HORIBA, Ltd.
The HORIBA Group of worldwide companies provides an extensive array of instruments and systems for applications ranging from automotive R&D, process and environmental monitoring, in-vitro medical diagnostics, semiconductor manufacturing and metrology, to a broad range of scientific R&D and QC measurements.
- +81 75 313 8123
- +81 75 321 0752
- info@horiba.co.jp
- 2, Miyanohigashi,
Kisshoin
Minami-Ku, Kyoto 601-8510
Japan
-
Product
Easy Navigation Package for Optimal Raman Imaging
EasyNav
-
The new EasyNavTM package makes it easy to navigate through your image and acquire sharp Raman images in the blink of an eye, thanks to three new revolutionary applications: NavMapTM, NavSharpTM and ViewSharpTM. With the groundbreaking EasyNavTM package, it is fast and easy to navigate in-focus, in real-time, to identify the region of interest and obtain sharp, clear Raman chemical images. EasyNavTM has been tested and validated on a large variety of samples. HORIBA NavMapTM+ NavSharpTM+ ViewSharpTM apps can be used together or separately to deliver a powerful user experience for all Raman users.
-
Product
Automated Workstation
QPrep
-
QPrep is more than just a fancy syringe pump that is used to manually dispense reagent and just an autosampler that works with a separate syringe pump assembly. QPrep provides methodology-driven capability from a PC to handle precise reagent delivery for large number of samples in multiple racks.
-
Product
Explosion-Proof Gas Analyzer
51 Series
-
HORIBA’s 51 Series of explosion-proof analyzers provide safe, reliable and accurate measurements when analyzing flammable gases or operating in explosive environments. The 51 Series complies with IEC 60079. The 51 Series explosion-proof analyzers infrared allow for the measurement of CO, CO2, CH4 and other organic gases. The TCA-51 uses a thermal conductivity detector for H2 measurements and the MPA-51 and PMA-51 models integrate magneto-pneumatic and paramagnetic detectors for O2 measurements.
-
Product
Automatic Total Nitrogen/Phosphorus Monitoring
TPNA-500
-
More than 10 years have passed since the 5th Water Use Regulation was enforced in 2001. From the perspective on preservation of ambient water quality, it has become a matter of course for companies to be compliant with regulations and observe corporate compliance. Total nitrogen and total phosphorus monitoring in the future has the potential to lead to proactive enhancement of corporate value, in addition to compliance with regulations. While we propose technological innovations and improvements and LCC*1 reductions, we will pursue the future where regulations are strictly observed and corporate value is improved through monitoring.
-
Product
Miniature High Throughput Spectrometer
VS20-VIS
-
HORIBA designs and manufactures miniature high-throughput OEM spectrometers from 190 nm to 1700 nm for various applications. Thanks to a low stray light aberrations corrected concave holographic grating, the VS20-SYS platform offers in a 1.68 x 1.87 x 2 inches footprint a very reliable and robust spectrometer.VS20 OEM spectrometers can be fully customized in sensors, entrance, slit size, electronics board, interface, etc.
-
Product
UV-Vis-NIR Spectrometers
-
Innovative, customer-focused spectroscopic solutions covering spectral range of 180 -1700 nm
-
Product
Panel-mount Type Resistivity Meter (Four-Wire Transmission, 2-channel)
HE-960RW
-
HE-960RW connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.This resistivity meter is ideal for such applications as the high-precision water monitoring employed at ultra-pure water plants used in semiconductor manufacturing.They utilize newly designed, high-precision, high-stability temperature measurement circuitry and a vastly improved temperature compensation function, an important element for measuring the resistivity of ultra-pure water.
-
Product
Carbon / Sulfur Analyzer
EMIA-Pro
-
The EMIA-Pro, Carbon/Sulfur Analyzer is based on HORIBA''s vast knowledge of Non-Dispersive Infrared (NDIR) technology and our wealth of experience acquired from our EMIA series. EMIA-Pro offers improved the cleaning efficiency, enhanced user-friendly software, durability, operability and maintenance to ensure efficient measurements and its shortened measurement cycle time accelerates repetitive measurements up to 200 times, thus improving development and manufacturing speed.
-
Product
Custom Solutions - OEM Raman
-
For years, HORIBA Scientific’s OEM team has been the preferred, reliable and consistent supplier of OEM spectroscopy components. Our know-how in Raman (We are Number #1!) has made it into our miniature spectrometers and systems for portable Raman applications (Process control, Security, Pharmaceutical, Medical, Semiconductor…).
-
Product
Test Automation Software for Laboratory Management
STARS ENTERPRISE
-
STARS ENTERPRISE is a completely new generation of software from HORIBA, consisting of innovative web and mobile apps in a cloud-based platform. It enables you to seamlessly and completely integrate all your measurement systems, test beds and specimens, as well as on-board systems in the laboratory or in mobile road tests. The numerous apps in the STARS Enterprise system offer you a universal, flexible and scalable software solution for accomplishing your entire test automation activities, today and into the future.
-
Product
Optical Fiber Type Hot Phosphoric Acid Concentration Monitor
CS-620F
-
In 3D NAND manufacturing process, dozens of layers of SiO2 and SiN are deposited, and the SiN layer is selectively removed using hot phos.In this process, the desired etching rate can be achieved by controlling the concentration and temperature of the chemical solution.Previous products have difficulty to measure high temperature chemicals, but the CS-620F is able to measure at high temperatures up to 170 C degrees.
-
Product
Altitude Simulation
MEDAS
-
The MEDAS system is a compact altitude simulator that reproduces a wide range of environmental conditions. It allows for testing light- to heavy-duty vehicles, including Non-Road Mobile Machinery (NRMM). It is ideally suited for a range of testing applications, such as durability, RDE replication, emission tests and mapping as well as tests from component to vehicle level. The patented technology inside the MEDAS system allows dynamic changes on the simulated atmosphere with high accuracy. The system can also be moved between different test cells due to its compact design.
-
Product
High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring
IR-400
-
The IR-400 offers real-time monitoring of the chamber cleaning end point during the deposition process. By optimizing the cleaning process, the IR-400 reduces cleaning time and gas usage. This reduction in cleaning gas usage leads to a reduction in chamber damage and increases the life times of all the systems components.
-
Product
Static Image Analysis System Particle Size
PSA300
-
The HORIBA PSA300 is a state of the art turn-key image analysis solution. Seamless integration of Clemex's powerful particle characterization software and an automated microscope with high-resolution camera creates an intuitive, easy-to-use imaging workstation. Addressing a need in the field of particle characterization, the PSA300 is a versatile particle size and particle shape analysis tool that can be used in a wide range of applications in the pharmaceutical industries and material science. It is a turn-key solution for labs that want to maintain an analytical microscopy environment with minimum intervention by the operator yet still yield maximum detail in the results.
-
Product
Pitot Tube Flow Meter
PTFM-1000V2
-
The Pitot Tube Flow Meter, PTFM-1000V2 is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers to accurately measure highly pulsating exhaust flows with a sampling rate of 1kHz. This rapid capture rate ensures that any pulsations or exotic behaviour in an engine is measured, and the unique design of the PTFM pitot tube means reverse flows can be measured with the same guarantee of sensitivity. The interface can be run standalone with a laptop, or seamlessly integrated to run alongside an analyser system without adding any more steps to the test cycle process.