Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Seismic Transducers Calibration System
-
Calibration of the seismic sensors should be conducted in the low-frequency domain, which means, that the relative method used for calibration of the vibration transducers is not applicable since it does not guarantee the required accuracy level. The problem is that the reference accelerometers have uneven AFR characteristic in the low-frequency domain. Thus, calibration of seismic transducers requires implementation of a different approach.
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25F-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Xytronic Three-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-30, RX-31 and RX-33
-
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
Product
Calibration Kit
N611
-
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
Product
Open Standard Module (OSM)
ROM-2620
-
Advantech ROM-2620 OSM 1.1 Computer-on-Module is powered by NXP i.MX 8ULP SoC which includes up to 2 Arm Cortex-A35 cores in combination with one Cortex-M33 real timeprocessor and Vivante GC7000 nanoULTRA/GC328 graphics engine. It provides USB2.0, Fast Ethernet, MIPI-CSI, I2C, SPI, GPIO, PWM and MIPI DSI display for embedded applications
-
Product
UV Calibration
-
Determination of the angle dependent sensitivity of sensors in use with different UV lamps
-
Product
PD Calibrator
-
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.
-
Product
Multi-Element Standards
-
These multi-element standards consist of multi-layer thin film coatings, one on top of the other, upto a maximum of 6 elemental coatings. It is generally recommended to have coating thicknesses < 20 µg/cm2, so as to cause negligible notable matrix effects, in particular absorption of X-rays emitted in lower deposits by those covering them.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
-
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
Working Standard Shunts
CSW
-
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
Product
Standard 2.40 (68.00) - 6.20 (176.00) Battery Probe
BIP-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 188Test Center (mm): 4.78Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 60Recommended Travel (mm): 1.52Overall Length (mil): 396Overall Length (mm): 10.06
-
Product
Standard 0.88 (24.90) - 4.50 (128.00) Switch Probe
SSP-5C
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Spring Force Remark: Force at switch point: 2.36 (66)Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 150Full Travel (mm): 3.81Recommended Travel (mil): 100Recommended Travel (mm): 2.54Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,210Overall Length (mm): 30.73Switch Point (mil): 25Switch Point (mm): 0.64
-
Product
Standard Signal Loop-Powered
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation and 1: 1 transmission of 0/4 ... 20 mA current signals without additional auxiliary power. Also for use in hazardous areas. Particularly high reliability and certified functional safety up to SIL 3 / PLe.
-
Product
Nanolattice Standards for Analytical Instruments
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of Electron and Atomic Force Microscopes (AFM). Make the grade, with the highest quality pitch standard of its kind available.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I15-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Calibrators
-
Orbit Controls calibrators are suitable as signal sources for test benches or laboratories. They can be used as generators for calibrating and testing electronic measuring devices or assemblies, both by manufacturers and by companies that must perform periodic calibration tasks for quality certification.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39T15-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Calibration Software
-
Simplify your calibration through advanced software from Transmille. ProCal can automate your test equipment and increase productivity while reducing errors.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2TB-12
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4L
-
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Calibration and Measurement Services
-
A uniform light source which provides spatially uniform luminance and illuminance for flat-field correction and calibration imaging systems, calibration photometers and spectroradiometers.
-
Product
Calibration Services
-
A calibration industry leader since 1962, SIMCO provides trusted, high-quality instrument calibration services for thousands of organizations, including 15 of the top 20 global biomedical device manufacturers and 14 of the top 20 global aerospace and defense manufacturers.
-
Product
Automatic Calibration Function oH Meter
AH-151
-
The pH meter AH-151 with automatic calibration function performs pH measurement by automatically cleaning the electrode with cleaning solution and performing calibration with standard solution, making it possible to drastically reduce maintenance work. In addition, by spraying the calibration solution, the consumption of calibration solution has been reduced. The spray amount of the cleaning solution can also be adjusted according to the condition of contamination, which contributes to cost reductions. With periodic cleaning and calibration, stable and highly reliable pH measurements are possible.
-
Product
Standard Type Spring Probes
-
From for bare board to for ICT, we have variety of spring probes for PCB. In addition to variety of tip type and total length, we also have receptacles that match the best to spring probes. We can also attach lead wire to the receptacles.
-
Product
Standard Gain Horn Pyramidal Horn Antenna
-
Elva’s SGPH series of standard gain horn antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
Product
Ultra Low Noise, Rubidium Frequency Standard.
A10-M
-
Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.