Product
AC Voltage Proving Units
HLV-1
-
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
Product
Proving Unit
PRV240
-
The Fluke PRV240 provides a safe method to verify that your electrical test tool is operating properly before and after you conduct any live tests. The concept of “Test Before Touch” (TBT) involves testing your meter against a known live source before and after the actual measurement.
-
Product
Proving Unit& Calibrators
-
Shanghai Beha Electronics Co., Ltd.
Calibration box is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.
-
Product
Proving Units
-
Designed to suit a range of applications in the electrical contracting power utilities and industrial engineering sectors Seaward proving units are both self-powered and self-testing avoiding the need for a known supply point or bulky test equipment.
-
Product
H.V. Proving Unit (DCV)
2713 PU
-
Standard Electric Works Co., Ltd
● Designed to proof: -Phasing sticks. -High voltage detectors (contact type only, not to be used with non contact proximity detectors.) -High voltage and voltage testers.● Battery operated.● Led indicates when power is “ON”.● Small and hand-held.● Quick connection with normal 4mm test leads.
-
Product
Proving Unit & Voltage Tester Kit
DLPK1
-
Touch electrode for Quick testing of fused leads Optical and acoustic continuity Indication Low battery indication A portable, battery powered Proving Unit for testing Two Pole Voltage Testers up to 690V Continuity Tester for testing: Fuses, Fused test leads etc
-
Product
Electricians' Accessories
-
A selection of voltage detectors, proving units, test leads, certificate books and a DVD, which make it that bit safer and easier to get the job done.
-
Product
Test Voltage Indicators
PRV240FS
-
Verify your test tool works without unnecessary exposure to shock and arc flash. Make the process easy by using the PRV240FS Proving unit. Verifying that your T6 electrical tester is working properly reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification before tests are performed.
-
Product
Proving Units for High Voltage Testing Equipment
-
A high quality range of proving units provide the important role of verifying the safe operation of high voltage potential indicators used by power engineers, maintenance personnel and service engineers. The proving units are essential tools for testing HV equipment before and after use.
-
Product
AC Voltage Proving Units
HLV-2
-
Standard Electric Works Co., Ltd
The AC Voltage Detectors and AC Voltage Testers utilized to determine if the devices under test are functionally working. They are not a calibrator and cannot be utilized for calibration.
-
Product
PXI 30A Fault Insertion Switch 6-chan 2-bus
40-191-012
Fault Insertion Unit
The 40-191-012 is a PXI fault insertion switch using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
Source Measure Unit
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXIe-4147, 4-Channel, ±8 V, 3 A Precision PXIe Source Measure Unit
786888-01
Source Measure Unit
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing engine, you can synchronize SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4147 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
4- Channel PXI Source Measure Unit (SMU)
GX3104
Source Measure Unit
The GX3104 is a precision 3U PXI module that forces and senses both voltage and current over a range of ±20 V and up to ± 1 A ( channel 1) with channels 2- 4 capable of supplying up to 500 mA. Total available output current from the module is 1A. The four channels are electrically isolated from the PXI power supply and share a common, isolated ground.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-212
Fault Insertion Unit
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
Fault Insertion Unit
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXI Source And Measurement Unit Family
PXS840x
Source Measure Unit
The PXS(e)840x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
Source Measure Unit
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
USB Modular Source Measure Unit
U2722A
Source Measure Unit
The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
Fault Insertion Unit
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXIe Precision Source/Measure Unit, 1.25 MSa/s, 10 fA, 210 V, 315 mA
M9601A
Source Measure Unit
M9601A PXIe precision SMU is the industry-first precision PXIe SMU enabling faster precise measurement from DC to 20 μs pulse up to 210 V/315 mA with the best-in-class 10 fA resolution and low noise.