Filter Results By:
Products
Applications
Manufacturers
-
product
3U OpenVPX High Density Multifunction I/O Board
68CB6
The 68CB6 is a Configurable Open Systems Architecture™ (COSA®) 3U OpenVPX™ board that is preconfigured with 10 different “inboard” I/O, measurement and communication functions. This Combination-function Board (CB) provides a full suite of some of the most common & useful function interfaces supporting many different applications. The 68CB6 features a wide but dedicated selection of functions: Standard Functionality Discrete I/O (DT1); Successive Approximation Register (SAR) ±100 V Analog-to-Digital (AD); Isolated High Voltage Analog-to-Digital (ADF); ±10 V Digital-to-Analog (DA); Thermocouple (TC1) or Resistance Temperature Detector (RT1); Full-bridge Strain Gauge (SG1); Transmission/gear box Chip Detection and Fuzz Burn (CD1); LVDT-to-Digital linear (LD6) displacement (position) measurement, AC Reference Source output (AC2); CAN bus communication (CB8). The 68CB6 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for external intermediate circuit considerations such as pull-up resistors or mechanical configuration jumpers. Inboard functions are software controlled and memory addressed, accessed in similar COSA® modular fashion to maintain seamless common NAI Software Support Kit & API/library structures.
-
product
4-Channel 200 MHz A/D with DDC, Virtex-7 FPGA - 3U VPX
Model 52761
- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Four 200 MHz 16-bit A/Ds- Four multiband DDCs- Multiboard programmable beamformer- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x4- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
product
Xytronic Three-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-30, RX-31 and RX-33
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
product
Automated System for Identification and Control of Pharmaceutical Codes
The automated system for identifying pharmaceutical codes includes two scanners of the pharmaceutical code, two sensors for the presence of an object and a data processing unit (BOD). When the box or instructions are passed under the object presence sensors, the farm code is read by the corresponding scanner and the results are transmitted to the computer via the Ethernet interface. The BOD verifies the correctness of the read out farm code by comparing this code with the reference farm code set at the beginning of the system operation. If the farm code has not been read or does not match the standard, the packaging machine stops and the type of error is displayed on the indicators.
-
product
HBM Verification Tester
HBM-VT
High Power Pulse Instruments GmbH
- HBM pulse generator verification tester according ANSI/ESDA/JEDEC JS-001 up to ±10kV- To be used in HBM test and qualification labs for regular pulse generator specification compliance test in order to fulfill lab audit and certification requirements- Fully automatic compliance test and verification of HBM pulse generators regarding ANSI/ESDA/JEDEC JS-001 normative standard at 3 different load conditions: Short Circuit, 500 Ω, and a reference diode at VBR=15 V reverse breakdown voltage, including DC test- Parameter evaluation and verification of the transient HBM current waveforms: Peak Current, Rise Time, Decay Time, Maximum Ringing Current- Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, 8010C, HBM-TS10-A hardware systems in combination with HBM-S1-B (6kV) pulse generators (upgrade on request)- Fully automatic test report generation (PDF)- Electrically floating (no fixed system ground): The HBM loads, current sensor output, USB control interface and the enclosure are electrically floating. There is no limiting system ground which may introduce common-mode interference induced HBM current measurement errors.- Isolated industrial full-speed USB control interface- Isolated power supply derived from USB port- Compact size 126mm x 82.5mm x 44.5mm
-
product
0.25° Accuracy Roll & Pitch Dynamic Motion Sensor
DMS-RP25
The DMS range of motion sensors is designed specifically for the motion measurement needs of the marine industry. Whether it is achieving IHO standard survey from any size of vessel, or providing safety critical monitoring of offshore platforms, large vessels, helicopter landing decks, cranes and positioning systems, the DMS provides accurate motion measurement in all sea conditions. Incorporating an enhanced external velocity and heading aiding algorithm for improved accuracy during dynamic manoeuvres, the solid state angular rate sensors offer reliability in the highest performing vertical reference units ever produced by TSS.
-
product
4-channel ADC Module
FMC140
Sundance Multiprocessor Technology Ltd.
The FMC140 is an analog-to-digital (A/D) FMC daughter card that provides four 16-bit A/D channels at 370MSPS which can be clocked by an internal clock source (optionally locked to an external reference) or by an externally-supplied sample clock. A trigger input is also available for customized sampling control. The FMC140 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1-2010). It offers front panel analog I/O access and can be used in a conduction-cooled environment.
-
product
1 GHz A/D and D/A with Virtex-6 FPGA - 3U VPX
Model 52630
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Supports gigabit serial fabrics including PCI Express, Serial RapidIO and Xilinx Aurora- One GHz 12-bit A/D- One GHz 16-bit D/A- Up to 2 GB of DDR3 SDRAM or 32 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factors provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount
-
product
4-Channel 200 MHz A/D with DDC, VITA 49.0, Virtex-6 FPGA - 3U VPX
Model 52664
- Complete radar and software radio interface solution- PCIe output supports VITA 49.0 VITA Radio Transport (VRT) Standard- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 200 MHz 16-bit A/Ds- Four multiband DDCs (digital downconverters)- Multiboard programmable beamformer- Up to 2 GB of DDR3 SDRAM or 32 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factors provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
product
FPGA Mezzanine Card
FMC116
The FMC116 is a 16-channel ADC FMC daughter card which is fully compliant with the VITA 57.1-2008 standard. The FMC116 provides 16 A/D 14-bit 125Msps channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available.
-
product
Electronic Stethoscopes
Electronic Stethoscope Standard Headphones are designed to help locate the source of excess bearing and machine noise easily at low cost, it is an ideal easy to use listening device for mechanically generated noise in all types of applications, the 3.5mm jack socket tape output can also be fed into an audio tape recorder to store the data for either further analysis or as a reference for future comparison.
-
product
Balance Thermocouple Power Sensor, DC To 18 GHz
N8481S
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
product
4-Channel 200 MHz A/D with DDC, Kintex UltraScale FPGA - 3U VPX
Model 52861
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Complete radar and software radio interface solution- Supports Xilinx Kintex UltraScale FPGAs- Four 200 MHz 16-bit A/Ds- Four multiband DDCs (digital downconverters)- 5 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x4- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
product
Coating thickness XRF Standards
We manufacture high accuracy reference standards capable of calibrating virtually any X-Ray Fluorescence (XRF) coating thickness and composition analysis system.
-
product
4-Channel DAC FMC Module
FMC204 – HPC
Sundance Multiprocessor Technology Ltd.
The FMC204 is a quad channel DAC FMC. The FMC204 provides four channels of 16-bit D/A @ 1 GSPS enabling simultaneous sampling at a maximum rate of 1 GSPS. The sample clock can be supplied externally through a coax connection or supplied by an internal clock source (optionally locked to an external reference). Additionally a trigger input for customized sampling control is available. The FMC204 daughter card is mechanically and electrically compliant to FMC standard (ANSI/VITA 57.1).
-
product
Package Testing
Lansmont package testing equipment is designed to perform industry standards, such as ASTM, ISTA, ISO, EUMOS and others. Our equipment is compliant with all of the most common ASTM and ISTA package testing procedures. There are individual standards that specifically reference how to perform drop testing, compression testing, side impact testing and vibration testing. In addition to those standards, there are groups of procedures referred to as distribution simulation tests, which incorporate some strategic combination of testing inputs, with the idea of simulating a typical journey through the supply chain. Some of the most common distribution simulation standards that are performed globally are published by ASTM and ISTA.
-
product
Range-Doppler Target Generators
ATG9100
The ATG-9100 is an example of a laboratory-quality instrument that will simulate complex target motion. Microwave signals from the speed camera enter the instrument through an integrated antenna which is then downconverted and digitized. Target simulation data is added to the digitized signal to provide range and Doppler information. The modified digital data is then converted back to an IF and upconverted to the original microwave frequency of the speed camera and radiated back through the antenna. Since the ATG-9100 can be phase-locked to an external 10 MHz reference standard, this instrument is suitable for use as a calibration standard for speed cameras.
-
product
4-Channel ADC FMC Module
FMC103 – LPC
Sundance Multiprocessor Technology Ltd.
The FMC103 is a four-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC103 card provides four 12-bit 210 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC103 has the LPC (Low-Pin Count) 160-Pin connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.
-
product
Shielding Effectiveness/ Conductivity Test
EM-2107A | 30 MHz – 1.5 GHz
The EM-2107A is a standard test fixture for evaluation of the electromagnetic shielding effectiveness of planar material. The fixture is an enlarged section of coaxial transmission line and complies fully with the requirements of ASTM test method D4935-1. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred. The EM-2107A is provided with a reference standard test specimen, a dynamic range specimen. Dynamic range of greater than 80dB is achievable, although the cables and other test system components usually establishes the limiting factors.
-
product
E-Band Signal Analysis Reference Solution
The E-band signal analysis reference solution provides an effective measurement solution for today’s wideband signals as well as emerging communications standards. With the M1971E waveguide harmonic mixer, which provides a 55 to 90 GHz input; Keysight oscilloscopes, which provide excellent signal integrity; and the powerful 89600 VSA software, you have a high-quality wideband measurement solution. A simple user interface also provides integrated mixer setup, correction and LO optimization, allowing for accurate measurements.
-
product
Class 2 Sound Level Meter
SP79
The SP79 is a Class 2 sound level meter for on-site measurements in accordance with Noise at Work legislation in industrial and office environments. Featuring A and C frequency weighting and fast and slow time weighting, the compact design can be handheld, or mounted on a tripod for longer term monitoring of Min / Max values. Detailed recording and analysis can be made using the AC and DC outputs. The SP79 complies with BS EN 61672-1:2003 and is supplied with a detachable windshield and hard carry case. The large high contrast display includes both digital reading and analogue bar graph. An optional Class 2 sound level calibrator is available to verify accuracy before and after readings in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB.
-
product
Fully Automatic Colorimeter
DRK103C
Shandong Drick Instruments Co., Ltd.
(1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.
-
product
Light Meters & Sensors
The light meters and sensors product line at Gamma Scientific is extensive. Find sensors, light meters, photometers, radiometers, reference standard detector systems, and transimpedance amplifiers that meet your testing requirements.
-
product
Heading Reference Directional Gyroscopes
4000HR-series
The 4000HR air-driven directional gyro offers some of the best features of our other popular models. It inherited all of the functionality and reliability of the industry standard 4000B upon which it’s based, and it picked up a heading reference bug from the 4000C autopilot model.
-
product
Three Phase Reference Standard Meter
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
product
8-Channel ADC Module
FMC107
Sundance Multiprocessor Technology Ltd.
The FMC107 is an eight-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC107 card provides eight 12-bit 65 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC107 has the LPC (Low-Pin Count) 160-Pin connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.
-
product
Ultra Low Noise, Rubidium Frequency Standard.
A10-M
Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.
-
product
8 CANBus Channels, CAN 2.0 A/B Protocol
CB1
The serial bus system with real-time capabilities is the subject of the ISO 11898 International Standard and covers the lowest two layers of the ISO/OSI Reference Model. Our CANBus modules provide independent, isolated channels of CAN serial data bus links, conforming to the ISO 11898 International Standard. All CAN nodes are able to transmit data and several CAN nodes can request the bus simultaneously.
-
product
RF One Power Meter
The RF One Power Meter is a very versatile instrument covering both analog and digital carriers in an extremely wide frequency range from 30MHz to 6GHz. The RF One is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The RF One instrument is small, handy and light weight battery operated with more than 3 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.
-
product
Portable Meter Test Kit
UTEC 430
The UTEC 430 is the first Portable Meter Test Kit to support both the Radian Dytronic (RD) and the installed base of Radian Metronic (RM) reference standards. The ability to support both reference standards makes the 430 the ideal budgetary solution for traditional on-site meter testing using Phantom Load current sourcing. Do not let its compactness fool you, the UTEC 430 has three 30 Amp current output elements for performing single-phase or three-phase meter testing. When each element is combined using the optional open link cable harness, the UTEC 430 can source up to 90 Amps.