Cross Correlator
-
product
Cross-Correlator Pulse Profiling Systems
Rincon
The third order cross-correlator is ideal for looking at the full range of output from amplified femtosecond laser systems. High temporal resolution over a long (close to 1 ns) window shows pulse features that are usually missed, giving the user a detailed and complete picture of the quality and stability of the output pulse parameters of their femtosecond lasersystem.
-
product
Single Shot Third-order Cross- Correlator
Rincon SS
Specifically developed for measuring a wide array of output parameters from ultrafast laser systems including: contrast ratio of laser pulses, determining pulse pedestal, pre- and post-pulses, and amplified spontaneous emission in femtosecond systems.
-
product
Auto-Correlator/Cross-Correlator
FR-103WS
The FR-103WS is a dispersion-free Autocorrelator/Crosscorrelator for monitoring the temporal width of ultrashort optical pulses. While providing excellent sensitivity and resolution, the FR-103WS is ideally suited for the measurement of long pulsewidths (up to 200ps).
-
product
Phase Noise Analyzer
NXA-6
This new NXA-6 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 6 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
product
Phase Noise Analyzers
The phase noise analyzer portfolio from Rohde & Schwarz offers an affordable, mid-range solution with high sensitivity and fast measurements as well as high-end ultra-high-sensitivity solutions with advanced measurements modes. Ideal for phase noise analysis and VCO tests, the industry-leading solutions enable two-path phase noise analysis with real-time cross correlation and fast VCO characterization with built-in low-noise DC sources. Additionally, high-end signal and spectrum analysis can be added into a single box.
-
product
Phase Noise Analyzer
NXA-50
This new NXA-50 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 50 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
product
Rapid Scanning Auto-Correlator / Cross-Correlator
FR-103XL
The FR-103XL is a dispersion-free Autocorrelator/CrossCorrelator for monitoring the temporal width of ultrashort optical pulses. Offering unsurpassed sensitivity and resolution, it is compact and easy to operate. The FR-103XL is ideally suited for the measurement weak signals in optical telecommunications, as well as pulses from other mode-locked lasers such as Ti-Sapphire.
-
product
STEREO PERFORMANCE METER
SPM-1
The SPM-1 measures the stereo content present in any left and right audio program material. It measures 0-50 dB separation on live program material by cross correlating the right and left base-band audio information.
-
product
Phase Noise Analyzer
NXA-26
This new NXA-26 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 26.5 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range. The NXA-26 combines over 25 years of Phase Noise Measurement Technology with an easy to navigate user interface. System operation requires minimal training that will have you making measurements in minutes.
-
product
Correlation Analysis
EDM Modal Correlation Analysis allows the user to correlate two modal models; EMA and/or FEA models. Comparing the experimental data with that acquired through finite element analysis helps in validating the test results. Users can import the geometry model and mode shape data from FEA or EMA software.
-
product
Cross Browser Testing
Today’s proliferation of devices and browsers means your user or customer base is highly fragmented and no assumptions can be made about the platforms being used. Through cross browser testing, also known as compatibility testing, Digivante helps you to uncover issues that might block conversion before your users do.
-
product
Crossing Control Bypass Switch
XCBS-DL
The XCBS-DL is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the track connection harness to the designated track connection terminals. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. When in the "bypass" position, a Dummy Track Load is connected to the track wire connections in parallel with the rails and the crossing approaches are shorted, preventing unnecessary activation when track equipment is working in the crossing approach circuit. The opening of one track lead may be desired to prevent unnecessary activation with intermittent shunting on the crossing approaches close to the crossing.
-
product
Cross Sections and Metallography
Rocky Mountain Laboratories, Inc.
Cross sections are prepared by mounting samples in epoxy and then grinding and polishing the mount for imaging in the optical microscope or Scanning Electron Microscopy (SEM). Valuable information from cross sectioning can include: film thicknesses, inclusions, corrosion thickness, dimensional verification, and subsurface defects. Metallographic cross sections are typically etched to reveal the microstructure. Microstructural analysis can provide information about heat treatment history, corrosion susceptibility, as well as undesirable microconstituents.
-
product
Gas Filter Correlation CO Analyzer
Model N300
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Cross Hole Energizer P/S
CHE
Specially designed for small-scale cross-hole surveys, this compact hammer can be used to generate both P and S waves.The hammer can be downloaded using the steel cable and clamped to the requested depth by a pneumatic clamping system manually controlled by a lever from the surface; simply pushing up the steel cable to execute the first shot, the trigger installed on the energizer will start the acquisition for the “P/S”. After that you will have to drop the mass to make the acquisition with inverse polarity.
-
product
Gas Filter Correlation CO Analyzer
Model T300U
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
High-Speed Digital Image Correlation System
Q-450
The 3D High-Speed Image Correlation System Q-450 allows the full-field, non-contact and three-dimensional dynamic measurement of shape, displacements and strains on components and structures made from almost any material. Based on the digital image correlation technique, the Q-450 system is designed for full-field vibration analysis and high speed transient events. This makes it ideal for ballistics testing, fracture mechanics, shock excitations, the Hopkinson Bar test, or Impact Testing.
-
product
Cross Cut Adhesion Tester
1540
The Elcometer 1540 Cross Cut Adhesion Tester is a simple instrument for quickly determining the coating adhesion of a large variety of paints up to 50µm (2 mils) thickness.
-
product
Crossing Control Bypass Switch
XCBS
The XCBS is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the crossing control circuits to the designated terminals on the XCBS. The rotating "knife switch" on the left side of the XCBS allows the crossing warning system to be controlled for manual test purposes. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. The non-removable bypass key adds an additional level of security for the Bypass function. Optional hookup can be made to the auxiallary terminals to include the activation of a strobe or event recorder input when the XCBS is placed in the "bypass" position.
-
product
Digital Image Correlation (DIC) Measurement System
EduDIC
EduDIC is a complete Digital Image Correlation (DIC) measurement system, designed as a simple and convenient educational training tool for academic courses in experimental solid mechanics. This easy-to-use system allows academic instructors to effectively present the optical measurement technique of DIC for materials testing to the engineers and scientists of tomorrow.
-
product
Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300M
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
36x36 Cross Bar Switch (CBS)
AMC241
The AMC241 is an AMC form factor with a 36x36 CBS which allows any of the 20 lanes from the backplane to be routed to the front. Since the CBS is agnostic to the protocol, any protocol such as PCIe, SRIO, 40GbE, 10GbE, GbE, Aurora, etc. could be routed between the backplane and the front panel.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
product
Correlative Microscopy
Our modular software platforms enable you to acquire, process and analyze images in multiple dimensions and over various timepoints
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model T360M
Teledyne Advanced Pollution Instrumentation
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.
-
product
Cross Platform Data Collection and Analysis Software
PARKvue
SPARKvue makes data collection, analysis, and sharing quick and easy on every platform. Compatible with all of PASCO’s wireless and PASPORT sensors, students can quickly set up their lab, or use a built-in Quick Start Lab and begin collecting data immediately. SPARKvue is for all sciences and grade levels. However, if you’re an advanced user looking for more capabilities such as video analysis, advanced statistics and calculations, and greater customization of data displays on a PC or Mac®, then check out our PASCO Capstone™ software.
-
product
Cross Development Tools
68HC12 and HCS12
Cosmic's toolchain for the 68HC12/HCS12 family is part of a complete and uniform product line incorporating over 20 years of innovative design and development. Cosmic's familiar and easy to use software interface is available for all Freescale microcontrollers to simplify the migration between targets. All Cosmic products include one year of technical support and updates.
-
product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.