Filter Results By:
Products
Applications
Manufacturers
-
product
PXI Strain Gauge Simulator Module 6-Channel, 2k
40-265-306
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 2kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
product
PXI Strain Gauge Simulator Module 4-Channel, 3k
40-265-104
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 4-channel, 3kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
product
Digital Strain Gauge Sensor
ZET 7110
The ZET 7110 module is intended for measuring the relative deformation using primary transducers based on tension gauges. These may be either assembled tension gauges (force gauges, torque gauges), or detachable tension gauges connected using half-bridge or bridge mode.
-
product
PCI Strain Gauge Simulator Card, 4-Channel, 1k
50-265-204
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
product
Reusable ICP® Strain Gauge
This high-resolution dynamic alternative to bond foil strain gauges uses a quartz sensing element in a durable, titanium housing. It has 0.0006 microstrain resolution, 5 volt output, 100k Hz frequency response and 0.5 gram mass for lightweight test articles. The reusable sensor comes with a calibration certificate, attaches to the test specimen in 60 seconds and is removed in 10 seconds.
-
product
20-Pin GMCT Cable, Male to Unterminated, Tinned Ends, 10A, 0.5m
A020GMR-T-0C050
The 20-Pin GMCT cable assembly is constructed from 19/0.254 (18AWG) Tinned Copper Wire with PFA insulation. Screwlocks are provided to secure the connector to associated product. The unterminated connections are coded to match the connector pin designation. Users may need to make their own cable strain relief arrangements when using this product and should ensure appropriate electrical safety precautions are observed.
-
product
Signal Conditioning System
28000
The Precision 28000 Signal Conditioning System makes it easy to manage a test with up to 256 channels of fully programmable transducer conditioning. Choose a mix of bridge, charge, IEPE w/TEDS, voltage (filter amplifier), strain, thermocouple, RTD/potentiometer, frequency, or other transducers. Self-tests traceable to NIST. 4, 8 and 16-slot rugged and transportable mainframes feature integrated cooling. Customize the 28000 for high-speed transient applications, static applications, or a combination of both.
-
product
Bending Deflectometers For ISO 178, JIS K 7171, And ASTM D790 Compliant Testing
After tensile testing, flexural tests are the most common strength tests for plastics and other resins. The main standards for plastic flexural (bend) tests are ISO 178, JIS K 7171, and ASTM D790, which require very accurate test systems. These standards include flexural strain measurements using a deflectometer, ranging from micro-strain measurements in the elastic region, the reversible elongation at the beginning of tests, to larger strain measurements in the plastic region. Shimadzu's deflectometers integrate easily into AG-X plus series, AGS-X series, and EZ-X test frames and Trapezium X testing software. Since these deflectometers push up against the specimen from below, the specimen color is not a limiting factor, as can be for laser type non-contact deflectometers. Furthermore, these deflectometers can partially absorb the shock during specimen failure, preventing specimen fragments from scattering.
-
product
CAN Sensoy/ Interface
Strain
Reach Technologies' CAN Strain Sensor Interface sources, conditions and digitizes 8 strain sensor inputs for collection via CAN. The module is ideal for conveniently adding strain data to a distributed CAN network. The CAN Strain Sensor Interface is configurable via a CANopen stack.
-
product
MINITAURs - 8-channel universal DAQ system
MINITAUR-S
Mixed signal 8-channel data acquisition system and multichannel data logger with cutting-edge technology at an attractive price. Universal analog inputs can accommodate various signals like strain gage, IEPE, voltage, current, RTD, thermocouple, and LVDT.
-
product
Press Force Load Cell
6000 Series
Press Force Load Cells are strain gage based transducers for press-force monitoring. This type offers capacities up to 100 kN with compensated temperature performances. Cable is contained within a stainless steel spring for strain relief purposes for additional protection.
-
product
Strain Sensors
Conventional strain sensors are based on strain gage technology. In order to effectively measure the strain values in a force or load measurement application, a full, 4 element strain gage bridge circuit is utilized. The configuration is known as a Wheatstone Bridge Circuit. A Wheatstone Bridge has a very linear output in it’s midrange. That being considered +100% to -100% of range. Unfortunately, a Wheatstone Bridge becomes non-linear above the upper and lower extremes of range. Therefore, significant errors can result above the end points when attempting to take precision measurements. It is particularly important to take accurate measurements in some R&D or control applications. To avoid the mentioned error issues, PCB manufactures quartz piezoelectric strain sensors that output the same mV/microstrain sensitivity throughout the entire useful range. Thus, accuracy is improved and control requirements are enhanced that may occur at positive extremes of the measurement range. The models RHM240 and model 740B02 series sensors are the strain sensors for these applications.
-
product
Strain Measurement Trainer Module
Unitech Scales And Measurements Pvt. Ltd
Strain Measurement Module comprises of Cantilever Beam bonded with four strain gauges,pan and weights upto 1Kg. Digital 3½ digit indicator module is supplied to read the microstrain.
-
product
Video Extensometers
AMETEK Sensors, Test & Calibration
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
product
Strainer-Recorder
To ensure reliable operation of the measuring complex in the harsh conditions of ice tests, it is based on the industrial measuring platform NI CompactRIO, which provides mechanical strength and operation at negative temperatures.The system provides for operation both under the guidance of an operator with displaying the voltages removed from the ship's hull in the form of graphs on a computer screen connected to the strain gauge station via an Ethernet line, and in stand-alone mode, when the recording of a given duration is initiated by the station on pre-configured events: amplitude exceeding by one of channels, an external discrete signal or periodically at specified intervals.
-
product
26-Pin D-Type Connector Female
92-960-026-F
This accessory is designed to allow users to directly terminate a cable with soldered connections to the connector. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical precautions are observed.
-
product
Detrenching Grapnel
The Detrenching Grapnel is manufactured from high tensile steel, suitable for withstanding the harsh offshore environments. The structure and material of the grapnel is tested using finite element analysis which is performed during the design phase. This simulates the various stresses and strains acting on the grapnel in a variety of differentseabed conditions and allowed for optimisation of the design.
-
product
Enclosure, S6, 2U Height, 4 Cable Clamps, 12" Depth
410112712
Enclosure, S6, 2U Height, 4 Cable Clamps, 12" Depth Includes hinged cover and 4 cable clamps for discrete wiring that provide secure strain relief. With the cable clamps open- stiffener bar can be removed allowing installation or removal of cables without unplugging patchcords from the assembly. Housing: Material = .06" Aluminum, Finish = Powder Coat BlackCover(s)/Access Panel(s): Material = .12" Aluminum, Finish = Black Anodize
-
product
Scope Probes
3900 Series
Now Probe Master offers a rugged, heavy duty oscilloscope probe at low prices. This probe features a snap-on rotating ground lead, and a heavy duty fixed tip. The switchable model allows for quick finger tip change between 1X, 10X and reference ground. The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality at a low cost. Accessories include Sprung Hook, 6" Ground Lead and Trimmer Tool.
-
product
Strain Gauge Measuring Instruments
It is a Strain Gage Indicator and also function as a Strain Gage Transducer Indicator.As a Strain Gage Indicator, it can support 10 types of bridges and dummies. While if used as a Strain Gage Transducer Indicator, there are 24 bits A/D converts to make the measurement.
-
product
Custom Bolt-On Strain Sensors
Our custom bolt-on strain gauge sensors are designed and manufactured to your application, based on your drawings and specifications, including all types of output formats. Ideal for dynamic load monitoring, capable of measuring and monitoring axle stress and weight with high accuracy.Do you have an application for strain gauge measurement that requires a quick and simple installation, repeatedly, in multiple locations? Perhaps you need a sensor with high environmental protection, which removes the necessity for time-consuming cleaning, complicated soldering and messy strain gauge adhesives?
-
product
Receiver, I2 Micro ICon, 168 Position, For Crimp Contacts
310130102
The i2 Micro iCon receiver is a one piece connector capable of holding up to 168 QuadraPaddle contacts. QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. This i2 receiver is made for crimp contacts. Accessories such as keying pin kits, protective covers, and strain relief are available.
-
product
Contactless Video Extensometers
Jinan Testing Equipment IE Corporation
Deformation measurement of samples during material testing with use of the Video extensometer MercuryRT allows applying multiple virtual probes (Movement Sensors)on markers and advanced image featuresto be tracked, including the natural pattern of the sample surfaces.The common resolution of standard system is within 500 nm and 5 m. The system fulfils class 0.5 or B-1 of classification according to ISO 9513 and ASTM E83. In certain camera use case, the system resolution reaches the level of 100 nm - 500 nm and system fulfils the class 0.2. The strain resolution can reach 10 microstrains. Material testing,Component testing ,FEA validation,Vibrography .
-
product
Rectal Probe For Rats (Isolated)
RET-2 ISO
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - '' long, .059'' diameter. Tip diameter .125'', 5 foot lead length. Time constant 0.8 seconds.
-
product
Test Equipment
Southern Photonics designed and manufactured all the test equipment currently being manufactured by Coherent Solutions, as well as equipment for non-telecoms applications. This includes FBG strain interrogators, optical pulse phase analysers, OSNR meters, optical power meters, optical spectrum analysers, optical gas sensors… you get the idea. All test equipment we build is robust and easy to use. The picture shows some of what we can do – anything from prototype benchtop test gear (as in the combination ASE source and laser combiner on top of the stack) to field test equipment (the portable fast OSA on the bottom).
-
product
Junction Boxes
VPG Transducers created one of the largest load cell and transducer manufacturers in the world when we brought decades of weighing and force measurement experience under one roof. By harnessing the power of our collective expertise and experience in advanced strain gage technology, we are able to continuously challenge the status quo. As trusted partners, we are committed to providing world-class solutions that meet your needs.
-
product
15-Pin D-Type Connector, Female
92-960-015-F
This accessory is designed to allow users to directly terminate a cable with soldered connections to the connector. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical precautions are observed.
-
product
Draw Tower Grating
(DTG)
The Draw Tower Grating Chain consists of high strength coated FBGs which are positioned in a serial configuration. Thanks to the special production process, writing the Fibre Bragg Gratings during the drawing of the Fibre, the array can be made without any splices. Furthermore the FBGs can be mounted directly on a structure without coating removal for sensing applications. The different sensing points make use of the inherent temperature and strain sensitivity of the fiber to measure temperature or strain respectively.
-
product
8 Pin Power D-Type Male Connector, 40A, Without Backshell
92-960-008-M
This connector is designed to allow users to directly terminate a cable with soldered connections. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical precautions are observed.