Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States of America
Categories
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Particulate Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API offers a combination of particulate matter measurements to meet a variety of data quality objectives for regulatory ambient air quality monitoring. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support.
-
product
CAPS Trace-Level NO2 Analyzer
Model T500U
Teledyne Advanced Pollution Instrumentation
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.
-
product
Portable Zero Air System
Model 751H
Teledyne Advanced Pollution Instrumentation
The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes.
-
product
UV Fluorescence SO2 Analyzer
Model N100
Teledyne Advanced Pollution Instrumentation
The Model N100 instrument uses the proven UV-fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Sulfur Dioxide (SO2) gas.
-
product
Sulfur Compound Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API's Sulfur compound analyzers utilize familiar UV Fluorescence technology to produce reliable and accurate gas measurements. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
product
Dissolved Ozone Instruments
Teledyne Advanced Pollution Instrumentation
For measuring dissolved ozone concentrations in water a microprocessor controlled instrument can be used for automatic and continuous measurement by means of an disinfectant sensor. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
product
Portable Trace-Level O3 Calibrator
Model T753U
Teledyne Advanced Pollution Instrumentation
The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.
-
product
THC-CH4-NMHC Analyzer
Model N901
Teledyne Advanced Pollution Instrumentation
The Model N901 is a near-continuous hydrocarbon gas analyzer that measures the concentration of Methane (CH4) and Total Hydrocarbons (THC) in air. The concentration of the non-Methane (NMHC) component is calculated by the subtraction of CH4 from THC, with high sensitivity and accuracy. The hydrocarbons are measured using a Flame Ionization Detector (FID), in combination with gas chromatography (GC). The instruments range and performance are tuned specifically for use in ambient air quality monitoring assessments.
-
product
Process Ozone Monitor
Model 465M
Teledyne Advanced Pollution Instrumentation
The Model 465M is a microprocessor based medium range ozone monitor for measuring process ozone concentrations in water treatment, food processing, and research applications. The design has been specifically optimized for applications requiring the measurement of ozone at near-ambient pressure such as water treatment contactor off-gas measurement. The Model 465M has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465M is available in a NEMA 4X wall mount enclosure.
-
product
Mid-Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200M
Teledyne Advanced Pollution Instrumentation
The Model N200M uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
Gas Filter Correlation CO2 Analyzer
Model N360
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Chemiluminescence NOX-NO2-NO Analyzer
Model N200
Teledyne Advanced Pollution Instrumentation
The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.
-
product
Gas Measuring Instruments
N Series
Teledyne Advanced Pollution Instrumentation
N Series Gas Measuring Units for SO2 (Sulfur Dioxide), NO, NO2, NOX (Nitrogen Oxide, Nitrogen Dioxide), CO (Carbon Monoxide), CO2 (Carbon Dioxide), O3 (Ozone), True, Direct NO2, NOX, NO, CH4 (Methane), THC (Total Hydrocarbons), and more
-
product
PM Mass Monitor
Model T640
Teledyne Advanced Pollution Instrumentation
The Model T640 PM Mass Monitor is the next breakthrough in ambient particulate monitors. The T640 delivers 1-min or better time resolution with exceptional sensitivity and precision. The instrument is very low maintenance and requires no sample media for minimal cost of operation.





































































