Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
product
Switchable Fixed Frequency Synthesizer
EXP Series 2.25" x 2.25" x 0.6"
*Connectorized Package *Switches Between Multiple Fixed Frequencies *Exceptionally-Low Phase Noise *DRO Replacement *High Vibration Design
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25Z-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Digital frequency counters
The instrument is equipped, in addition to the 20 Hz-160 MHz input, a second input for measurement up to 2.4 GHz with an impedance of 50 Ohms.
-
product
Standard Type Spring Probes
From for bare board to for ICT, we have variety of spring probes for PCB. In addition to variety of tip type and total length, we also have receptacles that match the best to spring probes. We can also attach lead wire to the receptacles.
-
product
Electronic Ballast High Frequency Parameters Tester
UI2002A
• Measure Vrms, Irms, W, PF/Hz • Voltage range: 10~600V, Current range: 10~2000mA, Frequency range: 20~70kHz • Accuracy: Class 2
-
product
Standard Voltage 50 Pin D-Type Cables - Connector to Connector
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Standard for Mass Interconnect Performance
TITAN
TITAN sets the standard for Mass Interconnect performance, configuration modularity and long term reliability. TITAN has been designed to offer exceptional configuration flexibility for use with any ATE platform and offers unparalleled I/O density coupled with the widest selection of contact types available for Mass Interconnect.
-
product
Robotics and Machine Vision Standards
Accuracy in machine vision systems is critical to achieving strategic goals regarding quality, efficiency, and consistency. Use our ACCUplace product lines to calibrate vision systems’ distortion, placement/alignment, or other field parameters in systems used for guidance, identification, gauging, and inspection. Using our specialized ACCUedge® technology, our Robotic and Machine Vision Standards are manufactured with line-edge quality that is second to none in the industry, providing the precision needed to calibrate almost any system. Should you need to alter feature patterns, size, or substrate to fit your needs, fill out our Optical Components and Standards form to start the conversation.
-
product
Standard Air Capacitor Set, 1pF To 1000pF
16380A
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Cable Assembly, Receiver, High Frequency, 36", 10 SMA Plugs
540153010212
Cable Assembly, Receiver, High Frequency, 36", 10 SMA Plugs
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-3
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
PathWave BenchVue AC Source Avionics Standard Test Software
BV0028B
Control your AC source and accelerate pre-compliance testing as per the avionics and military-standard requirements at ease.
-
product
Full-Featured Open Source Free Implementation for the Object Management Group (OMG) Data Distribution Service for Real-Time Systems Standard
DDS Community
The DDS Community Edition is a full-featured open source, genuinely free implementation of the Object Management Group (OMG) Data Distribution Service for Real-Time Systems standard. Full-featured Apache license version 2.0 open source Data Distribution Service (DDS) implementation.
-
product
Single Frequency CW 532 NM Laser up to 18W
EQUINOX
Equinox is a single frequency, 532 nm continuous wave laser designed for a range of scientific applications including pumping any Ti:Sapphire laser systems. It is engineered to meet the needs of experimentalists requiring high-performance systems with an emphasis on reliability, stability and ease of use. The laser incorporates pump diodes within the central unit and is fully automated with hands-free operation and control via ethernet, webpage and TCP/IP remote interface. This completely sealed system is inherently stable with low noise levels <0.05 % RMS and ultra-stable output powers with ±0.5 % stability. Equinox has options of high output power up to 18 W. Other major applications include mixing source, pump source for dye lasers and frequency doublers, optical tweezers, and biomedical imaging.
-
product
Personal RF Detection Meters, High Frequency
Personal RF Detection Meters from Sensory Perspective Ltd
-
product
NanoLattice Pitch Standard (NLSM)
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HF-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4A
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard VXI Module Shield Kits With Address Switch Opening
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Clamshell design fits C-size modules with 96-pin connectors.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Address switch opening on component side shield.* Complimentary layout support includes PCB design template and CAD layout files.
-
product
GFS Primary Gravimetric Flow Standard
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
product
Frequency Synthesizers
A frequency synthesizer allows the designer to generate a variety of output frequencies as multiples of a single reference frequency. The main application is in generating local oscillator (LO) signals for the up- and down-conversion of RF signals.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25C-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Suitable For RTD Sensors Approved To ATEX And IECEx Standards
TTR200X -
The TTR200X is our mid range transmitter for RTD or Slidewire sensors approved to ATEX and IECEx standards. It can accept many different types of RTD sensor such as Pt100, 500, 1000 etc and slidewire sensors up to 100K Ohm
-
product
Standard Amplifiers
Teledyne RF & Microwave, a Business Unit of Teledyne Microwave Solutions (TMS), supplies catalog and custom RF and microwave amplifier designs for aerospace, defense, and industrial applications. These standard amplifiers, originally designed by Teledyne Cougar, provide both excellent stability and cascadability.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1B-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02





























