Ground Fault Tracers
find an electrical cable's current leakage or fault.
See Also: Tracers, Curve Tracers, Cable Tracers
-
Product
USB-8501, 1-Port, Low-Speed/Fault Tolerant, USB CAN Interface Device
786306-01
-
The USB-8501 is a low-speed controller area network (CAN) interface for developing applications with the NI‑XNET driver. The USB‑8501 is powered over the USB bus and does not require external power. It excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals such as bus monitoring, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex applications. The USB‑8501 is available with a three‑pin COMBICON synchronization connector for triggering and synchronizing the internal hardware timebase with other devices.
-
Product
Programmable Ground Resistance Tester
-
AllWin Instrument Science and Technology Co., Ltd.
Executive test in 40A/60A of UL60950-1Test resistance range 0~510m ohmOutput current range 5~40A
-
Product
Ground Grid Tester
GGT Series
-
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.
-
Product
Curve Tracer
Series 5000C
-
Our curve tracers are used worldwide for high volume production, quality control and final testing of descrete semiconductor devices. Provided with an Intel based single board computer(SBC) and Windows based software, the Scientific Test curve tracer is highly reliable, extemely fast, very easy to operate, and provides quick creation of digital curves for data storage and intuitive manipulation.
-
Product
Air Core Neutral Grounding Reactors
-
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
Product
Earth Ground Testers
-
TES Electrical Electronic Corp.
Capable of measuring earth voltage. Data hold function. Auto power off function. The timer operates automatically about 10 minutes with the "test button switch are pressed to keep the tester power on.
-
Product
Ground Leads Continuity Tester
-
Weshine Electric Manufacturing Co., Ltd
1. The new power supply technology is adopted in the grounding down lead conduction tester.2. It has the characteristics of small size, light weight, large output current, good repeatability, strong anti-interference ability and protection function. 3. The whole machine is controlled by single chip microcomputer, which has a high degree of automation. 4. The instrument has high precision and easy operation. The maximum current is 10A.
-
Product
Mobil Cable Test and Fault Location System
SWG-12 (SWG-32)
-
• testing cable insulation with DC (rectified) voltage up to 32 kV;• conditioning faults by burning faulty cable insulation with current up to 100 mA;• pre-locating cable faults with the reflectometer RIF-9 based on the pulse reflection method (TDR), voltage wave oscillation method (DECAY), impulse current envelope (ICE) method and arc reflection method (ARC / ARC multi-shot);• pinpointing cable faults with the acoustic method with up to 2000 J surge wave generator and a suitable signal receiver.
-
Product
Wire Tracer
-
*Detect through the shielded cable*Instantaneous finding of AC current*Tracing cables*Monitoring current status in applicances*Compares the AC current*Tracing cables inside the wall*Locating underground cables*Detects magnetic field*Low voltage high current detection
-
Product
AC Hipot w/ Ground Bond Test Capability
HypotULTRA® Series
-
In a world where data is king, HypotUTLRA improves traceability with on-board data storage and allows you to automate hipot testing with a variety of communication interfaces. Increase efficiency with our direct barcode scanner connection and intuitive touch screen interface. Models 7804 and 7854 are a 4-in-1 solution with the addition of 40A AC Ground Bond test capability added to HypotULTRA's already impressive feature list. HypotULTRA is a dielectric analyzer designed to take your production line to the next level.
-
Product
Earth Ground Testers
-
Fluke''s family of earth ground testers have been built to address the entire spectrum of ground testing methods from the basic to the most advanced. Our testers have been designed to be accurate, safe and easy to use. We provide quick and precise resistance measurements through several test methods: 3- and 4-pole Fall-of-Potential testing, selective testing, stakeless testing and 2-pole testing. Detailed application information can be found at the Earth Ground Solution Center.
-
Product
PXI-8511, 1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module
780686-01
-
1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module—The PXI‑8511 is a fault-tolerant Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. The PXI‑8511 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimize message latency and freeing host processor time for processing complex models and applications.
-
Product
Visual Fault Locator
TM191
-
TM191 series visual fault locator is used for the measurement in single mode or multi-mode fibers. It features a rugged design, a universal connectorand an accurate measurement
-
Product
Ohm-Stat Ground/Circuit Tester to Test ESD Ground
-
Tests ground for all 110v electrical circuitsWill determine the status of all electrical groundsEasy to use LED lightsWarranteeProduct conforms to the ESD S.20.20 spec standardsIdentify electrical problemsUsed with the Ohm-Stat RT-1000 resistivity meter
-
Product
PXI Fault Insertion Insertion Switch Modules
-
Our PXI Fault Insertion Insertion Switch Modules feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect – all of which can simulate connectivity problems in the system.
-
Product
Cable Fault Location System
BAUR Syscompact 2000 Portable
-
Cable fault location system Syscompact 2000 portable. The cable fault location system Syscompact 2000 portable is used for precise location of high-resistance and intermittent faults in low and medium voltage cables.* Fast and reliable* Precise, dependable cable fault location* High performance high voltage unit* Integrated proven cable fault pre-location methods
-
Product
Visual Fault Locator
TW3105
-
Techwin(China) Industry Co., Ltd
Pen Type is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network.