Filter Results By:
Products
Applications
Manufacturers
Loop backs
connect input to ouput to test I/O loop.
-
product
IndustryPack system trouble shooter
IP-DEBUG-IO II
IndustryPack system trouble shooter providing testpoints on all of the IP IO signals. Loop back is as easy as wire-wrap. Custom feedback signals are supported with socket and power connector support. Now with 2 ribbon cable connectors to support in system debugging.
-
product
Mezzanine System
5041
ECM P/N 5041 provides eight channels of RS485 / RS422 I/O with fixed 120 ohm termination for each channel. Speeds are up to 30M bits per second. All channels power up as inputs. Also transceiver inputs are always enabled for loop back diagnostic use when the outputs are enabled. Software can enable outputs on a channel by channel basis.
-
product
Telemetry Simulators & Test Transmitters
Command Data Telemetry Simulators offer a dynamic way to create or change a PCM data stream on a word by word basis on the fly. This PCM data stream can be used to modulate an FM or SOQPSK RF output at S-Band or L-Band. In addition to simulating a new telemetry stream, the telemetry simulators can play back and loop an archived data file (which can also be changed on the fly) or create pseudo-random patterns.
-
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
Loop A Line
TX916
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.
-
product
Main Effects
The Analog Multi FX is an Authentic Analog Multi Effects Pedal equipped with everything you need to get the job done on stage and in the studio. It’s got a Switchless Optical Wah, Distortion, Effects Loop, Stereo Chorus, and Echo. Even better these are reissues of classic Morley circuits leading all the back to the 1970’s. And speaking of the 70’s it also has a new finish that pays homage to the original chrome Morley pedals. It’s Heavy-Duty spun stainless steel that’s Built like a Tank and looks great under stage lights. Each one is hand spun at our Illinois facility.
-
product
Wire Harness Tester
Panther4HT Master- Slave DSU
Qmax Test Technologies Pvt. Ltd.
The Master- Slave DSU based Panther4HT Wire Harness tester is designed for testing and verifying electrical connections in a cable, harness, backplane or any other wired assembly. It offers unique Qmax MASTER - Slave concept and SATELLITE UNIT Options to avoid looping back of cable to the ATE. All Satellite Units communicates the measurements through LAN interface which is very useful for on-board applications in Aircrafts / Ships and similar applications where large cable looms are used. This innovative concept will eliminate the long adapter cables and hence storing, maintaining and re work of these kind of cables are avoided. Furthermore single Master Controller Unit (MCU) is used to control not only all the satellite units , but also communicate with all satellite units through Ethernet Communication port. A single reference Cable is used to link the all the satellite units with the Master Controller in controlled loop manner is a value add to the product.
-
product
Transponder Panel with GNS/GTN Interface
TA-330XP
This transponder panel is layed out to accommodate thecurrent Mode S panel mount units. The transponder caninterface with a GNS or GTN series radio for a morecomplete test of the transponder functions. The panelalso includes altitude, suppression, loop back and thestandard ARINC 429/RS232 interfaces as well. The panelcomes with both a digital voltmeter and ammeter.
-
product
Rain Test Chamber - Twin Shower
The Drive-In Rain Test Chamber is generally used to conduct whole body testing of assembled vehicles under different rain test procedures to study and estimate their structural degradations and destructions induced by rain/water. The twin shower area with 1.1 million litre & 0.35 million litre volume is enclosed in a shed where arrays of pipes are interconnected to form zones to ensure the uniform spraying as per JSS 55555 test standard. The water gushes through the nozzle at a flow rate of up to 288 cu m/hr and the test chamber water collection system have a central grating with sufficient slope to collect the sprayed water during operation and circulate it back to the water reservoir to ensure close loop circulation.
-
product
Precision Current Loop Calibrator With Hart Communications
LC-110H
The Martel LC-110 and LC-110H are mA (loop) calibrators designed to take the loop calibrator class to the next level. The new LC-110 series feature a user friendly interface with dedicated buttons and a rotary encoder (Quick-Set Knob). This combination drastically reduces the time it takes to measure, simulate, or source both voltage and current and power up a loop. The rugged ABS plastic case is contoured to easily fit a technician's hand and the large back lit graphics LCD is best in class. The LC-110H differs from the standard LC-110 in that it incorporates HART communications and supports a select set of the HART universal and common practice commands. This unique feature allows the LC-110H to be used as both a loop calibrator and communication tool.
-
product
Back Pressure Tester
TU29P
Enables Technician to test exhaust back pressure thru oxygen sensor. Oxygen Sensor adapter includes M12 & M18 thread.Special Gauge has two multi-colored bands - idle and 2500RPM, with pressures shown in PSA and bar.
-
product
Back and Forth Scratching Tester
WGQ-60
Shanghai Dean Electrical Co., Ltd
Executive standard: NEMA、JIS; Inspection standard: JB/T4279.15-2008Used to detect the scraping resistance of coating and cable insulation layer of flat wires of 0.800~5.600mm (narrow side) and the silk and enamel covered round wires with nominal conductor diameter of 0.100~5.000mm;Application of SCM control allows for fast operation and strong anti-interference capacity;Sample support table allows for parallel rise and fall, maintaining close contact between the entire plane with sample;Scratching needle is vertical to the paint scraping direction and parallel with sample supporting table;When film is scratched and the action current is ≥5mA, painting scraper would automatically stop scraping;LED would automatically display the number of scraping.
-
product
Single Loop Controller
1800+
The 1800+ controller is an evolved product from the West N8100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
Monitoring Loops
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
product
Automotive Back Probe Pins
142-5
Flexible 1.5 inch silicon pins provide easy back probing connections for DMM and Scope measurements
-
product
Loop powered Moisture Analyzer
PLMa
Multifunctional Multi-Purpose Cost Effective, easy-to-use dew point sensor, dew point probe
-
product
Loop Antennas
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
product
8 Connector-Hole Back Extension
9401-BE
Semi-enclosed version of the cabling "doghouse" for the Hawk/PC chassis with rear panel punched to accommodate 8 50/37 pin d-sub connectors. Space is provided to mount the standard DG-style 100 pin edge connector paddles.
-
product
Single Loop Controller
1166
The 1166 is a powerful, single loop profile controller for complex processes. It offers profiling capability with 4 programs each of 16 free format segments making it a leader in its class.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
U Type Glow Wire Loop
IEC60695-2-10
Shenzhen Chuangxin Instruments Co., Ltd.
Thermo resistance, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a standardized test platelet made of plastic (or other materials) for a prescribed period of time under precise test conditions.
-
product
RCD Loop Line
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
product
Open Loop Current Sensor
K03
The K03 series is a current sensor based on the Hall effect. It enables the electronic measurement of direct, alternating or pulsed currents as well as their combinations with galvanic separation between primary (high current) and secondary circuits.
-
product
4-20mA Current Loop D/A Converters
ADI integrated solutions combine both the D/A converter and driver in one chip to provide the required output directly from the digital domain. Analog Devices’ portfolio of leading industrial D/A converters and drivers provides a range of programmable output ranges from standard 4 mA to 20 mA for current loop communication to ±10 V for actuator control. ADI industrial converters offer considerable control functionality and advanced on-chip diagnostics to maximize system uptime, as well as eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
product
Single Loop Controller
1160+
The 1160+ controller is an evolved product from the West N6100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Temperature Loop Control Setup
ULP-27
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
LOCAL LOOP SIMULATOR FOR TR-114 INCLUDING BRIDGED TAP
458-LM-A1-30-TR114
The Model 458-LM-A1-30-TR114 Local Loop Simulator for TR-114 is the ideal solution for simulating test loops as defined in TR-114 and includes a Bridged Tap. In addition, it is also suitable for ADSL, ADSL2, ADSL2+, and VDSL2 chip/modem/DSLAM testing of straight loops out to 24,000