Filter Results By:
Products
Applications
Manufacturers
Anechoic Enclosures
Enclosures that dampen rf or sound reflection within and stop exterior noise.
See Also: Enclosures, RF Enclosures, Shielded Enclosures, Anechoic Boxes
-
product
Anechoic Chambers
Eckel Noise Control Technologies
Anechoic Chambers are echo-free enclosures with a sound energy absorption level of 99% to 100%, or a reflected sound pressure level of 10% or less. The frequency at which the energy absorption drops below 99%, or the pressure reflection exceeds 10%, is known as the low-frequency cut-off. Sound absorption is obtained by lining the walls, ceilings, and floor with wedges or other sound absorbing elements or SuperSoft panels, depending on performance level required and cut-off desired.
-
product
Antenna Testing Services
Our chamber measures 28' x 14' x 14' with 12" to 36" pyramidal anechoic absorbers and is fully shielded using a dual layer metal enclosure. Our test chamber is designed to for frequencies ranging from .700 to 6.00 GHz.
-
product
Electromagnetic anechoic box/Shield box/Anechoic chamber
The necessity of a wireless system test has risen by the spread of recent wireless telecommunication equipment as shown in cellular phone, wireless LAN, RF-ID tag and ETC (Electronic Toll Collection system). It is necessary for a wireless test to be performed in anechoic environment in which an external noise is intercepted and a radio wave does not reflect internally. An anechoic chamber (room version of a shield box) is proper facilities but needs a wide space and a huge cost. Especially, the equipment under wireless system test on the production line can not radiate any signal radio wave outside before approval. The shield box satisfies these conditions.
-
product
Advanced Reconfigurable Modular OTA RF Test Enclosures, ≥100 DB Isolation, 300 MHz - 90 GHz
dbSAFE ARMOR
The dbSAFE ARMOR series of shielded boxes are cost-effective solutions for OTA testing in the mmWave spectrum. Providing a shielded, fully anechoic test environment, these RF test enclosures ensure stable and repeatable measurements over a wide frequency range (from 300 MHz to 90 GHz).
-
product
Hand-In Type Electromagnetic Anechoic Box (Shield Box)
MY3720
Suitable for weak electric field resistance test, out-of-service test or digital forensics for smart phone, tablet terminal or mobile PC ! !DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
product
Hand-In Type Electromagnetic Anechoic Box (Shield Box)
MY3710HS
Higher shielding performance than MY371080dB. Suitable for weak electric field resistance test, out-of-service test or digital forensics for mobile phone, smart phone or tablet terminal! DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
product
Broadband Antenna
Vivaldi
The dbDIRECT Broadband Antenna features a broad frequency range of operation, high gain, small form factor and directional radiation pattern, making it highly attractive for widespread use in test and measurement of emerging wireless technology devices and radars. Contrary to conventional Vivaldi antennas limited to operating only at higher frequencies, the dbDIRECT Broadband Antenna design is optimized to operate at a frequency as low as 700 MHz up to 6 GHz. This lightweight and compact antenna design provides excellent matching over a broad frequency range.The antenna is designed to be placed in a DVTEST's portable anechoic chamber such as the dbSAFE enclosures for OTA (Over the Air) testing of DUTs. The antennas can be mounted in fixed positions to facilitate repeatable results. When used in conjunction with a rotary positioning mechanism, customers are able to detect the highest point of power sensitivity for enhanced accuracy and repeatability in measurements. In this configuration, both the antennas and DUTs can be positioned in order to facilitate the measurement.
-
product
Anechoic Chamber
Wedge:The acoustic absorptivity of sound-absorbing materials used in anechoic chamber must be greater than 0.99. In anechoic chamber, gradient absorption layer, wedge or conical structure are often applied with glass wool and flexible foam as its sound-absorging materials. Anechoic Door: The design of rotatable door can affect the whole function of anechoic chamber. Therefore, it's crucial to combine steel plate and sound-absorbing cotton in the door, which is exactly our design.Acoustic Insulating Material:Applying high-density materials to enclose external noise. Damping materials: Using spring, rubber and cotton to enhance damping capacity.The Anechoic Chamber conforms to GB/T 6882-86 and ISO 3745 specifications.
-
product
Anechoic chambers
The anechoic chambers are built up as a modular construction. Due to individual modules any size of chamber can be manufactured. Big chambers may require an outer supporting structure or alternatively the shielding material can be attached direct to the building. The absorbers are fixed to rails bars or wooden base construction which is inserted into the shielding modules.
-
product
Enclosures
No input device can perform optimally if its enclosure or housing isn’t perfect. Successful products rely on enclosures that are built to high quality standards and perfectly suited to their intended applications and operating environments. Hoffmann + Krippner can provide inexpensive standard enclosures with modifications in size, shape, and finish, or complete bespoke solutions using state-of-the-art production capabilities. For both metal and plastic enclosures and prototyping or large-scale production, we and our network of vertically integrated partners can guarantee a complete one-piece input solution produced according to either standard or customer-specific designs.
-
product
Anechoic Chamber
Beijing KeHuan Century EMC Technology Co,.LTD
(7m × 4m × 3m) RF shielding EMC laboratory (anechoic chamber) is constructed by attaching ferrite tiles and microwave absorbing materials after the RF shielding room is built (7m × 4m × 3m) The simple 3m test distance EMC laboratory can perform EMC tests in the frequency range of 30MHz-18GHz.
-
product
Anechoic Chamber
EMC-3
A 3 meter test range ensuring fully compliant Emission and Immunity testing. Ferrite and hybrid pyramidal absorbers are combined in a unique pattern within a SmartShield high performance chamber. Operating at a 3m test distance, this chamber is compliant to CISPR-16 with a measurement zone diameter of 1-2 meters.
-
product
Extra-Rugged Enclosures
Fiber Lab 800HE
Fiber Lab 800HE from M2 Optics Inc. offers an extremely rugged testing platform for engineers and technicians working with fiber optic products and networks. Built to endure rough handling around the lab or travel, it can hold up to 30km of optical fiber with your choice of custom length.
-
product
Racks & Enclosures
You want optimal performance, easy deployment and scalability for your IT systems and data centers. Our data center racks, cabinets and enclosure solutions provide support and protection to your critical IT and facilities. As you grow your business, our modular solutions and mobile designs adapt to your space and budget needs.
-
product
Panels And Enclosures
Schweitzer Engineering Laboratories, Inc.
SEL panels and enclosures offer advanced protection, control, automation, and communications solutions, all at varying levels of customization. Select from ship-from-stock or configure-to-order panels for expedited lead times, or partner with Engineering Services to develop your own custom panel or enclosure.
-
product
Video Tracker Enclosure
CAATS3
Compact, rugged enclosure provides interfacing for Abaco Systems’s smaller video trackers operating in airborne environments.
-
product
Enclosure Accessory Kit, Gas Spring for Sloped Enclosure
410114133
The sloped enclosures come capable of having a Gas Spring accessory installed on the left, right or both sides of the enclosure. The enclosure comes standard with one Gas Spring accessory on the right side.
-
product
Enclosures
VPC offers a variety of options to customize standard enclosures to meet any application need. Use VPC's Customer Wirelist Template to quickly communicate your overall requirements. VPC can provide options such as cutouts, secondary connectors, silk screening, engraving, and much more. Contact a Field Application Engineer for assistance designing a custom enclosure to meet your test needs.
-
product
Tapered Anechoic Chamber
It’s nearly impossible to perform VHF/UHF measurements in a rectangular chamber. In the 1960’s Emerson determined that tapering one end of an Anechoic Chamber would cause the chamber to act like an indoor ground reflection range.
-
product
Enclosures
Explosion Proof and NEMA Enclosure Kits
Available • Explosion Proof • Explosion Proof Large • Enclosure Kit, NEMA 4X, 14x12x8, Fiber Glass, w/Swing Out Door & Window • Enclosure Kit, NEMA 4X, 10x8x6, Fiber Glass, w/Swing Out Door & Window • Enclosure Kit, NEMA 12, 8x6x6, Steel • Enclosure Kit, NEMA 4, 10x8x6, Steel • Enclosure Kit, NEMA 4X, 10x8x6, Fiber Glass, w/Window
-
product
RF Shielded Test Enclosure
JRE 0814
Testing tall devices? The 0814 stands up to any test up to 18 GHz! Featuring a wide swing open door with durable latch handle, this enclosure finds wide use in the WiFi test environment. Two shielded vents provide excellent cooling and optional fan(s) are available for those hot products. Tough 'honeycomb' vents maintain shielding effectiveness throughout the frequency range. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness.
-
product
RF Shielded Test Enclosure, Large, Yet Benchtop Enclosure
JRE 2525
Originally designed for testing rack mounted RF Sensing equipment, the roomy JRE 2525 is ideal for large wireless devices such as; Rack Mount Mesh Network AP's, Cellular/LTE/4G Base Stations, Wireless Laptops, Test Fixtures for testing Large RF Modules, and other large RF devices.
-
product
Environmental Enclosures
TSI’s DustTrak™ Environmental Enclosure models 8535 is designed to protect the standard DustTrak models (8530, 8533, 8530EP and 8533EP) when monitoring outdoors or in hazardous environments
-
product
Wall-Mount Enclosure
Model BOX
Model BOX is a wall-mount / bulkhead enclosure which provides environmental protection to IP65 / NEMA-4X. It comes with a 1/8 DIN panel cutout (45 x 92 mm) and can be used with 1/8 DIN instruments with a depth up to 134.5 mm (5.30"). This includes all 1/8 DIN instruments sold by Laurel Electronics.
-
product
Switch and Connection Enclosures
Where many sensors are permanently located on a machine it is useful to terminate all the connections at one location where the sensor outputs can either be analysed or relayed to a remote data system with multicore cables.
-
product
HV Enclosures with Integrated Safety Test
The HV test hood according to Performance Level e (ISO 13849-1), developed by us according to the EN50191 standard (erection and operation of fixed and temporary electrical test installations), offers the highest safety for the operator. The large test chamber is enclosed with a hood made of sturdy, highly insulating and transparent plastic. During the test, there is a clear view of the test specimen. A signal light visually indicates safe opening when the light is “green”. “Red light” symbolises danger, the hood cannot be opened due to the safety interlock. The safety switch also ensures that the hood cannot be opened during the test. This means that the test hood fulfils all the required specifications for compulsory contact protection.
-
product
Anechoic Chamber room for Automotive components
Anechoic Chamber room of most suitable Automotive devices EMI/EMS test of the method of ALSE, which meet the global standard like a 2004/104/EC, several emmission standard like a CISPR25 which automotive manufacturers in EU/USA refer to, Immunity standard like a ISO11452 and others for the Automotive devices.