Filter Results By:
Products
Applications
Manufacturers
Power Factor
measures true power over apparent power.
-
product
Portable Power Factor Meter
ST-2000 Cos∮
Standard Electric Works Co., Ltd
● Principle : Phase angle sensing transducer● Rated Accuracy : ±3% phase angle● Scale : Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 Lag Power Angle: Lead 90° – 0° – 90° Lag● Effective Power Factor Measuring Range : Lead 0.5 – 1.0 – 0.5 Lag● Scale Length : Approx. 135mm(5-3/8”)● Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
-
product
Amp, Power Factor & VAR Recorder
Varcorder
The Varcorder measures and records Amps and Power Factor. A voltage constant is then applied in software to calculate VARs. The Varcorder uses the same current sensor technology as the original Ampstik. This patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed, and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The true power factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard shotgun style hotstick. Once on the line, it immediately begins to collect and record the current and power factor on the line.
-
product
Intelligent Power Factor Regulator
Model -KM PFR 9-6 / 9-12
Kusam Electrical Industries Limited
The pioneers & leaders in high quality power factor controllers & maximum demand controllers, now introduce 2 new economy models of power factor controllers. These controllers have microprocessors for automatic control of power factor. It has digital indication for power factor.
-
product
GDGS Transformer Power Factor And Tan Delta Tester
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester
-
product
Portable Wattneter (Low Power Factor 0.2)
Supreme Instrument Laboratories
Range : 0-0.5/1 Amps, 0-50/100/200 Volts.0-0.5/1 Amps, 0-75/150/300 Volts0-0.5/1 Amps, 0-150/300/600 Volts0-0.5/1 Amps, 0-125/250/500 Volts
-
product
Artificial Phantom Load with Power Factor
RC-50
The RC-50 Artificial Phantom Load has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges. Features: Artificial Load, Light Weight, 50 Amps, 50% Power Factor.
-
product
Power Factor Controller
Rishabh Instruments Pvt. Ltd.,
Is an intelligent power factor controller for reactive power compensation. It has 4 / 6 / 8 control outputs with LED Display for target PF.
-
product
Automatic Power Factor Controller
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
product
Power Factor RLC Load
3282(280V,1875W / 3700VA )
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
product
Power Factor Transducer
*(0.2%ACC.) : TDPF. *(0.5%ACC.) : TSPF
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C± 5 °C• High Dielectric Strength 2.6KV AC / Min, Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
product
Phase Angle and Power Factor Transducer of Single-phase AC Electric Power
NMTFi
The NMTFi device is a phase angle and power factor transducer operated in single-phase power network and featuring two independent analogous outputs. The A output measures the phase angle between voltage and current, the B output measures the power factor. In such a was one single NMFTi transducer is able to replace two customary transducers thus making it possible to achieve significant savings in installation space.
-
product
True RMS 1000V Wireless Multimeter w/ Power Factor
DM525
UEi Test & Measurement Instruments
The DM525 is a Industrial level multimeter with Wireless capability and a free App. It also has Watt/Power Factor lessening the chance of incorrect readings from ghost voltages. The increased functionality gives technicians the ability to do more.
-
product
Universal Power Conditioner
SP1250LE
The SP 1250LE Universal Power Conditioner is a Power Factor Corrected 875 W/1250 VA device designed to enhance utility power or repair failing utility power in traffic, IT or security cabinets. Clary's SP 1250LE can also operate as an On-Line, Dual Conversion UPS when configured with the optional battery pack, which extends the reliability of the cabinet when the utility power fails (black out) or falters (brownout).
-
product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations
-
product
GO-2000 Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
GO-2000 is a highly automated luminaire light distribution performance test system, mainly used for all kinds of indoor lamps, road lamps and floodlights ( add B-β test accessories) light distribution performance test, total luminous flux test and electrical parameters (voltage, current, power, power factor) measurement.
-
product
Transformer Testers
*Quickly tests deenergized power distribution transformers*Briefly energizes the transformer and takes a snapshot of the condition by measuring the voltage, current and power factor of the test signal*Tests overhead, pad-mount and distribution transformers*Audible alarm confirms successful test*Improve SAIDI statistics by quickly testing and getting the transformer back in service*Auto self-test performed with every test*Compact, lightweight and easy-to-use
-
product
Three Phase Portable Energy Meter Test Instrument Type KP-P3003-C
Bofa Instrument & Equipment Co., Ltd
Three-phase portable energy meter test instrument type KP-P3003-C with current and voltage source is an ideal device to test all kind three-phase energy meters accuracy below 0.2. The equipment can generate 3-phase voltage, 3-phase current and any power factor signal, the standard meter inside the equipment is class 0.05. The equipment is box structure, light, and easy to carry, it is very convenience to test meters on site, moreover the equipment can be used for testing meter in meter manufacture and as testing equipment in R&D institute.
-
product
PFC Controllers
Renesas' power factor correction (PFC) controller family uses boost topology and are suitable for AC/DC power systems, up to 2kW and over the universal line input. These PFC controller IC's operate in continuous conduction mode (CCM), and the small external components result in a low cost design without sacrificing performance.
-
product
600W to 1000W - Single Output
HWS-L/BAT Series
*Low profile*Active Power Factor Correction*Universal input (85 - 265VAC)*Low acoustical noise*Adjustable current limit*Constant current style limit*Medical Certifications (HWS1000L)
-
product
Power Quality
Schweitzer Engineering Laboratories, Inc.
SEL power quality controls increase power efficiency and reliability by improving a system’s power factor and voltage stability.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
AC Power Source
61600 Series
Built-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable voltage,current limitComprehensive measurement capability,V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlOne-key recall for 9 different voltage and frequencyProgrammable slew rate setting for changing voltage and frequencyAnalog input for power amplifierOptional Analog programming interfaceOptional GPIB and RS-232 interface(Model 61601~61605)Full protection: OP,OC,OV and OT protectionEasy use graphic user interface: softpanel (option)Capable of delivering power output up tp 90KVA by implementing Master-Slave operation
-
product
Analog Panel Meter
Hoyt Electrical Instrument Works Inc.
Hoyt supplies a complete line of panel meters for several vertical markets (Switchboard, Audio, Power, Marine, and Power Generation). The meter movements can be pivot & jewel or taut band. So whether you are looking for AC/DC amps, volts, frequency, elapsed time, watts, vars, power factor, or any other measurement parameter we have the meter.
-
product
Automatic Battery
BATLV1600
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations. These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cablesof adequate cross section, and to supply the operation signal from suitable current transformer. FML capacitors and swichgear inside metal cabinet. Floor mounting.
-
product
Programmable AC Electronic Load
63800
Chroma Systems Solutions, Inc.
The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing resulting in reliable and unbiased test results.
-
product
Programmable AC Power Source
LSP-500VAC
• Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);
-
product
Plug-In Power Supplies
VECTOR Electronics and Technology, Inc.
Standard PCI output Voltages : 5.0V, 3.3V, +12.0V, -12.0VHot swap, N+1 redundancy with internal OR-ing diodes.99 power factor corrected AC 90-264V input DC 36-72V (48V nom.), or DC 18-32V (24V nom.) Current sharing on 5.0V and 3.3V outputs Power & Fault LED indicators to faceplate Excellent performance
-
product
Electronic Ballast Tester
WT4000
• Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.