Voltage Drop
electrical energy given up flowing through a circuit.
-
product
Cycle Voltage Drop (Rise) Simulator
STT-CSS-20P1
Beijing KeHuan Century EMC Technology Co,.LTD
*Using 2 The regulator, and the rated voltage adjustable automatic voltage regulator, power fluctuations avoid adversely affecting the test results. Simulate the test under 110V power supply. It can simulate the fluctuation of the power grid under extreme conditions (such as high or low power supply voltage in remote areas).
-
product
4 Digit Field Indicator
CFIA-40 4
1. Using LED to display, and able to be used in dark environment2. No external power needed3. Able to display measured value like pressure , temperature and depth etc4. Display solution 1/99995. Isolated alarm open drain output6. Voltage drop will below 4 volt
-
product
SiC Diodes
ST’s silicon carbide diodes range from 600 to 1200 V – as single and dual diodes – and feature unbeatable reverse recovery characteristics and improved VF. Available in a wide variety of packages, from D²PAK to TO-247 and the insulated TO-220AB/AC, they offer great flexibility to designers looking for efficiency, robustness and fast time-to-market. ST’s SiC Schottky diodes show a significant power-loss reduction and are commonly used in hard-switching applications such as high-end-server and telecom power supplies, while also intended for solar inverters, motor drives and uninterruptible power supplies (UPS). ST’s automotive-grade 650 and 1200 V SiC diodes – AEC-Q101-qualified and PPAP capable – feature the lowest forward voltage drop (VF) on the market, for optimal efficiency in electric vehicle (EV) applications.
-
product
Wide-range Programmable DC Power Supply
IT6900A Series
IT6900A series wide range programmable power supply have built-in standard RS232, USB, GPIB, RS485 and analog interface (RS485 and analog interface are just for IT6900B), support SCPI protocol, facilitate remote control, industrial PLC control and the formation of intelligent test platform. Remote compensation terminals avoid the problem of inaccurate testing caused by voltage drop on the wire.Low ripple, low noise and built-in digital voltmeter make IT6900A easy to do external measurement.IT6900A can be widely applied in DC-DC power supply module, battery charging and sensors and other test areas.
-
product
Primary & Secondary Current Injection Testing Sets
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.
-
product
DC Filter Inductors
Osborne DC filter inductors (aka filter chokes) are commonly used in AC to DC conversion circuits to present an inductive voltage drop to the AC component of rectified current. This inductive voltage drop acts as a filter. Osborne designs filter inductors to components to function effectively (without saturation) in the presence of the DC current. Osborne will work with you to mitigate the impact of ripple frequency in conversion circuits. Every Osborne DC filter choke is designed for high performance with special consideration given to your circuit´s power supply frequency and conversion configuration.
-
product
Soil Moisture Sensor
Modbus RS485
This is a contact-less capacitive soil moisture sensor, a continuation of my I2C soil moisture sensor. This particular version of the sensor is suited for more professional installations where long cable runs is a requirement. It adds a local voltage regulator to mitigate the voltage drop and RS485 transceiver to accommodate long wires, also reverse polarity and an additional ESD protection level is added.
-
product
Voltage Sag Generator
SKS-1132GTB
Shanghai Sanki Electronic Industries Co., Ltd.
The cycle drop simulator is used to reproduce the voltage fluctuation phenomenon of commercial power supplies. Simulate the grid voltage drop and short-term interruption caused by the accident or the sudden change of the large load in the low-voltage power grid, or the grid voltage change caused by the continuous change of the load. Used to evaluate the performance of the equipment under these voltage changes.
-
product
Mobile Comm DC Source w/ Battery Emulation, DVM
66321D
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66321D mobile communications dc source provides fast transient response, exceptional sourcing, output resistance programming, and precision measurement. This product is specially designed for testing next generation digital wireless communications products. The 66321D mobile communications dc source offers a new capability that simulates the internal resistance of a battery or battery pack. Additionally, these high performance models offer improved transient response and stable output operation with either short or long load leads. The 66321D dc source provides all of the capabilities of the 66321B with the addition of a built-in digital voltmeter.
-
product
Scanning Vibrating Electrode Technique
VS-SVET
The Scanning Vibrating Electrode Technique uses a single wire to measures voltage drop in solution. This voltage drop is a result of local current at the surface of a sample. Measuring this voltage in solution images the current at the sample surface. Current can be naturally occurring from a corrosion or biological process, or the current can be externally controlled using a galvanostat.
-
product
SparkFun Current Sensor Breakout
INA169
The INA169 is a “high-side current monitor,” which means that you place a resistor (a “shunt resistor”) on the positive power rail and the INA169 measures the voltage drop across that resistor. The INA169 outputs a small current based on the measured voltage drop. If you place a resistor from the output of the INA169 to ground, you can measure the voltage at the output.
-
product
SureTest® Circuit Analyzer
61-164
*Measures voltage drop under load**Hot and neutral conductor impedances*Estimates Load on Line (ELL) up to 15A*Tests GFCIs and EPDs for proper operation*Super-bright OLED display*High accuracies*True RMS*Line and peak voltage*Identifies proper wiring in 3-wire receptacles*Identifies false (bootleg) grounds*Tests without disturbing sensitive loads*Verifies isolated grounds (with 61-176 adapter)*2-year warranty*12A, 15A, 20A load tests
-
product
MICRO OHM-METER
UONT100A
International Biological Laboratories
This Test Set is capable to measure low resistance like switch contacts, breaker contacts, busbar splices, joints, fuses, low inductive windings etc. by circulating high value of D.C. through the contact/junction and measuring D.C voltage drop (4 terminal method) which, sent to instrument amplifiers , thereby being displayed on resistance meter.
-
product
Dual Mobile Comm DC Source w/ Battery Emulation, DVM
66319D
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.
-
product
Digital Multimeters
ST-3501
Standard Electric Works Co., Ltd
● Display: 3½ digit liquid crystal display (LCD) with max. reading of 1999.● Polarity: Automatic, (-) negative polarity indication.● Zero Adjustment: Automatic.● Over Range Indication: Highest digit of (1) or (-1) is displayed.● Low Battery Indication: The (BAT) is displayed when the battery voltage drops below the operating voltage.● Measurement Rate: 3 measurements per second, nominal.● Operating Temperature: 0°C to ±50°C, 0-70% RH.● Storage Temperature: -20°C to +60°C, 0-80% RH, with battery removed.● Accuracy: Accuracy specifications at 23±5°C, less than 75% RH.● Power: Single, 006P 9 volt battery● Dimensions: 128(L)×72(W)×33(D)mm.● Weight: Approx .200g
-
product
Electrical Safety Test Equipment
Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.
-
product
Capacitive H.V. Detectors (Contact)
213 HVD~226 HVD
Standard Electric Works Co., Ltd
● Excellent shock resistance.● Rugged nylon moulding.● Auto on (when voltage detected).● Excellent drop resistance.● Good vibration resistance.● Loud sound alarm indication.● Built-in proving and self-test circuit.● High bright color-coded LEDS.● Works from standard 9V battery.● Interchangeable contact electrode.● Use in all whether conditions.● Compatible with all link sticks.● Lightweight, robust & compact.● Models available from 11kV to 132kV.● Suitable for indoor and outdoor use.● Self(auto on) or manual arming.● Easy access to batteries.● Customized threshold on demand.● Auto off (if no voltage detected).● Waterproof design, protection class : IP65.
-
product
Battery Electrical System Analyser
We invented the “Resistance method” which uses a series of shorting pulse to measure the voltage drop in order to calculate the plate’s internal resistance. Unlike other patented “Conductance method” which generates an AC pulse across the battery terminal to measure impedance.
-
product
Digital I/O Board, 32 Isolated I/O Channels, 24V +special EEPROM & TTL IO Port
APCI-1500-PULS
PCI interface to the 32-bit data bus Connector compatible to PA 1500 Connector and software compatible to CPCI-1500 16 isolated input channels, 24 V, including 14 interruptible 3 software-programmable counters/ timers 16 isolated output channels, 10 to 36 V, output current 500 mA Timer-programmable watchdog for the reset of the outputs"-PULS" version has a special EEPROM and a TTL IO port added at end of cardDiagnostic report through status register in case of short-circuit, overtemperature, voltage drop or watchdog Interrupt triggered through watchdog, timer, error One ground line for all inputs and one ground line for all outputs
-
product
Digital Multimeters
ST-3201
Standard Electric Works Co., Ltd
● Display : 3½ digit liquid crystal display (LCD) with max. reading of 1999.● Polarity : Automatic, (-) negative polarity indication.● Zero Adjustment : Automatic.● Over Range Indication : Highest digit of (1) or (-1) is displayed. ● Low Battery Indication : The (BAT) is displayed when the battery voltage drops below the operating voltage.● Measurement Rate : 3 measurements per second, nominal.● Operating Temperature : 0ºC ~ 50ºC, 70% R. H.● Storage Temperature : -20ºC ~ 60ºC, 80% R. H.● Accuracy : Accuracy specifications at 23 ± 5ºC, less than 75% R. H.● Power : Single, 006P 9 volt battery● Dimensions : 128(L) × 72(W) × 33(D) mm.● Weight : Approx. 183g
-
product
Loop-Powered Digital Panel Meter
88-PRO
The 88-PRO Process Meter may be connected directly to a 4-20 mA, 10-50 mA or 1-5 mA current loop, with no need for additional power to the meter. This is because the meter is powered directly by the current loop, developing a maximum voltage drop of 2.5 V.
-
product
Thermocouple Thermometers
Polarity: Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 270g including batteries.
-
product
PCIe Digital I/O Board, 16 Optically Isolated I/O Channels, 24V
APCIE-1516
8 digital inputs, 24 V, isolated15 interruptible inputs8 digital outputs, 24 V, isolated, 10 to 36 V, 500 mA/channelOptical isolation 1000 VWatchdog for resetting the outputs to "0" (when Power-On)Protection against fast transients, overvoltage, electrostatic discharge and high-frequency EMIInputs: voltage reversal, input filtersOutputs protected against short circuitOvertemperature and overvoltage protectionDiagnostic report in case of short circuits, overtemperature, voltage drop ...24 V power outputs with protection diodesShutdown logic when the external supply voltage drops below 5 V
-
product
Dual Mobile Communications DC Source
66309B
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.
-
product
Digital I/O Board, 32 Isolated I/O Channels, 24V, LACQUERED
APCI-1500-LAC
PCI interface to the 32-bit data busConnector compatible to PA 1500Connector and software compatible to CPCI-150016 isolated input channels, 24 V, including 14 interruptible3 software-programmable counters/ timers16 isolated output channels, 10 to 36 V, output current 500 mATimer-programmable watchdog for the reset of the outputs to ??Diagnostic report through status register in case of short-circuit, overtemperature, voltage drop or watchdogInterrupt triggered through watchdog, timer, errorOne ground line for all inputs and one ground line for all outputs
-
product
Infrared Thermometer
Display: 3 1/2 digit liquid crystal display (LCD) with amaximum reading of 1999.Polarity: Automatic, positive implied, negative polarityindication.Low battery indication: the " " is displayed when thebattery voltage drops below the operating level.Operating environment: 0°C to 50°C at<75% relativehumidity.Storage temperature: -20°C to 60°C, 0 to 80% R.H.withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% relativehumidity.Auto power off : 10 secondsDimensions: 148mm(H) x 105mm(W) x 42mm(D).
-
product
Current Measurement Board
MS 1814
*Maximum DC Voltage Rating: 15V to 75V*Maximum DC Current: 5A*Output Voltage per 1A: 1V*Maximum AC Current: 5A*Operating Temperature: 0°C to 55°C*Storage Temperature: -20°C to +65°C*90% Relative Humidity (Non-condensing)*No. of DC Current Channels: 9*No. of AC Current Channels: 4nos*Maximum AC Voltage Rating: 230VAC*Channel Selection: Through 16 CH Analog MUX*Measurement Error Over Full Temperature Range: 5%*Type of Output: Proportional voltages*Maximum Voltage Drop across Series Resistor Full Scale Measurement: 0.05VDC
-
product
PCIe Digital I/O Board, 64 Optically Isolated I/O Channels, 5V-HS
APCIE-1564-5V-HS
32 digital inputs, 5 V, isolated16 interruptible inputs32 digital outputs, 5 V, isolated, 10 to 36 V, 500 mA/channelOptical isolation 1000 VWatchdog for resetting the outputs to "0" (when Power-On)Protection against fast transients, overvoltage, electrostatic discharge and high-frequency EMIInputs: voltage reversal, input filtersOutputs protected against short circuitOvertemperature and overvoltage protectionDiagnostic report in case of short circuits, overtemperature, voltage drop ...24 V power outputs with protection diodesShutdown logic when the external supply voltage drops below 5 V
-
product
RTD Thermometers
Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 255g including batteries.
-
product
PXI 2 Pole 18 way Mux with 2 Pole 18 way sen
40-658-002
This PXI multiplexer combines a 2-pole 18-way power distribution MUX with a second lower power 2-pole 18-way MUX in one convenient single slot PXI module.The module is ideal for power distribution where power and sense signals are required to be connected to an array of devices under test. This multiplexer is also convenient for making 4 wire low resistance measurements by supplying the resistor under test with high current through the power MUX and sensing the voltage drop through the sense MUX.