product
Digital LOOP/PSC/EARTH Tester
1824 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.
-
product
Detector of Earth Faults on Multi/Single-Core Terminations
CableTroll 2310
CableTroll 2310 is an indicator for detection of earth faults (PtG) on multi-core and single core cable terminations. The unit uses NorTroll type current sensor (CT)
-
product
Medical Leakage Current Tester
2675Y
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Battery Boxes Testing Equipment
Battery boxes can be tested for faults by placing the box on a metal plate. By applying a test voltage to an electrode inside the box, the moulding can be checked thoroughly - particularly at the injection points - and any faults found. Defects will be identified by a spark passing from the electrode, through the defect itself, to earth (the conductive material placed outside the battery box.
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.
-
product
240V Socket Tester Check Plug
CP501
The most popular socket tester available - detects 28 fault conditions.
A quick and easy way to ensure that 13A sockets are correctly wired, indicated by 3 bright long life LEDs.
Wiring faults are indicated by one or more of the LEDs failing to illuminate, with the pattern of lit LEDs indicating the type of fault detected. This fail-safe system means that any LED not lit indicates a fault. The robust ABS housing has a sculpted shape for easy removal and there is a look up chart on the tester for quick fault diagnosis.
The plug induces less than 5mA of earth leakage, well below RCD trip thresholds.
-
product
Line Indicators
LineTroll
Fault Passage Indicators to locate short circuit and earth faults.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-60NK
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
product
Earth Fault Indicator
The Sensorform Range of Earth Fault Indicators detects earth faults & short circuit faults on underground cables. A number of options are available for enclosure type, power source, indicator type, reset method, trip-level selection, and remote indication.
-
product
DC System Earth Fault Detector
PDF1000 / 781
Wuhan Huatian Electric Power Automation Co., Ltd.
Our company's DC system grounging fault tester is a new generation of products. It can be applied to dc system measurement of any voltage level.
-
product
Detection of Earth Faults (PtG) and Short Circuit (PtP) Faults
CableTroll 2330
CableTroll 2330 is an indicator for detection of earth faults (PtG) and short circuit (PtP) faults on multi and single core cable terminations. The unit uses NorTroll type current sensors.
-
product
Surge Voltage Generator
SSG 500
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
product
Multifunction Tester
EASYTEST
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Current Clamps and Sensors
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
product
High Impedance Busbar Differential Relay
MIB
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
product
20Hz Injection Kit Monitoring System
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
product
Earth Tester
TAURUS PRECIOHM ET
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20M
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Current measurements for small DC motor*Convenient +5V single polarity power supply
-
product
Loop Testing
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
product
Electrical Safety Test Equipment
Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.
-
product
Cable Indicators
CableTroll
They are installed on Ring Main Units in distribution substations. They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indications for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communications modules.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Fault Passage Indicator for Lines
LineTroll R400D
LineTroll R400D Fault Indicator indicates earth- and short-circuit faults and can distinguish between permanent and transient faults. The indicator has two sensors and use both the electrical field and the magnetical field to detect faults on all three phases.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
Earthing Resistance Tester
JYD-10A
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
product
Current Protection Relay
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.
-
product
Ground-Fault Products for Solidly Grounded Systems
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
product
Relay Test Set
RNT-5A
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.