Filter Results By:
Products
Applications
Manufacturers
-
product
Tailored for Measuring Emissions
CEMS solutions
SICK's CEMS solutions are analyzer solutions that have been specifically designed for measuring emissions at power plants, industrial facilities, or on ships. CEMS solutions can be used to measure pollutants and reference quantities and to perform data processing on the results in accordance with the relevant national or international legislation.
-
product
Smart Environmental Database
The Smart Environmental Database supports the creation of MRM methods for environmental pollutants.
-
product
New Resistivity Inversion Software
EarthImager 3D
AGI is proud to introduce the new EarthImager 3D resistivity and IP inversion software. This software inverts resistivity and IP data acquired with electrodes arranged in boreholes and/or on the surface and presents a 3D volume of inverted resistivity data with advanced volume rendering technique. The final resistivity or IP image-volume can be rotated in any orientation, zoomed in and out, and translated to anywhere inside the image window in order to see the volume of interest in detail. Colors representing areas of less interest can be made transparent so that the shape of a pollution plume, for example, can be visible. With EarthImager, 3D resistivity inversion can be as easy as two steps: Read Data and Start Inversion with only a few mouse clicks.
-
product
Archival Storage Rooms
Darwin Chambers Company’s NFPA, GSA, and NARA Directive 1571-compliant Archival Storage Chambers are engineered to provide maximum value, efficiency and conformance with all applicable standards and codes. Archival chambers provide environmental controls for storing records and materials (including paper documents and items with high fibrous content, various films, microfiche, and photographic materials) that require permanent protection for storage and preservation. Our high-performance systems are offered with nearly unlimited operational fail safes, includ- ing full system and control redundancy. In addition to keyed entry, numerous security options are also available, due to the often irreplaceable nature of the materials to be stored and preserved in this type of chamber. Our chambers are engineered to accommodate the loads and unique requirements of the specific materials to be stored, with industry-leading control and uniformity of both temperature and humidity variables. Design considerations include both functional and operational efficiencies and reliability, the safety and comfort of operating personnel, and the ongoing protection of the archived materials from fire, water, light degradation, pests, mold and natural contaminants, pollutants and other man- made threats.
-
product
Water Quality Monitoring System
WQMS
Water Quality Monitoring System (WQMS) is a facility to measure pollutants such as Chemical Oxygen Demand (COD), Total Phosphates (TP), Total Nitrogen (TN) etc. The required parameters are customized according to the type of factory and discharge regulations.
-
product
Ambient Measurement
A measurement of the concentration of a substance or pollutant within the immediate environs of an organism; taken to relate it to the amount of possible exposure.
-
product
GFID Analyzer
Gasmet Flame Ionization Detector (GFID) is designed for continuous total hydrocarbon (THC) measurements. GFID analyzer offers a TÜV certified solution (QAL1) for measuring pollutants from hot, wet and corrosive gas streams.
-
product
Cylinder Type Transformer Systems
YDTW\YDTCW Series
Shanghai Jiuzhi Electric Co., Ltd.
Conventional AC test transformers are especially designed for testing objects of medium capacitance. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).The possibility of stacking several of these transformer modules allows reaching very high voltage levels by keeping reasonable floor space.
-
product
CAPS Trace-Level NO2 Analyzer
Model T500U
Teledyne Advanced Pollution Instrumentation
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.
-
product
Sound Level Meters
Shenzhen Graigar Technology Co.,Ltd.
A sound level meter is an instrument that can measure sound level, commonly used in noise pollution studies for the quantification of different kinds of noise, especially for industrial, environmental and aircraft noise.
-
product
Noise Control And Acoustical Consulting Services
Our acoustical consultants use the latest and most advanced noise prediction and modeling software, precision sound measurement equipment and detailed acoustical analysis that enable us to help our clients achieve their project's noise requirements and goals. Contact us before your noise challenges become noise pollution problems.
-
product
Portable Emissions Analysers
Portable Automated Monitoring Systems, P-AMS or PEMS, such as Protea’s FTIR and TDL analysers allow for a wide range of industrial pollutants to be measured periodically or as a back-up to existing CEM systems.
-
product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.
-
product
Wood Moisture Meters
PeakTech Prüf- und Messtechnik GmbH
High quality wood and material moisture meter, which is characterized by its ease of use and universal applicability. The device has an LCD display, in which measured values of humidity and ambient temperature are displayed. In addition, it is equipped with an LED display, which enables a quick good-bad assessment of the measured values. When burning wood in a wood-burning stove with a high moisture content, the efficiency of the stove decreases, while at the same time the emission of pollutants, such as soot and fine dust, increases. In addition, there is a build-up of soot in the chimney, which can lead to a fire. Therefore, this device is ideal for wood storage, control during the heating season or use in construction.
-
product
Oil Quality Meter
Cooking oil is the mainly energy and nutrition source, and the cookingmaterial for daily life. Fried food is also favored as its unique taste . Withphysical and chemical reaction during the high-temp cooking process ,toxical chemicals will be produced. Currently, the traditional testing methodon cooking oil is mainly chemical method which is commonly used andconducted by professionals in the lab. But the lab oratory process alwaysproduces pollution and unnecessary waste . The Total Polar Material (TPM)values is the only acceptable standard which us ed for cooking oil testing.OS-27 is designed for cooking oil testing with safety and efficiency. It is ableto test total polar material (TPM) values in minutes and suitable for all kindsof cooking oil within high operation temperature.
-
product
Air Quality Analysis
Ambient Gas Monitoring: We offer a variety of analyzers for the ambient monitoring of the criteria pollutant gases, including CO, NOX, SO2, and others such as CH4 and CO2. Source Gas Monitoring (Emissions Monitoring): Experience reliable measurement in your process for emissions compliance every time.Ambient Particulate Monitoring: Experience our monitoring technology and gain the power to do more than just inform.Emissions Calibrators: For continuous monitoring of mercury in exhaust stacks, waste incinerators, and cement kilns, or multi-gas models to control the calibration of gas concentrations.
-
product
Residual Pollution Analysis System
Cleanalyzer
The Cleanalyzer is a high-end analytical system designed to examine particles on filters – a key procedure in performing reliable and reproducible evaluation of component cleanliness. High-resolution, optical zoom system (15µm and 5 µm version. High-resolution, fixed magnification optical system (35µm version).
-
product
GAOTek Three-Channel Leakage Current Tester
GT00YB00ZV
The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.
-
product
Regenerative Battery Pack Test System
17040
Chroma Systems Solutions, Inc.
The 17040 Regenerative Battery Pack Test System is a high precision system specifically designed for secondary battery module and battery pack test. It has an energy regenerative function to greatly reduce power consumption during discharge, and ensure a stable power grid without generating harmonic pollution on other devices – even in dynamic charge and discharge conditions. It is capable of recycling the energy discharged by the battery pack test back to the grid reducing wasted energy that traditional equipment discharges in the form of heat.
-
product
Continuous Emission Monitoring System
CEMS
CEMS, the “Environmental Eye” for Source Emissions.A Continuous Emission Monitoring System (CEMS) is an integrated system to measure fuel flow, dust, and concentrations of air pollutants such as SO2, NOx, CO, CO2, THC and O2 in accordance with the applicable regulations for the emission source.
-
product
Vehicle Electromagnetic Field Exposure Test System
SEM-400
Beijing KeHuan Century EMC Technology Co,.LTD
Vehicles are our daily public transportation. Electromagnetic pollution in vehicles has attracted more and more public attention. The newly revised compulsory standard GB27630-201X "Passenger Car Air Quality Evaluation Standard" intends to require the electromagnetic field in the car as one of the indicators, according to GB/T37130-2018 "Measurement method of vehicle electromagnetic field relative to human exposure" The measurement method is to measure the intensity of the magnetic field in the car. In the frequency range of 10Hz-400kHz, the electromagnetic field measurement result should meet the public limit requirements of GB8702-2014 for electromagnetic exposure.
-
product
EMF Detector
ElectroSensor™
This EMF detector is an unparalleled value that offers fast, reliable, and user-friendly measurements of electromagnetic pollution. Since man-made alternating current (AC) is different from naturally occurring EMF, some sources say that even extended exposure of as low as 2 milliGauss may be harmful. Fortunately, once EMF sources are identified with your ElectroSensor you can moderate your distance and exposure.
-
product
Geophysical Services
GF Instruments provides methodical research, near-surface measurements, consulting and services in: engineering-geological surveys (for civil engineering, dams and dikes monitoring, utility mapping, landslides). environmental monitoring and mapping (waste sites, leakages, pollution plumes). UXO surveys. hydrogeological surveys (ground water explorations and protection).
-
product
Flow Measurement for Liquids
We provide reliable flow measurement devices for clean, slight and heavily polluted media as well as a very wide variety of sensors. Our hydraulic flow measurement systems as well as our radar and ultrasound-based flow measurement systems are supplemented by hydrostatic or ultrasonic level measurements.
-
product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL D
The 72-7770 CAL D from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
product
Environmental Testing
Intertek Total Quality Assurance environmental laboratories test client samples around the world for trace chemical compounds and pollutants. Environmental chemists operate state-of-the-art analytical instrumentation, testing to government, regulatory, and industry standards. Analytical capabilities include trace and ultra-trace analysis for hydrocarbons, petrochemicals, metals, contaminants, and other materials.
-
product
Contaminometer
Conttest
Microtronic Microelectronic Vertriebs GmbH
Ionic contaminants can have a major negative impact on the reliability of assemblies. It therefore makes sense to check the assemblies for ionic contamination in the development stage and in the manufacturing process.The devices of the ConTTest series measure ionic pollution in accordance with international standards. The high-precision measuring system was designed to serve as a process control in production and to be used as a laboratory instrument in development and research.
-
product
Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.
72-2985
The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.
-
product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL DU
The 72-7770 CAL DU from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.