Filter Results By:
Products
Applications
Manufacturers
-
product
Attenuators
The National RF line of attenuators are compact, affordable attenuators which are ideal for insertion between a direction finding antenna and a receiver/transceiver, to aid in the DF process. In addition, they may be used in the laboratory for a low-power, in-line attenuation purposes. The affordable price is achieved by utilizing standard 5% tolerance resistors and commercial hardware. For laboratory purposes, an attenuation versus frequency curve (to 500mMHz) is provided.
-
product
SA1500X, 1.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784256-01
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
Near Field Probes 30 MHz up to 6 GHz
XF1 set
The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
product
SA2500X, 2.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784257-01
The SA2500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
product
Optical Time Domain Reflectometry
OTDR600
The OTDR600 is an optical time domain reflectometry (OTDR) system for the measurement of attenuation and length of optical fibers. The OTDR600 is specifically designed for use in factories and laboratories where high linearity and productivity on factory spool lengths are crucial.
-
product
Transmittance Dust Measuring Devices
Maintaining a clear sightline even when dust concentrations are highTransmittance dust measuring devices transmit light through the entire duct. With this type of measurement, light attenuation indicates the concentration of dust inside the duct. These measuring devices are specially designed for medium to high dust concentrations and large duct diameters. Consequently, they are equally suited to emission and process monitoring as they are to hall monitoring applications.
-
product
High Impedance Active Probes
12C
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
product
Remote Dynamic Receiver
E1708A
The Keysight E1708A uses an optical fiber to transport the laser beam from a remote sensor assembly to the electronics. This improves measurement accuracy and repeatability by enabling you to mount heat-producing electronics away from the measurement area. The fiber optic cable also provides increased mounting design flexibility and easier access to the receiver attenuation and squelch adjustments.
-
product
NLFA Notch
The NLFA is a multiple element device allowing several useful field configurations. The three internal elements,one low frequency amplifier, two notch amplifier each with the cut off freq. of 50Hz (or 60Hz for a specific version) can be used as independent ones or combined together to increase the notch function. The effect of the cascade of two notches is the increasing of the signal attenuation for the notch frequency.
-
product
RF Test Enclosure Ideal For High-volume Repeatable Testing, ≥90 DB Isolation, 300 MHz - 18 GHz
dbGUARD
The dbGUARD provides up to 90 dB isolation from 300 MHz to 18 GHz. The IASG (Inverted Asymmetric Squarewave Gasket) design eliminates any leakage along the perimeter of the RF enclosure. This makes the dbGUARD conducive to testing all wireless technologies including 5G/LTE, Wi-Fi, Bluetooth, ZigBee, WiMAX, etc. The interior cavity is finished with a next-generation RF absorptive coating similar to what is found in stealth technology. This allows for positioning the DUT in the shielded box without affecting attenuation caused by reflections.
-
product
OTDR Tester
M-OTDR-502
Fuzhou Metricu Technology Co Ltd
Optical Time Domain Reflectometer Wavelength 1310 / 1550nm, max test range 150KM, Dynamic range 28 / 26dB, SOR standard data saving, create PDF/EXCEL format report, stable laser source, support CW/270/330/1000/2000Hz, Test fiber's length, loss, attenuation parameters and event map, locate connection point/fusion point, Automatic analysis of various linkers/fusion points, easy analyze of various events,Support saving curves number ≥30000pcs, loss test, detect the optical or optical components loss value, etc. Test IP camera, optical power meter, visual fault locator, RJ45 cable TDR test, cable tester, cable tracer, etc.
-
product
Attenuator
RFATT AXIe-0
*Dual channel AXIe attenuator with frequency range from 9 kHz to 10 GHz.*The module is designed to work as part of information measuring systems as a normalizer of radio frequency signals (power control: signal amplification or attenuation).
-
product
MS-M 26-Pin RF Cable Assembly, Female to Unterminated, 0.5m, RG178 Cable
40-979A-526-0.5m-FU
This 0.5m long MS-M RF 26-Pin cable assembly is constructed from RG178 Silver Plated Copper Clad Steel Wire with FEP insulation and an attenuation of 102dB/100m at 500MHz. Screwlocks are provided to secure the MS-M connector to the associated product.
-
product
Compact PCI Connector Board
cPCI-J2-SCSI
Ribbon cable is used between the rear IO and SCSI connector. The lengths are reasonably well matched. The cable is short. The design is intended for lower speed IO - 10 MHz and below. Above 10 Mhz there may be some attenuation.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
product
Digital Step Attenuators
Analog Devices provides a range of broadband IC digital attenuators that come in low cost, leadless surface mount packages. Our digital attenuator family offers excellent attenuation and includes off chip ac ground capacitors for near dc operation, making it ideal for an extensive number of RF and IF applications.
-
product
Optical Talk Set
TM4103N
TM4103N Optical Talk Set is an intelligent and efficient instrument that combines in one set the functions of both a digital optical phone and a stabilized light source. It is widely used in operations of installation, optical testing, maintenance and fiber attenuation value testing in data network, CATV and Telecommunication network. The TM4103 Talk Set can carry out full-duplex communication with high quality connection and not be affected by distance.
-
product
Accurate Measurements
SA500
The SA500 is a derivative of PFOs WS500 WorkStation. Its application focuses on spectral attenuation and is designed to produce accurate measurements quickly and with confidence
-
product
Coaxial Programmable Attenuators
Coaxial attenuators are constructed with passivated stainless steel for durable use in both engineering labs and production line environments. These coaxial attenuators are designed and manufactured for low VSWR, low insertion loss and high attenuation value accuracy. The standard offering covers the frequency range of DC to 110 GHz and includes various interface options from 2.4 mm to 1 mm connector types as well as both male and female interfaces. The power handling of standard models is 0.5 to 1 watt continuous wave (CW). Higher power handling levels and different attenuation values and connector types from those listed below can also be requested.
-
product
Digital Attenuator
Chengdu KeyLink Microwave Technology Co., Ltd.
The products can be used in microwave electronic components. Its attenuation values are determined by the input TTL/LVTTL control signal. So that the link can be achieved the desired gain or loss value.KeyLink's digital attenuators can be categorized as follows.
-
product
Digitally Controlled Programmable Attenuators
Broadband frequencies ranging from 30 MHz to 40 GHz. High attenuation levels up to 60 dB. PIN diode designs exhibit extremely fast attenuation step switching performance. Attenuation step size ranges from 0.03 dB to 1 dB. Programmable attenuator control bit sizes range from 5 to 10 bits. Models powered and command controlled via 15 pin female Micro-D socket or USB interface.
-
product
Optical Talk Sets
JW4103N
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW4103N Optical Talk Set is an intelligent and efficient instrument that combines in one set the functions of both a digital optical phone and a stabilized light source. It is widely used in operations of installation, optical testing, maintenance and fiber attenuation value testing in data network, CATV and Telecommunication network.
-
product
Programmable Step Attenuator, DC to 40 GHz, 0 to 11 dB, 1 dB steps
84904L
The Keysight 84904L programmable step attenuator offers coaxial measurements to 40 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life (greater than 5 million switching cycles per section) and an attenuation range of 0 to 11 dB in 1-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with with only 2.4 dB of loss at 40 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
product
Programmable Step Attenuator, DC to 40 GHz, 0 to 90 dB, 10 dB Steps
84906L
The Keysight 84906L programmable step attenuator offers coaxial measurements to 40 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life greater than 5 million switching cycles per section) and an attenuation range of 0 to 90 dB in 10-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with with only 2.4 dB of loss at 40 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
product
Fiber Loss Meter
Testing for loss (also called "insertion loss") requires measuring the optical power lost in a cable (including fiber attenuation, connector loss and splice loss) with a fiber optic light source and power meter (LSPM) or optical loss test set (OLTS.)
-
product
Optical Talk Set
JZ4103
Sichuan Jiuzhou Electronic Technology Co.,Ltd
JZ4103 is a new generation intelligent instrument ,that integrates the functions of optical phone, stabilized light source and optical power meter in one unit. It is widely used for construction ,testing maintenance and attenuation measurement of the optical fiber engineering ,it is full duplex communication and has high quality conversation .It is an excellent tool for optical network field work.
-
product
T3DSO Passive Probe, 350 MHz, 1X/10X, 1 MOhm/10 MOhm, 300V/600V
T3PP350
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
OTDR w/ Automatic Measurement Mode
TW3100
Techwin(China) Industry Co., Ltd
Features:Automatic Measurement Mode: Only by selecting the measurement wavelength, the measurement parameters are automatically set, and the trace data is automatically saved and automatically analyzed. Multi-wavelength Measurement Mode: In the parameter setting, the wavelength can be automatically switched into the multi-wavelength measurement mode. Under this mode, the analysis can be achieved on the attenuation state of the same fiber section under different wavelengths.