Filter Results By:
Products
Applications
Manufacturers
Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Calibration Standards
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
product
Electronic Calibration Module (ECal), 50 GHz, 2.4 Mm, 2-port
N4693D
The Keysight N4693D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4693D is a precision 2-port ECal module that supports 2.4 mm connectors up to 50 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4693D is included for securing your ECal module and accessories.
-
product
Calibration Services
A calibration industry leader since 1962, SIMCO provides trusted, high-quality instrument calibration services for thousands of organizations, including 15 of the top 20 global biomedical device manufacturers and 14 of the top 20 global aerospace and defense manufacturers.
-
product
6000 Series Analog I/O Modules
Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.
-
product
Miniature Concentric Ring Set
PRF-912B
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
product
Reference Thermometers
Reference thermometers (standard thermometers) are, due to their excellent stability and their geometrical adaptations, ideally suited for applications in industrial laboratories. They enable easy comparative calibration in baths, in tube furnaces and in dry-well calibrators. The advantage of reference thermometers is the wide temperature range, and with this, their flexible operation. Furthermore, with their low drift, a long service life is ensured.
-
product
Accelerometer Simulator
MTN/8302
The MTN/8302 is a battery-powered unit designed to simulate a constant current type accelerometer. It enables test and calibration of vibration monitoring equipment such as the Monitran MTN/6000 series.
-
product
Measurement Types and Kits
Keysight supplies a wide variety of optics for different calibration measurements. Choose individual optics or a pre-configured kit. Select desired measurement type from the chart or individual optics listed below.
-
product
Testing and Training Solutions
Teledyne LeCroy offers an broad array of testing services and educational training options. From advanced multi-day protocol training courses to device interoperability testing to calibration and testing service, Teledyne LeCroy offers valuable expertise, in-depth knowledge, leading edge testing solution, and top-notch engineers able help move your projects forward. Whether you need your team to come up to speed on the latest technology or you just need more hands getting your product tested and ready for market, we can help.
-
product
Thermometer Hygrometer Barometer
H7531-2
Sensor H7531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
NIST Calibration for D410-A
D410-A-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
USB Axis Module
E1735A
The E1735A USB Axis Module is the electronic interface for the 5519A/B laser head used in the Keysight 5530 Laser Calibration System. It also provides the interface for the 10888A remote control unit (optional) and the A-quad-B encoder input (optional).
-
product
Turning Mirror
10772A
The Keysight 10772A Turning Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror is used in the 5530 Laser Calibration System for applications such as machine tool calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10772A.
-
product
Calibration
RF Test Equipment
We calibrate following types of RF test equipment:EMF test systems (frequency selective)EMF test systems (broadband)Field strength transfer standards (e.g. RefRad)Line Impedance Stabilisation Network (LISN)Cable, attenuator, couplerAntennaField Probe
-
product
Dipole Antenna
AD-100
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
product
Image Analysis & Stage Micrometers
The APPLIED IMAGE series of Image Analysis and Stage micrometers are ideally suited for calibrating optical, imaging, video, and reticle-based measurement systems. Designed for ease of use and manufactured for durability, the SM Series has both English and Metric scales in one or two axis configurations. Both types of micrometers come with NIST traceable calibration standards and are available on multiples substrates to perfectly fit your needs. The experience APPLIED IMAGE has in manufacturing precision imaged optical components makes us the trusted source for standards for magnification system microscopy and vision applications. Should you need to alter feature patterns, size, or substrate, fill out our Custom Optical Components and Standards form to start the conversation.
-
product
Radon Professional Monitoring
Our dedicated range of products and accessories has been especially designed to fit these needs and to provide accuracy in the following application fields: Short and long-term monitoring of radon concentration indoor and outdoor, water and soil gas analysis Radon surveillance and mitigation at workplaces (according to valid radiation protection regulations) Geological survey, e.g. vulcano watching, earthquake surveillanceAlphaGUARD products reputation is worldwide recognized, as a reference device for calibration for active and passive radon detectors.
-
product
Calibrated Solar Reference Cell
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
product
ESU Analyzer
ESU-2050
The BC Biomedical ESU-2050 ESU Analyzer is the first instrument of its kind on the market. Designed through extensive collaboration with several of the world's leading electrosurgery generator manufacturers. It is the only ESU Analyzer on today's market with a 1% reading level of accuracy. Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer.
-
product
Average Power Sensors
E9300
Operates with the EPM, EPM-P and P-series power meters Wide dynamic range sensors (80 dB maximum)Accurate average power measurements on all modulation formats Wide frequency coverage from 9 kHz to 18 GHz (special option to 24 GHz)Calibration factors stored in EEPROM Fast measurement speed over the GPIB (up to 400 readings per second with the E4416A)
-
product
Light Meter
2330 LX
Standard Electric Works Co., Ltd
● Wide range for measurements up 40000 lux and 4000 fc.● 0.01 lux and 0.001 fc resolution for accurate low light level measurements.● Light sensor cover is included for preserving sensor life.● Auto off function.● Data hold function.● Low battery indication.● Over range indication.● Auto-ranged.● Manual-ranged.● Calibration mode is provided.● 9V battery system.● Selection key for lux and fc.● The spectral sensitivity close to CIE photopic curve.● Ideal tool for workplace, clean-room and computer room light testing.● Video, photographic, office, classroom, and architectural uses.
-
product
PAT Calibration Checkboxes
Seaward's special PAT calibration checkboxes are designed to provide a fast and simple means of confirming that test readings remain effective during those working periods between formal re-calibration.
-
product
Emissions Dynamometers
MD-250-M
Mustang has developed a low-cost, simple to use, easy-to-install heavy duty chassis dynamometer that can be used to simulate real-world driving conditions in a safe, controlled environment and can also be used for “static” diesel smog testing for regulatory purposes. This model is used in Diesel Smog Programs in Nevada and Colorado when combined with an approved opacity meter. The MD-250-M is a compact dynamometer with industry proven design features including 10.7-inch rollers, heavy duty spherical pillow-block ball bearings, welded structural steel frame, 7.5 hp calibration motor, and an industry standard air-cooled, Eddy Current Power Absorption Unit (PAU) for road-load simulation. The MD-250-M is available in both right and left hand configurations to accommodate different facility designs.
-
product
Calibration Kit
S2611
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.
-
product
Process Ozone Monitor
Model 465H
Teledyne Advanced Pollution Instrumentation
The Model 465H is a microprocessor based high concentration ozone monitor for measuring ozone in process gas streams in water treatment, food processing, and research applications. The 465H has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465H is available in a NEMA 4X wall mount enclosure.
-
product
pH 6+ Handheld pH Meters
High +/-0.01 pH accuracy at an economical price*Convenient, compact design*Up to five-point push-button calibration with autobuffer recognition*Displays pH or mV and temperature with the press of a button
-
product
Electronic Calibration Module (ECal), 67 GHz, 1.85 Mm, 2-Port
N4694D
The Keysight N4694D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4694D is a precision 2-port ECal module that supports 1.85 mm connectors up to 67 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4694D is included for securing your ECal module and accessories.
-
product
Calibration Kit
WR-10
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
product
Calibration Software
EasyCal is a complete software package with features covering all aspects of calibration work and management. It is designed to reduce workload, improve efficiency, and provide the essential platform for companies looking to create and sustain an effective calibration program. The comprehensive features simplify the administration process from reminder reports through to despatch. With a familiar and intuitive user interface all operators can quickly learn and navigate through the applications. This allows fast, straightforward implementation and integration of this calibration management software.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.