Teledyne LeCroy
Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively.
- (800) 553-2769
845 425-2000 - 845-578-5985
- contact.corp@lecroy.com
- 700 Chestnut Ridge Road
Chestnut Ridge, NY 10977-6499
United States of America
-
Product
4 GHz ProBus2 Differential Probe with Adjustable Tip
D400A-AT-PB2
Differential Probe
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
AC/DC Single Phase Digital Power Meter 100 kHz
T3PM1100
Power Meter
AC/DC Single Phase Digital Power Meter 100 kHz.
-
Product
LinkExpert Software
-
LinkExpert enables complete control and management of Teledyne LeCroy's family of Protocol Analyzer and Exerciser hardware. LinkExpert provides a convenient interface to run Compliance, Conformance and Validation tests on PCI Express (PCIe) and SAS (Serial Attached SCSI) links. The LinkExpert software interface is provided free of charge and includes as standard, several validation tests for PCIe Hosts (Root Complexes) and Devices (End Points).
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
8 GHz, 20 GS/s, 4ch, 100 Mpts/Ch High Definition Mixed Signal Oscilloscope
WavePro 804HD-MS
Oscilloscope
HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s.Up to 5 Gpts of acquisition memory enables detailed viewing of long events.15.6" 1900 x 1080 Full HD capacitive touchscreen.New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector.MAUI with OneTouch user interface for intuitive and efficient operation.Deep toolbox enables and simplifies complex analysis.Intuitive navigation to quickly find important features in long waveforms.Zone Trigger – Simple Triggering for Complex Signals.
-
Product
Open Compute Project ® Protocol Test Solutions
-
The global OCP community is a collaborative forum where vendors work together to improve how computing systems connect and interact. OCP equipment takes advantage of these improvements and open source designs to increase interoperability performance.
-
Product
10:1, 10 Mohm, 300 MHz Passive Probe
PP016
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
DL-ISO 1000 Vpp Square Pin Tip
DL-ISO-1000V-TIP
-
- Ideal for GaN and SiC devices- Highest system accuracy- Fastest rise time- High CMRR - 160 dB
-
Product
250 MHz 60 V Common Mode Differential Probe
DL02-HCM
Differential Probe
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
Product
T3DSO2000A Series Oscilloscopes
T3DSO2000A Series
Oscilloscope
Teledyne Test Tools T3DSO2000A Oscilloscopes feature two channel and four channel models with analog bandwidth options from 100 MHz to 500 MHz. Each model offers a maximum sample rate of 2 GSa/s, and a maximum memory depth of 200 Mpts in half channel mode. All models incorporate two 2 GSa/s ADCs and two 200 Mpts memory modules. When all channels are enabled, each channel has sample rate of 1 GSa/s and a standard record length of 100 Mpts. When only a single channel per ADC is active, the maximum sample rate is 2 GSa/s and the maximum record length is 200 Mpts. For ease-of-use, the most commonly used functions can be accessed with its user-friendly front panel design.









































































