converters, thermocouple isolation amplifiers and anti-aliasing filters.
-
Product
Thermapen
Super-Fast ®
-
The Super-Fast ® Thermapen has been a favorite among restaurant chains, health inspectors and quality managers worldwide. Hundreds of thousands are in use. The clever fold-away probe and the simple pocket design replace more costly and bulky handheld thermometers while using the same professional thermocouple technology. This new generation Thermapen introduces a robust, splash-proof design with molded-in seals to protect the thermometer from wet hands and kitchen splashes.
-
Product
Dual Temperature
-
The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters.
-
Product
3-Slot Data Acquisition Mainframe With GPIB, Three 20-Channel Multiplexer Modules, And BenchVue DAQ Software
DAQ973MBX
-
The DAQ973MBX Best Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, three 20-channel DAQM901A multiplexer modules, and a BV0006B BenchVue DAQ software with a KeysightCare software support subscription. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2-and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning measures thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance36-month node-lock BV0006B BenchVue DAQ software license with KeysightCare software support subscription
-
Product
Digital Temperature Switch
TCS
-
Monitor and control temperature in heating and cooling applications with the Series TCS Thermocouple Switch. The Series TCS offers a wide temperature range, two selectable alarm set, and an internal buzzer indicating alarm condition or error
-
Product
4-CH 24-Bit Universal Input USB DAQ Modules (OEM Version Available)
USB-2401
-
The USB-2401 is a 24-bit, 4-channel simultaneous-sampling universal input USB DAQ modules featuring built-in signal conditioning circuitry, providing direct measurement of commonly used sensors including current output transducers, thermocouple, RTD, load cell, strain gauge, and others. Individual channels can be programmed to measure different signal types. The USB-powered USB-2401 is equipped with removable screw-down terminals for easy device connectivity, and the included multi-functional stand fully supports desktop, rail, or wall mounting.
-
Product
7-Ch Thermocouple Input Module With Independent Input Range
ADAM-5018P
-
Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 HzSampling Rate: 10 samples/sec. (total)High Common Mode: 2000 VDCIsolation Voltage: 3,000 VDCFault and Overvoltage Protection: Withstands over voltage up to ±35 VCMR @ 50/60 Hz: 92 dB minInput Impedance: 20 MΩ. (Build-in 120 Ω Register for Current Input)Built-in TVS/ESD ProtectionFilter function: YesChannels: 7 differential with Independent Input Range
-
Product
MINITAURs - 8-channel universal DAQ system
MINITAUR-S
-
Mixed signal 8-channel data acquisition system and multichannel data logger with cutting-edge technology at an attractive price. Universal analog inputs can accommodate various signals like strain gage, IEPE, voltage, current, RTD, thermocouple, and LVDT.
-
Product
K Thermocouple Air Probe
TP744
-
Thermocouple Type “K” air probe. Tolerance according to IEC 60584-2 standard.
-
Product
Transmitters
-
Transmitters are used for industrial applications to convert process signals into standardized isolated output signals 0-10V or 0 / 4-20mA. In addition to the process signals, various sensors can also be connected, e.g. Pt-100, thermocouples, potentiometric sensors, inductive, capacitive and optical initiators, resistors, etc. The transmitters are supplied with 230VAC or 24VDC and housed in a DIN housing for 35mm rail mounting.
-
Product
MAX31855 T-Type Thermocouple Arduino Shield
SEN-30004-T47
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino.
-
Product
Thermocouple Temperature Data Logger
TCTemp2000
-
The TCTemp2000 is a thermocouple temperature data logger perfect for applications requiring instant remote readings of temperature. The 8-button keypad and large LCD provide convenient access to current data and data logger setup. This data logger has an internal temperature sensor and one external input for J, K, T, E, R, S, B and N type thermocouples. Additionally, memory and battery levels, external power status, sampling and recording status are shown on the LCD.
-
Product
Basic Quad J-Type Analog Thermocouple Amplifier
SEN-30103-J1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
High Temperature Sensors
-
Thermocouple with miniature Ceramic Plug & Ceramic Socket & Ceramic Kiln Thermocouples For High Temperature
-
Product
Soil Temperature Sensors
-
Soil temperature sensors come in a variety of designs using thermistors, thermocouples, thermocouple wires, and averaging thermocouples. The electrical signals transmitted from the sensors to our dataloggers can be converted to different units of measurement, including °C , °F, and °K. Our dataloggers are also capable of measuring most commercially available soil temperature sensors.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Ammeter
AC Rectifier Type Coil Meter
-
measures the alternating voltage and current with the help of rectifying elements and permanent magnet moving coil type of instruments. However the primary function of rectifier type of instruments work as voltmeter. Now one question must arises in our mind why we use rectifier type of instruments widely in the industrial world though we have various other AC voltmeter like electrodynamometer type instruments, thermocouple type instruments etc? The answer to this question is very simple and is written as follows.
-
Product
PXI Isolated Millivolt Thermocouple Simulator - 8 Channel
41-761-004
-
The use of two wire outputs and isolation from ground ensures that the 41-761 can be used to accurately simulate low voltages even in the presence of common mode voltages in the system. Each Vcold connection is independent permitting the 41-761 to be connected to multiple cold junctions.
-
Product
Temperature Measurement System
Spider-80Ti
-
The Spider-80Ti is a front-end from the Spider-80Xi hardware platform that enables temperature measurement. Spider-80Ti supports temperature measurements from Thermocouples and RTD (Resistance Temperature Detector) sensors.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Temperature and Process Controllers
-
The ATR121 Temperature Controller is a 3 digit display PID controller with up to 2 relay outputs, Solid State Output and an option to be a Modbus RS485 Slave device.The ATR141 Temperature Controller is a 4 digit PID controller and Panel Meter which can display up to 3200°F with an S Type Thermocouple. The ATR141 can have up to 2 relays, a Solid State Output and an option to have a Modbus RS485 output.
-
Product
Thermocouple Thermometer Data Logger
HD2108.2
-
Thermocouple thermometer with logger. Input for K, J, T, R, N, S, B, E type probes with miniature connector. Maximum, minimum, average.
-
Product
Temperature Data Acquistion
THERMES-USB RF
-
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.
-
Product
24-Ch RS-485 T/C Input Module 24-Ch Ethernet T/C Input Module
ADAM-518E/518
-
24-channel thermocouple input reduces module count, saving wiring and cabinet spaceSupports widely used thermocouple types for general industrial and environmental applicationsThermocouple type and input range can be easily configured using ADAM Utility with no programming requiredDelivers 16-bit resolution and ±0.5 °C CJC accuracy for stable and precise measurementsWide temperature measurement range supports a variety of application needsDual LAN ports support Ethernet daisy-chain connection to simplify wiring and reduce switch costs (ADAM-518E)Auto-bypass keeps network connection during power loss, reducing downtime and maintenance costs (ADAM-518E)Built-in Graphic Condition Logic (GCL) allows simple control logic to run directly on the module without a PLC or PC (ADAM-518E)
-
Product
Thermocouple Contact, Receiver, Copper, Type T (°C)
610113168
-
Primary mating contact 610113169.
-
Product
Instrumentation Tutor
-
Unitech Scales And Measurements Pvt. Ltd
This comprises of temperature and speed using different methods. RTD, thermistor and thermocouple are used as sensors with digital temperature indicator to measure temperature. A small water kettle is supplied as a temperature source upto 100°C. Glass bead thermometer is used as standard temperature measurement source to conduct the experiment. Magnetic and photo reflective sensors are used to measure speed. A FHP motor with speed regulator is used as speed source. To the shaft 60 teeth tone wheels are fixed to generate pulses.