Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3B
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
110 GHz Frequency Extender
N5293AX51
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Capacitance Standard
SCA Series
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H180-1
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-C
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
product
Decade Resistance Substituter Lab Standard
HARS-LX Series
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
product
Real Time MM-Wave Frequency Analyzers up to 180 GHz
When millimeter-wave applications came into many domains of human activity, a need for precise measurements of signal frequency spectrum has become critical. This need is quite understandable when, for example, it concerns to exploring extraterrestrial radio-sources or micro/mm-wave background emission in radio-astronomy, or measuring chemical composition of the atmosphere through the molecular emission of different its components, plasma diagnostics or many military applications.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2G40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard Normally Open
Is an optically coupled element that combines a GaAs infrared LED on the input side with anormally-open MOS FET on the output side to realize an excellent cost performance.The small, thin package and high sensitivity of this element makes it ideal for battery-driven mobile devices, and its small offset voltage at power-on and good linearity are also make it suitable for controlling micro analog signals.
-
product
NF-Series Standard Models
The E-DRIV® NF-Series standard models feature an adjustable RPM setting on the tool and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
product
PXI Standard Programmable Resistor Modules
Pickering's PXI Standard Programmable Resistor Modules include fully programmable resistor and potentiometer modules for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Modules can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection. For applications with more demanding accuracy and resolution requirements, consider our Precision Programmable Resistor Modules .
-
product
Double Voltage Double Frequency Generator Setup
DVDF
This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.
-
product
Low Frequency Generator
LFG-2500
• tracing – finding the route and burial depth of the underground utilities;• fault location – pinpointing phase-to-sheath and interphase short-circuit faults;• cable identification – identifying a correct cable in a bunch.
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Standard Gain Horn Conical Lens antennas
Elva’s SLHA series of standard gain horn lens antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
product
Dynamic Frequency Selection
MET is a leader in performing DFS testing on a variety of WLAN products for FCC, ISED, EU and Japan requirements.Many countries require wireless devices operating in unlicensed 5 GHz bands to have the capability to detect interference with other technology sharing the spectrum (such as military and weather radar systems) and automatically switch over to another frequency.
-
product
Solution Standard Reference Materials
NCS Testing Technology Co., Ltd.
Solution Standard Reference Materials by NCS
-
product
Audio Frequency Oscillator
PD-5
2.5- 100 volt output6 position output voltage selectorCompatible with all "Mark" receivers (Mark II, III, IV, V)Pulse "Identifying" signalBattery charging circuit built-inLED impedance meter
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
AC Power Supply and Frequency Converter
P Series
The P Series AC Power Supply and Frequency Converter for your test bench or test rack delivers clean regulated AC power in a (2U) 3.5" high and (3U) 5.25” high bench top unit that easily converts to rack mount, for far less cost than competitive models.
-
product
PAL Standard Pattern Generator
PG315P
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Frequency To DC Isolating Transmitter
Model TWF / TWF2
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 ° C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
product
HF Frequency Counter LXI, GPIB/IEEE48
53210A
For fast and accurate frequency and time-interval measurements, you need reliable devices in research and development. The Keysight 53210A HF frequency counter meets the requirements with its high accuracy, bandwidth and speed. Depending on the application and budget, choose one of the three available models. The connection to the PC is via USB, Ethernet/LXI or via GPIB.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1J-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25UN-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T1-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Dual Frequency 900 kHz & 2250 kHz 2D Imaging Sonar
BlueView M900-2250-S 130/45-Mk2
The dual frequency M900/2250-S 130/45-Mk2 is a new configuration of the leading BlueView M900/2250 optimized for superb image quality in challenging shallow water environments. The 900 kHz offers high-resolution long range navigation, object detection, and obstacle avoidance, while the 2250 kHz provides ultra-high resolution at close range. ROV navigation, diver hand held, hull inspections, structure inspections, diver monitoring, and search and recovery are a few applications that benefit from the dual-frequency’s imaging capabilities. All M Series sonar operate while in motion or from a stationary position delivering real-time imagery and data.
-
product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1V1S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Frequency Converters
Analytic Systems' Single and 3-Phase Sine-Wave Converters deliver output power ranging from 250 VA to 5000 VA. Our Frequency Converters also generate nominal output voltages of 115 VAC or 220 VAC, at frequencies of 50, 60 or 400 Hz. A broad range of input voltages are available.





























