Filter Results By:
Products
Applications
Manufacturers
-
product
Infrared Moisture Analyzer
LD-LIMA-A10
Infrared Moisture AnalyzerLD-LIMA-A10is an online, fast, continuous measurement and non-contact measurement device with measurement distance range of 20 to 40 cm. It provides automated control and 4 to 20 mA current signal. This IR Moisture Analyzer emits different wavelengths of infrared light (4, 6, 8, 10 beam) to calculate the moisture content of the measured object. Designed with long-life high-speed brushless motor, imported high response infrared sensors, information processing chip FPGA + DSP + ARM9 combination, to attain real time data, improved stability and precision.
-
product
Trace VOC Analyzer
PTR-TOF 6000 X2
The new PTR-TOF 6000 X2 is our premium PTR-TOF trace VOC analyzer. We conceived a unique system comprising of a novel high-resolution TOF and IONICON’s PTR technology with the new “X2” features, for the ultimate PTR-TOFMS experience. X2 combines the latest generation of performance enhancing tools incl. the ION-BOOSTER funnel as well as the hexapole ION-GUIDE. The ion funnel focuses the ions into the hexapole ion guide which results in nearly lossless transmission of an extremely focused ion beam into the TOF mass spectrometer. This increases the sensitivity dramatically and also improves the instrument’s mass resolving power. Utmost resolution, sensitivity and lowest real-time detection limit are now available in a robust, transportable platform that is smaller and lighter than previous products.
-
product
Energy Dispersive X-ray Fluorescence Analyzer
X-5000
HORIBA continues it's innovation in the petroleum market by proudly teaming with Olympus Innov-X to promote the X-5000 Mobile XRF Analyzer. The X-5000 is a rugged, fully integrated closed beam portable EDXRF system that offers the power and performance of a traditional benchtop XRF, but is designed for transportable operation. Using a Silicone Drift Detector, low PPM detection limits can be achieved for many elements in a variety of sample types and matrices. Applications include fuels, additives, and wear metal oils to crude oils, water, coke, and coal allow this easy to use analyzer to be a fast, flexible solution to traditional testing methods.Detectable elements to concentrations of 100% are: Aluminum, Antimony, Barium, Cadmium, Calcium, Chlorine, Chromium, Copper, Iron, Manganese, Molybdenum, Nickel, Phosphorous, Potassium, Silicon, Silver, Sulfur, Tin, Titanium, Vanadium, and Zinc.
-
product
*Measure Focus Spot
The focus spot analyzer can measure your laser beam power distribution and focal spot size of wavelengths from 266 – 1100nm. The average power can be from <1 to 400 Watts and the focal spot can be as small as 25µm. The FSA can also be used to measure how the focal spot shifts with power during its critical start-up phase.
-
product
Gas Filter Correlation CO2 Analyzer
Model N360
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Chlorine Dioxide Analyzer
optek’s chlorine dioxide (ClO2) analyzers are inline devices designed to measure real time ClO2 solution strength and/or ClO2 gas concentration . These analyzers can be designed to accommodate virtually any measuring range regardless of the stream’s phase. Operationally, the analyzer passes a white light beam through the ClO2 stream to be monitored, where light absorbance is measured at two distinct wavelengths.
-
product
Gas Filter Correlation CO Analyzer
Model N300
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
*Pulse Characterization Sensors
Pulse Characterization Sensors provide the ability to see and measure the temporal characteristics of pulsed and CW laser beams. Ophir Fast Photodiode Detectors are designed to convert optical signals into electrical signals which are then measured with third-party instrumentation such as oscilloscopes and spectrum analyzers. Accessories are available to connect to IS6 integrating spheres or fiber optic cables. Attenuating filter accessories are also available to increase their dynamic range. Different models offer silicon, UV enhanced silicon and InGaAs PIN photodiodes, covering a combined spectral range of 193 nm to 1700 nm. Rise times range from 25 picoseconds to 3 nanoseconds. The fast rise times are achieved by an internal reverse bias voltage circuit. Power is supplied by internal batteries and/or an external power supply depending on the model. Detectors should be connected to a 50Ω impedance in order to maintain their nominal rise times. They can be connected to higher impedance loads, but this will result in a significant increase in the rise time. If higher output voltage is required, it is recommended to connect the detector to a trans-impedance amplifier with an Input impedance of 50Ω
-
product
Amplitude Detectors with Isolators
Full band waveguide detectors are GaAs beam lead Schottky diode-based detectors that are specially designed for millimeterwave network analyzer applications. With a proprietary circuitry design and careful diode selection, these zero-biased detectors exhibit high sensitivity and extremely flat output characteristics. The below standard offering covers the frequency range of 18 to 170 GHz and offers a 1 MHz video bandwidth and 1 MΩ video output impedance. The standard models also have the capacity to handle a maximum RF input power of up to +17 dBm. The RF interface of these detectors is a standard waveguide with an integrated Faraday isolator to improve the port VSWR. The output voltage polarity is negative and the connector type is a female SMA. Other configurations are offered as custom models.
-
product
Camera Based Beam Propagation Analyzer: M2
BeamSquared
The BeamSquared® system is a compact and fully automated tool for measuring the propagation characteristics of CW and pulsed laser systems from the UV to NIR to Telecom wavelengths. Users can also measure wavelengths above 1.8 microns, including CO2 and terahertz in manual mode (a bench set-up; without the automated optical train) with a Pyrocam IV or IIIHR. Our longer optical train and patented Ultracal™ Calibration makes BeamSquared the most accurate product on the market and is ISO 11146 compliant. Its operational robustness and reliability ensures continuous use applications in industry, science, research and development.
-
product
Electroplating Bath Analyzer
optek’s electroplating analyzers are inline devices designed to measure plating solution’s metal concentration in real time. These analyzers can be designed to accommodate virtually any concentration range. Operationally, the analyzer passes a white light beam through the plating solution to be monitored. Then, light absorbance is measured at two distinct wavelengths, and the difference in light absorbance between the two wavelengths is equated to a plating solution concentration.
-
product
Process EDXRF Spectrometer
NEX LS
Applied Rigaku Technologies, Inc
Featuring advanced third generation EDXRF technology, the Rigaku NEX LS represents the next evolution of scanning multi-element process coatings analyzers for web or coil applications. To deliver superior analytical performance and reliability, the EDXRF measuring head assembly was derived from the established Rigaku NEX Series high-resolution benchtop instrumentation. With this proven technology, the Rigaku NEX LS delivers rapid, non-destructive, multi-element analyses — for coat weight, coating thickness and/or composition — for elements from aluminum (Al) through uranium (U). The measuring head is mounted on a rigid beam and is equipped with a linear traversing mechanism positioned over a roller so that the head-to-surface distance is constant. Common applications include silicone release coaters, converters, denesting Si for vacuum-formed plastics, RoHS compliance, conversion coatings, metalized plastic, top coatings on metal coil and fire retardants on fabric.
-
product
Saybolt Color Analyzer
optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.
-
product
Optical Spectrum Analyzer Module
OSAPXIe
OSAPXIe enables new measurement capabilities in PXI for truly effective mixed-signal testing. Conduct all your DUT characterization from one platform and spend less time switching cables and patchcords between instruments.
-
product
PCIe 5.0 Protocol Analyzer
P5552A
The Keysight P5552A PCIe 5.0 Protocol Analyzer introduces a new form factor that is easily deployable in the lab bench environment to enable deep protocol analysis of a PCIe system with unparallel signal integrity. Locate protocol errors or validate device operations by viewing data from the physical layer all through the transactional layer with ease.
-
product
PCIe 5.0 Protocol Exerciser
P5551A
Keysight PCIe 5.0 Protocol Exerciser gives the flexibility in emulating either as a root complex or as an endpoint device when validating PCIe designs.
-
product
PCI Express, Analyzer Software Included, IEEE 488 GPIB Instrument Control Device for Windows - Onboard GBIP Analyzer
780935-01
The PCIe‑GPIB+ combines an IEEE 488 controller and an analyzer on one device for computers with PCIe slots. You can use this device to integrate an instrument into your system using GPIB as well as to troubleshoot and solve GPIB hardware and software problems. The PCIe‑GPIB+ achieves maximum IEEE 488.2 transfer rates. With an onboard bus master DMA controller, there is no microprocessor interruption in data transfers. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
product
PXIe Vector Network Analyzer Receiver
M9376A
Use the one port PXIe vector network analyzer receiver with Keysight's M9485A PXIe multiport vector network analyzer
-
product
CXA Signal Analyzer, Multi-touch, 9 kHz to 26.5 GHz
N9000B
Master the essentials in signal characterization with the leading low-cost tool in signal analysis Perform cost-effective stimulus response measurements with the optional built-in tracking generator Add crucial functionality with X-Series measurement applications Enhance theory with practical skills when used with a training kit in your RF & microwave education lab
-
product
PXIe Vector Network Analyzer, 300 kHz to 6.5 GHz
M9371A
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
product
PCIe 6.0 Protocol Analyzer
P5570A
Keysight PCIe 6.0 Protocol Analyzer redefines protocol debugging and validation through a new innovative CEM card form factor, bringing vast improvement in signal integrity and equalization with instant link-up to systems as well as devices under test
-
product
PXIe Multiport Vector Network Analyzer, 1 MHz to 9 GHz
M9485A
1 MHz to 9 GHzUp to 12-ports in one chassis, 24-ports in two chassis Various applications - full N-port cal, FOM, Pulse, time-domain, noise figure and gain compression analysis capability Improve accuracy, yield & margins with the best PXI VNA speed, dynamic range, trace noise and stability Improve throughput with fast cycle time: 5 msec at 201 points, 2-port calVarious configuration with standard test set and configurable test set
-
product
ARINC 818 Analyser
iWave’s ARINC 818 Video Protocol Analyzer (VPA) instantly verifies the ADVB Packets against ARINC818 Standards. ARINC818 VPA software efficiently captures, decodes the ADVB data, and displays the ADVB data, raw video data, and error status. It is an excellent troubleshooting tool that helps to quickly detect and rectify errors in the ARINC 818-2 applications, simultaneously ensuring compliance of the system with the ARINC 818-2 standards.
-
product
PXI Vector Signal Analyzer
Keysight's PXIe vector signal analyzers are ideal for design validation and manufacturing applications that require fast, high quality measurements where quality control, product conformance and test optimization are essential. With a small footprint, speed, scalability repeatability, and the flexibility to configure a solution with a shared processor, frame/chassis, display, and interface, PXIe vector signal analyzers provide the building blocks for your single or multi-channel modular test solution.
-
product
PXIe Vector Network Analyzer, 9 kHz to 6.5 GHz
M9801A
Full 2/4/6/ port VNA on a PXI module with flexible applications.
-
product
PXIe Vector Network Analyzer, 10 MHz To 44 GHz
M9837A
The M9837A PXI network analyzer (VNA) offers unrivaled performance for testing multiport, multisite, multi-DUT modulated signal measurement from 10 MHz to 44 GHz.
-
product
1mm Verification Kit
85059V
The Keysight 85059V is a 1.0 mm verification kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. This includes a set of standards with known characteristics, traceable to primary standards in the Keysight Technologies calibration lab. This verification kit is used to verify the measurement calibration and also to verify that the PNA/PNA-X based millimeter-wave system is operating within its specifications. The 85059V with 85059B 1 mm calibration kit are replacements for the 85059A 1 mm calibration/verification kit.
-
product
Optical Spectrum Analyzer - MATRIQ
1000 Series
The OSA 1000 Series provides grating-based spectral test and measurement. It is an excellent fit for the testing of optical sources, amplifiers, transceivers and passive optical components.The OSA is available in a range of wavelengths for different applications, so you pay only for the capabilities you need.