handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.
See Also: High Voltage Meters
-
product
High Voltage Probes To Measure Primary Waveforms With A Power Analyzer
Volt Litewire
The Litewire is a true RMS meter designed for use by electric utilities to sense currents or voltage waveforms from the primary side of their distribution networks.
-
product
Active Differential Probe
DF-600
The DF-600 Differential Active Probe is a high input impedance and low input capacitance probe. It also supports extremely high frequency bandwidth, and high voltage input. It is designed using three OP amps, namely two FET buffer OP amps and a low offset OP amp. Therefore, even with long-term operations, the measured voltage will not drift. The voltage offset always approach 0 volts. (USB power supply should be 5V ±2%). The following diagram shows the circuit of DF-600.
-
product
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
AP031
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
High Voltage Differential Probe
DP750-100
Shenzhen Micsig Instruments Co., Ltd.
*The leads and probe are with shielded design, interface ends are integrated in a compact box, no need to twist the cables, leads to a lower noise floor and has less interference. *Support one-press Zero calibration and automatic overrange alarm.*Directly powered by Micsig UPI interface, realise auto scaling setup, can also powered by oscilloscope via USB cable.
-
product
Acute High Voltage Differential Probe, 20x/200x, 100MHz, 1400V
ADP2100
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
TightSight™ Clamp Meter, 660A AC/DC W/TRMS
61-765
*TightSight™ bottom display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Isolated Hall Effect Current Sensors
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
product
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Acute High Voltage Differential Probe, 10x/100x, 100MHz, 700V
ADP1100
*USB Powered (or Power Bank)*Bandwidth up to 10 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
High Voltage Probe
HVP-40
*MAX. Voltage : DC : 40KV, AC : 28KV, (50/60Hz only) CAT II.*1000MΩ Input Impedance.*Accuracy **DC: ± 1% to 20KV. ± 2% to 40KV. **AC: -5% to -10% (50/60Hz)*Division Ration : 1000:1*CE, TUV GS, UL, CUL, IEC1010
-
product
Injection Transformer
J2100A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
High Impedance Active Probes
12C
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
product
OverHead Lines Contact Voltage & Low Voltage Indicator
LVD-415
Standard Electric Works Co., Ltd
● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.
-
product
10:1 500 MHz 10 MOhms Passive Probe
PP005A
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MO. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Optically Isolated Measurement System
IsoVu
IsoVu offers complete galvanic isolation and is the industry’s first measurement solution capable of accurately resolving high bandwidth, low voltage differential signals in the presence of large common mode voltages. The stand out feature of IsoVu™ is its best in class common mode rejection across the entire bandwidth. Accurate differential measurements rely on a measurement system’s bandwidth, rise time, common mode voltage, common mode rejection capability, and the ability to connect to smaller test points to characterize devices that are shrinking in size and increasing in performance. Despite these requirements, advancements in test and measurement for power testing, EMI testing, ESD testing, and remote measurement capability have been minimal at best and have not kept pace with changing requirements. While differential voltage probes have had modest performance gains in regard to bandwidth, these probes have failed to make any substantial improvements in regard to common mode rejection, and connectivity. IsoVu is a leap forward in technology and is the only solution with the required combination of high bandwidth, high common mode voltage, and high common mode rejection to enable these differential measurements.
-
product
Power/Voltage Rail Probe. 4 GHz Bandwidth, 1.2x Attenuation, +/-30V Offset, +/-800mV
RP4030
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
product
High Voltage Differential Probe
ADF25A
Permits conventional grounded oscilloscopes to be used for the display and measurement of multiple floating signals with high common mode voltages
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Current Probe
DCP-BTA
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
product
High Voltage Probe
PD-28
Kusam Electrical Industries Limited
Most Digital Multimeters can measure AC Voltage up to 750 /1000V and DC Voltage upto 1000V DC. To extend the measuring range of the digital multi meter for low - power , high - voltage , high impedance circuits such as TV, Video Monitors.
-
product
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
High Voltage Probe
HVP-40M
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
product
Micro probes 1 MHz up to 6 GHz
MFA 01 set
The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
High Voltage Optically Isolated Probe, 350 MHz Bandwidth. Includes soft-carrying case.
DL03-ISO
The DL-ISO enables highest confidence in GaN and SiC device characterization with highest accuracy, best signal fidelity, and comprehensive connectivity.
-
product
T3 Low & High Voltage Differential Probes
T3 Series
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Replacement Pincer Clips for High Voltage Differential Probe
PK-HVA-02
Replacement Pincer Clips for High Voltage Differential Probe
-
product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.