Four-wire
-
Product
Panel-mount Type ORP Meter (Four-Wire Transmission)
HO-480
-
The HO-480 industrial ORP meter is an ORP converter for measuring the oxidation-reduction potential of all types of solvent.Being combined with a lead-free sensor, it makes measurements in a way that is kind to the environment.
-
Product
Field-installation Type pH Meter (Four-Wire Transmission)
HP-200
-
HP-200 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Field-installation Type Color Meter (Four-wire Transmission)
HU-200CL
-
HU-200CL connects flow through color detector Cl-20 and measures color and turbidity in the sample water. Suitable for monitoring purified water.
-
Product
Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission)
HR-480
-
HR-480 industrial residual chlorine meter takes sequential measurements of free residual chlorine, which is an indicator used in the inspection of the anti-bacterial properties of drinking water and swimming pools.The sensor(RS-1) combined with uses a galvanic method with no drive section, making it highly maintainable, and producing stable measurements over a long period.
-
Product
Field-installation Type Turbidity Meter (Four-Wire Transmission, For Wide Range)
HU-200TB-W
-
HU-200TB-W is a turbidity meter developed to continuously measure turbidity in processes with large turbidity changes, such as water intake and sedimentation tanks in water supply plants. It employs transmission 90-degree scattered light method and is ideal for monitoring changes in processes with large turbidity changes from low range (10 degrees) to high range (2000 degrees). An electric wiper cleaning can be installed as an option, and long-term stable measurement is possible by periodic cleaning.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, Pulse Proportional Control)
HP-480PL
-
HP-480PL industrial pH meter is a pH meter with a pulse proportional control function, which can drive a pulse pump directly.It connects pH sensor and measures pH and temperature in the sample water.As the HP-480PL has a high injection resolution per pulse, it can be used to control a pulse pump as part of a system for processing involving fine control of pH values, for example controlling the pH values of microscopic or small samples.
-
Product
Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)
HE-200H
-
HE-200H connects conductivity sensor (FES-125F,126F) and measures conductivity and temperature in the sample water. It can be used not only for measurement of electrical conductivity in aqueous solution, but also for concentration adjustment and rinse monitoring of CIP, etc., as well as for concentration monitor of process.
-
Product
Industrial pH Meter (Four-Wire Analyzer)
HP-200-K
-
One-touch calibration function Realizes gentle measurement by combination with lead-free ORP electrode
-
Product
Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)
HE-960CW
-
HE-960CW connects conductivity sensor (ESH /FS Series) and measures conductivity and temperature in the sample water. It is ideal for the conductivity control of the purified water, pasteurized water, and water for injection that are used in the production of pharmaceuticals.And we have developed a lineup of electric conductivity sensors that can be used in conjunction, from the conventional insertion type to the flow-through type with improved cleaning and sanitary properties.
-
Product
Panel-mount Type Resistivity Meter (Four-Wire Transmission)
HE-480R
-
HE-480R connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.The feature is the high-precision temperature compensation function.Its high-performance temperature compensation makes it ideal for sequential monitoring of ultra-pure water used in manufacturing processes in the semiconductor field, and many other fields, including the areas of electrical goods, foods and medicines.
-
Product
Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)
HE-200C
-
HE-200 connects conductivity sensor (ESH/FS Series) and measures conductivity and temperature in the sample water. It is suitable for monitoring pure water/boiler water drainage recovery control and inline measurement of pharmaceutical water conductivity according to USP<645> quality guidelines.
-
Product
Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Water flow beads)
HR-200
-
HR-200 is connected to a residual chlorine sensor (RA-20), which allows the free residual chlorine concentration to be measured with high accuracy. It is sutable for waterworks, pool water sterilization, and desalination systems. The measurement method is a three-pole polarographic method, which enables continuous monitoring of residual chlorine concentrations without using reagents. Stable measurement over a long period was realized by physical polishing cleaning using beads.
-
Product
Field-Installation Type ORP Meter (Four-Wire Transmission)
HO-200
-
HO-200 connects ORP sensor and measures ORP and temperature in the sample water. It is suitable for neutralization reaction treatment management of aeration tank, denitrification tank, etc.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, 4 point ararm, Time sharing Proportional Control)
HP-960FTP
-
HP-960FTP industrial pH meter is a high-end pH meter with a four-point alarm and a time sharing proportional control function.It connects pH sensor and measures pH and temperature in the sample water.It can also be linked with a cleaning device via an external input, extending its automatic operation time.Many types of electrodes are available to match the sample properties.
-
Product
Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission, polarography method type)
HR-480P
-
Panel-mount type transmitter HR-480P connects residual chlorine sensor (RA-20) and measures residual chlorine and temperature in the sample water. Suitable for monitoring swimming pool and anti-bacterial properties of drinking water.
-
Product
Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)
HD-200
-
HD-200 connects the DO (Dissolved Oxygen) sensor (DO-1100) and measures the DO in the sample water.The measurement method is membrane type polarography method. It is suitable for monitoring DO in wastewater treatment or aquarium for aquaculture.
-
Product
Panel-mount Type Resistivity Meter (Four-Wire Transmission, 2-channel)
HE-960RW
-
HE-960RW connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.This resistivity meter is ideal for such applications as the high-precision water monitoring employed at ultra-pure water plants used in semiconductor manufacturing.They utilize newly designed, high-precision, high-stability temperature measurement circuitry and a vastly improved temperature compensation function, an important element for measuring the resistivity of ultra-pure water.
-
Product
Four Wire Modem for SEL Mirrored-Bits
MBT 9600
-
Application specific features set the MBT9600 Four Modem apart from the conventional high speed modems. Its compact size and ease of installation make the MBT9600 an ideal, low cost alternative to conventional audio tone teleprotection systems.The circuitry is ideally suited for use over private networks such as conventional voice channels over analog microwave.
-
Product
Resistance Meter
MT8-4L
-
М-module МТ8-4Л is a mezzanine module designed to measure the resistance of resistive sensors using a four-wire measurement circuit in eight channels (eight-channel digitizer). М-module МТ8-4Л is installed on the carrier of mezzanines - module НМ-М and is connected to it via a local information highway. Up to four m-modules of various types can be installed on the NM-M module. The NM-M module, together with the m-modules installed on it, forms a VXI module of size C-1 and is used to create information measuring VXI systems.
-
Product
Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)
HC-200NH
-
HC-200NH is an ammonia nitrogen(NH4-N) meter using ion electrode method which is designed for aeration control in wastewater treatment.
-
Product
Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)
HE-480C
-
HE-480C connects conductivity sensor (ESH /FS Series) and measures conductivity and temperature in the sample water. This is a highly functional model, with high-performance temperature compensation, and is applicable to a wide range of tasks, from managing pure water for use with semiconductors, to managing the quality of boiler water.
-
Product
Kelvin Probe F83211S0022L650
1045235
-
The Kelvin Probe F83211S0022L650 (item number 1045235) is a Contact Probe for precise four-wire resistance measurements. The separate current and voltage paths in F83211S0022L650 support four-wire measurements in which lead and contact resistance have minimal influence on the result. The impedance specified for F83211S0022L650 is 50 Ω. The frequency range of F83211S0022L650 extends up to 1.2 GHz. The pitch of F83211S0022L650 is 5.5 mm / 217 mil. For F83211S0022L650, spring forces for the outer and inner contacts are 450 / 200 cN.
-
Product
Portable Three-Phase Energy Standard
PEWM-3C
-
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
Product
Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)
HR-200RT
-
HR-200RT is connected to a residual chlorine sensor (RA-30), which allows the free residual chlorine concentration to be measured with high accuracy. It is sutable for waterworks, pool water sterilization, and desalination systems. The measurement method is a three-pole polarographic method, which enables continuous monitoring of residual chlorine concentrations without using reagents.Stable measurement over a long period was realized by physical polishing cleaning using beads.
-
Product
Micro-Ohmmeters
-
The Micro-ohmmeter performs reliable low resistance measurements with test currents to 10A and resolution to 1. Uses a four-wire Kelvin bridge method, which eliminates test lead resistance for a measurement accuracy of 0.25%.
-
Product
Short Circuit Locator for Power Cables
A910
-
The A910 is a short circuit locator designed for fault location in power cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A910 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 5mohm (approximately 90 m of 300 sqmm cable) and less than 30 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
Product
Resistance Measurement
-
PROMET 100 / 200 / 600 high-accuracy, precision ohm meters deliver an adjustable test current up to 600 A which is independent of the supply voltage. They utilize the four-wire resistance measurement method, enabling them to meet extremely stringent accuracy requirements when determining resistance values in the micro-ohm range.State-of-the-art power electronics coupled with a robust design guarantee maximum reliability, even when used as portable devices in switching stations or industrial environments.The modern operating concept, an interface to the test systems of the ACTAS product line and an optional remote control unit make these micro-ohm meters flexible and versatile.
-
Product
Electrical Testing
-
Innovative Testing Solutions, Inc.
Our specialty is Direct Current automotive components. We perform product validation and design verification testing on both electrical components and systems. Also, we perform warranty investigation testing and failure analysis. We have voltage capabilities to 300 volts and current capabilities to 1000 amperes. Both two-wire and four-wire resistance measurements are supported from NanoOhms to GigaOhms.
-
Product
Independent 24-bit Sigma-Delta Type (One for Each Channel)
TR1
-
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
Product
Electronic Resistance Store
MPS2
-
The MPS2 module is a mezzanine module designed to form DC resistance in two channels with a four-wire measurement circuit. MPS2 is installed on the mezzanine carrier - the NMU module and is connected to it via a local information highway. Up to four mezzanines of various types can be installed on the NMU module. The NMU module together with the mezzanines installed on it forms a VXI module of the size C-1 and is used to create information measuring VXI systems.