Product
Auto Calibration for Load & Extensiometer
-
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.
-
Product
Fracture Mechanics Clip-On Gages
Model 3541
-
Jinan Testing Equipment IE Corporation
The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Circumferential Extensometers
Model 3544
-
Jinan Testing Equipment IE Corporation
Designed for concrete and rock compression testing or for compression tests on other large samples. This model may be used simultaneously with the Model 3542RA axial extensometers.
-
Product
High Temperature Axial Torsional Extensometers (1200 C or 1600 C)
Model 7650
-
Jinan Testing Equipment IE Corporation
Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.
-
Product
High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)
Model 7651
-
Jinan Testing Equipment IE Corporation
Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.
-
Product
High-Temperature Extensometers < 1000°C Capacitive
2632 Series
-
Is typically used in hot tensile applications with tube type furnaces and consist of a separate measuring unit and suspension arm assembly. The measuring unit uses an LVDT with a fixed travel that remains outside of the furnace, the arms are located mostly inside of the heating system and attach the specimen to the measuring unit.
-
Product
Video Extensometers
-
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
Product
Averaging Clip-on Extensometer
2650 Series
-
The Instron 2650 Series Biaxial Extensometers are ideally suited for testing a wide range of materials, including polymer matrix composites, metals, and plastics over a range of temperatures. Two sensors measure axial strain on opposite sides of the specimen. Versions are available which provide either a single averaged axial output or 2 independent axial outputs. The extensometers meet the calibration requirements of ASTM E83 class B1, ISO 9513 class 0.5, and ISO 527.
-
Product
Force Sensors
-
Here at Flintec, our force sensor range provides solutions that integrate effectively into a wide variety of industrial applications. They include customized load pins, extensometers, torque sensors and a range of miniature force sensors.
-
Product
Software
-
Tinius Olsen provides software to meet your R&D and quality control needs, working simply, efficiently and accurately. Horizon makes all your testing as effortless as it should be. It carries out your testing and seamlessly integrates with your processes. VSS works with Horizon to control your video extensometer testing.
-
Product
One-Touch, Strain Gauge Extensometers
SSG-H Series
-
The SSG-H series of strain gauge extensometers are compliant with ISO, JIS, and ASTM tensile test standards for hard plastics and metal materials Featuring a wide elongation measurement range with the ability to measure using small gauge lengths, these lightweight, clip-on strain gauge extensometers attach to both rod and flat plate specimens.
-
Product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
-
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.