Filter Results By:
Products
Applications
Manufacturers
Platinum
See Also: Precious Metal, Gold, Platinum RTD
-
product
Cryogenic Temperature Sensors
Platinum
PT-100 platinum resistance thermometers (PRTs) serve an important role in both cryogenic research and industrial cryogenics applications.
-
product
Larger Size Chambers
Platinum
The ESPEC Platinum series are top quality temperature/humidity chambers in larger sizes for temperature cycling of 2 to 15°C per minute. High performance, reliable Scroll compressors(most units). One adjustable shelf with heavy-duty support rails. Non-metallic thermal breaks at doorframe and cable ports to eliminate exterior frosting or hot spots
-
product
Diode Temperature Monitor
SIM922
Stanford Research Systems, Inc.
The SIM922 Diode Temperature Monitor and the SIM923 Platinum RTD Monitor are designed to measure four sensors simultaneously. Based on the modular SIM platform, they provide high-performance and multiple-channel capability in a small footprint.
-
product
Portable XRF Analyzer
GoldXpert
XRF is a widely used, proven, and accepted method of chemistry analysis and determination of purity and fineness of precious metals. XRF analysis is a multielemental testing alternative that is quicker and less expensive than fire assay and chemical tests. XRF provides on-the-spot analysis of your silver, platinum, and PGM metals and impurities, making it an easy way to boost customer confidence and ensure dealer reliability.
-
product
Temperature Standards
ITS-90
The defining instruments of the ITS-90 (International Temperature Scale of 1990) are Standard Platinum Resistance Thermometers (SPRTs) and ITS-90 fixed-point cells. SPRTs are calibrated in fixed-point cells to provide the highest possible temperature accuracy. Primary standards offered by Fluke Calibration include: long-stem SPRTs; capsule SPRTs; triple point of water cells; metal fixed-point cells; maintenance baths and maintenance furnaces for fixed-point cells; standard resistors.
-
product
High-Temperature and High-PressurepH Electrodes
UltraDeg
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Dual MAX31865 PT-100 RTD to Digital Breakout
SEN-30202-PT100
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information. RTD devices may be wired in 2, 3 or 4-wire configurations using the 4-pin screw terminal input. The MAX31865 breakout is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance.
-
product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
product
RTD / PRT Platinum Sensing Resistor Inserts
RTD / PRT Platinum Sensing Resistor Inserts - Ceramic Sheathed, Pt100 & Pt1000 Inserts
-
product
Reference Thermometers
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
product
Tracking Index Test Apparatus
CX-L19
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Platinum and Nickel RTD Temperature Sensors
Accurate, repeatable and robust resistance temperature detector (resistance thermometers) sensor assemblies manufactured provide fast temperature response and can be applied in most temperature measurement and control applications.
-
product
Precision Thermometer
F252
ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.
-
product
Bluetooth® Enabled ORP/REDOX & Temperature Pen
UltrapenX2™ PTBT3
*Accuracy of ± 10 mV ORP*3 Calibration Options with Automatic Solution Recognition*Automatic Temperature Compensation in Calibration Mode*99.9% Pure Platinum Electrode*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type Battery (Included)*Waterproof
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
product
RTD Thermometers
Precision Platinum Temperature Sensor, High Accuracy With 0.01°C Resolution, Automatic Locked Push-pull Connector For Easy Connection, Large Back Light LCD
-
product
Ring Disk Electrode
This ring-disk type electrode developed by NTT Advanced Technology Corporation is a form of printed electrodes. Users can choose them from Carbon, Gold and Platinum applied versions. Available as a working electrode of radial flow cells, achieves complete reduction/oxidation on the center disk at ultra-low flow rate because of its fine coulometric electrolysis efficiency. This also enables to analyze subsequent reaction as well as identification and quantitation of the sample at the same time.
-
product
Particle Image Analyzer
DRK-7020
Shandong Drick Instruments Co., Ltd.
Determine the melting point to detect the purity of crystal material. Mainly used for determination of medicine, dyestuff, spice, and other crystal organic compounds’ melting point. Using photoelectric automatic detection, dot matrix image liquid crystal-display technology, and digital keyboard input. The instrument can measure three samples at the same time and has the initial melting, final weld automatic display, automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperaturesystem uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.
-
product
Temperature probes
Industrial platinum resistance thermometers 935 are suitable for use in the laboratory or on site. They can be used as a standard work on an oven or a calibration bath or as a precision sensor for our temperature indicators thermometers.
-
product
Nitrous Oxide Gas Sensors
The PST Dynament nitrous oxide (N2O) Platinum sensors are designed with patented non-dispersive infrared technology and contain all the necessary optics, electronics and firmware to provide a linearized, temperature-compensated output.
-
product
Probes/Sensors
Fluke Calibration provides high-quality secondary platinum resistance thermometers (PRTs); industrial PRTs; high-temperature, fast-response, and other special-application PRTs; thermistor standards; secondary thermistor probes; type R and type S thermocouples. These probes may be used for temperature measuring, temperature calibration, temperature monitoring and temperature validation.
-
product
Portable Multi-Function Recorder
Platinum 2.5K/Portable
The Platinum 2.5K Portable Multi-Function Recorder is packaged in a rugged case with quick connect interfaces for fast and simple field connection. Interface cables are provided with shrouded banana jacks that couple easily with a variety of measurement CT’s and voltage scaling devices offering complete flexibility for power utility and industrial use. The Platinum 2.5K Portable Multi-Function Recorder utilizes a 40GB solid state drive that eliminates the need for a mechanical hard drive and stores over 1,000 fault and disturbance records at once. It meets regulatory compliances including PRC-002-2.
-
product
Conductivity Electrode
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
product
Force Tensiometers
Sigma 703D
Sigma 703D is a simple and robust digital force tensiometer for accurate measurement of surface and interfacial tension (Platinum Du Noüy ring, Platinum Wilhelmy Plate), and density. Manual measurement of Critical Micelle Concentration (CMC) can also be conducted.
-
product
Platinum RTD Sensor - PT100 - 3 Wire 1 meter long
For precision temperature sensing, nothing beats a Platinum RTD. Resistance temperature detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature changes, basically a kind of thermistor. In this sensor, the resistor is actually a small strip of Platinum with a resistance of 100 ohms at 0C, thus the name PT100. Compared to most NTC/PTC thermistors, the PT type of RTD is much most stable and precise (but also more expensive) PT100's have been used for many years to measure temperature in laboratory and industrial processes, and have developed a reputation for accuracy (better than thermocouples), repeatability, and stability.
-
product
Temperature Calibration
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
product
Capillary-fill sensors
Zimmer and Peacock have launched the world's first capillary fill sensor for the Research and Development market, both academia and industry. We provide these capillary-fill sensors in gold, platinum and carbon.
-
product
Digital Melting Point Apparatus
DRK8011
Shandong Drick Instruments Co., Ltd.
DRK8011 Digital melting point apparatus is fully in line with ‘humanize’ of the design concept, using photoelectric automatic detection, dot matrix image LCD technology, digital keyboard input, each measuring one sample, measure three times the average of the melting point of the automatic strike, and has a melting, melting end automatically, melting curve automatic recording function. Temperature system uses high inearity make platinum resistance sensing element, the use of PID regulationtechnology to improve theaccuracy and reliability of the melting point, and with integrated electronic circuits to achieve rapid "starting temperature" setting and eight stalls to choose from linear "heating rate" Automatic Control. Instrument to establish communication with the PC via USB, save or print the graph, the instrument can be directly connected with the RS232 mini-printers, print graphs. The instrument uses Pharmacopoeia as a sample capillary tube.