Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
product
WR5.1 Frequency Extension Solution, 140-220 GHz with VDI Extender Modules
CobaltFx 140 to 220 GHz
CobaltFx cost-effective millimeter wave frequency extension system allows you to build a scalable and affordable 5G testing solution.
-
product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1W1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
Standard Clamp Meters
For extreme temperatures, choose an analog clamp meter that can measure amps and volts without needing batteries.
-
product
Standard 1.27 (36.00) - 2.94 (83.35) Battery Probe
CCA-003
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 670Overall Length (mm): 17.02
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2D
Current Rating (Amps): 5Average Probe Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64Resistance (mOhm): 35
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L36-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
PCI Standard Programmable Resistor Cards
Pickering's PCI Standard Programmable Resistor Cards include fully programmable resistor and potentiometer cards for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Cards can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection.
-
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
8-Channel, 100 MHz Counter/Timer/Frequency Meter Function Card
ProDAQ 3808
The ProDAQ 3808 function card, an enhanced version of the ProDAQ 3806 counter/timer function card, is designed to operate in one of three modes: pulse counter, frequency meter, or time interval counter. In the pulse counter and frequency measurement modes, users can process incoming signals of up to 25 MHz on each of the six channels. A time interval counter range is divided into six sub-ranges, covering times from 40 ns to 20000 s with a maximum resolution of 10 ns. For pulse-width measurements, the same ranges apply.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1H-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72H-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Innovative Open Standard
PROFINET
PROFINET is the innovative open standard for Industrial Ethernet, development by Siemens and the Profibus User Organization (PNO). With PROFINET, solutions can be implemented for factory and process automation, for safety applications, and for the entire range of drive technology right up to clock-synchronized motion control. PROFINET is standardized in IEC 61158 and IEC 61784. Profinet products are certified by the PNO user organization, guaranteeing worldwide compatibility.
-
product
Global Standard Model For 4 Point Probe Sheet Resistance Automatic Measurement System
RT-3000/RG-1000F
*Fully automatic system for large sizes of flat panel with glass loading robot*Tester self-test function, Measurement position correction function, wide measurement range*Min. 0.1 mm meas. resolution and user programmable test pattern*Host (CIM) communication and 2-D/3-D Mapping software
-
product
Standard Products
DLM’s standard product range is designed by experienced in-house design engineers and manufactured at our workshop in the UK by qualified technicians.
-
product
Erbium Fiber Frequency Comb
Detailed description of item: The AOSense frequency comb is a low noise, polarization maintaining (PM) device. Key features include a PM fiber architecture centered at 1550nm with turnkey modelocking; a free-running linewidth of the carrier-envelope offset frequency of <200 kHz; a temperature-insensitive all-fiber f-2f interferometer exhibiting fceo beatnotes with SNR > 45dB (300kHz RBW); and dual fast/slow cavity length actuators with a bandwidth of >300 kHz. The repetition rate of the comb is factory set and allows matching across multiple combs for dual comb applications. The optics package incorporates an optical heterodyne module designed for locking to the comb to an ITU-specified laser reference. The comb is capable of supporting an Allan deviation of < 5 x 10-18 at 1 second and ~10-20 after 105 seconds. Add-on features include all fiber extensions to visible wavelengths corresponding to several atomic transitions. An integrated comb electronics package is currently under development.
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3T
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High Frequency Multipin Coax Connectors
MDCX Series
Smiths Interconnect's multipin coax connectors MDCX offer low VSWR of 1.25:1 (typ) up to 10 GHz (max mated pair), maximum overall diameter of 0.125" fitted into low-profile micro-D housing, constant 50 Ohm airline impedance.
-
product
Frequency Meter up to 330 GHz
Frequency meter is intended for measuring frequency in range 70-330GHz.The Frequency Meter is based on sweepable heterodyne receiver. Fully outomated system allows to measure frequency without preslection frequency range.This solution is ideal for laboratory test measurement.
-
product
Millimeter-wave Operation With Frequency Extenders For M980xA PXI VNA
S95560B
banded vector network analyzer (VNA) using the M980xA PXI VNAs and N5252AW or N5262BW Frequency Extenders.
-
product
High Power Frequency Converter
BL+ Series
Behlman's BL-PLUS Series High Power AC Source/ Frequency Converter provide the performance of a linear with all the benefits of a switching amplifier. Instead of relying on large, noisy motor generators for AC power, today's testing facilities are switching to quiet, compact Behlman AC Power frequency converters.
-
product
DC Standard Source
SPS-31
Kongter Test & Measurement Co., Limited
SPS-31 is specially designed to test analog and digital DC/AC Voltage meter, Current meter energy meter, DC voltage transducer and Current transducer. It is widely applied for test, production and inspection in research institution, national measurement institution at all levels, and meter manufacturer.
-
product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30G
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
product
Frontend - Frequency Extension to D-Band (110 GHz to 175 GHz)
FE170ST
The R&S®FE170ST is ideal for early subterahertz and 6G research. By extending the frequency ranges for the R&S®SMW200A and R&S®SMM100A to the D band (110 GHz to 175 GHz) engineers can access the range they need and develop the next generation of mobile communications. The easy-to-use, fully-calibrated solution is compatible with our signal generator, analyzer and oscilloscope environments. Plug it in and start designing the next generation of mobile communications today.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B30
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Frequency Response Analyzer
A frequency response analyzer measures the gain and phase response characteristics with respect to frequency of the device or system under test, by applying a frequency swept sine wave to it and examining its response signal.Featured wide dynamic range realizes high precise measurement, and also ultra low frequency measurement.
-
product
High Voltage Standard
HVS
The HVS uses precision matched resistors for high accuracy; it is a modified Park divider structure.
-
product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72F-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard 1.00 (28.30) - 5.40 (153.00) Battery Probe
BIP-10
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00