Scattering
a propagating wave or moving particle's linear trajectory, interrupted by non-uniformity in the medium they move through.
-
Product
Sapphire Defect Laser Probe and Glasses
LP-100
-
Easy to use and portable■ low price with long lifetime■ can be used to detect many defects, like micro crack, bubbles, impurity, crystal subgrain■ When the laser go though the crystal, if it is monocrystal the light should be scattering, in macro it should be white.
-
Product
Laboratory And Analysis Systems
-
High performance UV-VIS-IR spectrophotometer with superb optical performance for the determination of spectral absorption coefficient and spectral effective scattering coefficients
-
Product
Smaet LDV III
-
A Laser Doppler Velocimeter (LDV) measures fluid velocity by utilizing coherence of laser light. It detects the Doppler shift frequency of the scattering light of particles in the fluid and calculates the velocity of the particles (fluid). With a LDV system, non-intrusive measurements without disturbing the measuring object, liquid or gas flow, are achieved. No calibration is necessary and reverse flow measurements at a high resolution is also possible. The LDV system provides the absolute value of the flow velocity with accuracy.
-
Product
EMORAL LiDARESA Mobile Raman
-
The EMORAL LIDAR observations at the PolWET site in Rzecin, Poland, on 10 June 2019. The scattering ratio (top), quasi-particle depolarization ratio (middle), and backscatter colour ratio (bottom) derived at 532 nm with 30 m spatial and 30 s temporal resolutions
-
Product
Turbidity Sensor
TF56-N
-
The TF56-N sensor is an inline real-time device designed to measure light absorbance at 11° caused by interaction with process turbidity. As an NIR light beam is passed through a dynamic process stream, the sensor simultaneously measures the amount of light scattered at 11° and the remaining amount of un-scattered light at 0°.
-
Product
UltraScan VIS Spectrophotometer
Spectrometer
Hunter Associates Laboratory, Inc.
The UltraScan VIS easily measures both reflected and transmitted color as well as transmission haze and meets CIE, ASTM and USP guidelines for accurate color measurement. UltraScan VIS uses diffuse/8° geometry with automated specular component inclusion/exclusion. For transmission measurement, the use of a robust CIE-conforming sphere instrument (TTRAN Total Transmission mode) effectively negates the effects of minor scattering typically found in transparent samples.
-
Product
Turbidity Meter
TF16-N
-
The TF16-N is a high precision turbidity meter for installation into pipelines measuring scattered and unscattered light at two independent angles in various liquid process streams. The ratio of scattered to un-scattered light can then be correlated.
-
Product
Small-Angle X-Ray Scattering (SAXS) Products
-
Small-Angle X-Ray Scattering (SAXS) Products from Rigaku
-
Product
Antennas
-
Our broad portfolio of antennas includes products designed for cellular, broadcast, navigation, RFID, IoT, DAS, mmWave, and more. Our antennas are available in standard and custom designs and engineered for use in cars, heavy-transport vehicles including rail, and a wide variety of personal electronics, including mobile device and wearable technology. Our antennas offer high-quality transmission for a wide variety of frequencies including, but not limited to Bluetooth, WLAN, and ZigBee. We manufacture our antennas in facilities worldwide, which include testing capabilities in near and far field patterns, scattering parameters, SAR, vibration, humidity, temperature shock, salt fog, throughput, and acoustic. We also manufacture antenna assemblies.
-
Product
Physical Contact Connectors
-
Amphenol Fiber Systems International
Physical Contact (PC) connections are characterized by the physical mating of two optical fibers. Precision ceramic ferrules are typically utilized for PC connections. A PC connection is accomplished by terminating the optical fiber into a precision ceramic ferrule. Epoxy is used to affix the fiber into the ferrule. The tip of the ceramic ferrule is polished in a precise manner to ensure that light enters and exits at a known trajectory with little scattering or optical loss. Polishing the terminated ceramic ferrule is a critical process in Physical Contact fiber optic connectors.
-
Product
Vector Network Analyzer
SNA5000A
-
The SIGLENT SNA5000A series of Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2 and 4 port models available. Designed to give you instant insight into scattering, differential, and time-domain measurements. They are effective instrumentation for determining the Q-factor, bandwidth, and insertion loss filters and feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. There are five sweep types: Linear-Frequency, Log-Frequency, Power-Sweep, CW-Time, and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response, and Enhanced Response for increased flexibility in R&D and manufacturing applications.
-
Product
Optical VSF Sensors
-
The optical Volume Scattering Function(VSF) is an ‘inherent optical property’ of water that is used by optical oceanographers to predict light propagation, image degradation, remote sensed ocean color, biological environment etc. in water.
-
Product
UV Man Spectrometer
-
UV Raman (with laser wavelengths below 400nm) can be used to probe specific sample properties, and benefit from experiment properties different from typical visible Raman measurements – for example, greatly increased Raman scattering efficiency, modified laser penetration within the sample, and resonance coupling to different chemical moeities. However, UV analyses come with a number of technical challenges, that require considered instrument design to allow UV Raman to be a truly useful tool for the researcher.
-
Product
Water Treatment Plant Analyzer
Aqualog
-
Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.
-
Product
Fix, Speed Up and Maintain Your PC
Fix-It Utilities 15 Professional
-
System DashboardGet an instant overview of important system information, disk and memory space, battery life and processes running on your PC in one easy place.Look at system information on: operating system, default web browser, IP address, power settings and battery life.Know how much disk and memory space you are using, how much is free and your disk fragmentation level.See what processes and programs are running at startup and during active use.Data RecoveryEasily recover deleted files and data from your hard drives, USB drives, flash drives and memory cards.Disk Space SaverRan out of space on your drive? Are your files scattered everywhere? No Problem! Disk Space Saver scans and identifies where your large, duplicate, junk and Internet files are located.Get a visual display of your disk space usage that lists your biggest and duplicate files.Clear browser and download history, surfing activity cache and Internet cookies.Identify and remove unnecessary system clutter and junk files.Windows 8 CompatibilitySystem Suite is now fully compatibility with Microsoft Windows 8. Run System Suite with the peace of mind that you are fully protected and optimized.
-
Product
Saybolt Color Analyzer
-
optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.
-
Product
Measuring Stations
-
In cooperation with important customers in the automotive industry, medical engineering, mechanical engineering, and the semiconductor industry, OptoSurf has developed measuring devices that enable scattered light to be used for production purposes as well as in R&D and universities.
-
Product
Evaporative Light Scattering Detector for HPLC
ELSD-LT III
-
The evaporative light scattering detector (ELSD) is a general-purpose universal detector that can even detect components with no UV absorption, such as carbohydrates, lipids, surfactants, and synthetic polymers. With exceptional sensitivity, a wide dynamic range through Analytical Intelligence features, and easy operability using LabSolutions™ software, the ELSD-LT III contributes to more effective analysis in a wide variety of fields.
-
Product
Turbidity Measurement Products
-
Turbidity refers to the concentration of undissolved, suspended particles present in a liquid measured in Nephelometric Turbidity Units (NTU). It is important to note that turbidity is a measure of sample clarity and not colour. Water with cloudy or opaque appearance will have high turbidity, while water that is clear or translucent will have low turbidity. High turbidity value is caused by particles such as silt, clay, microorganisms, and organic matter. By definition, turbidity is not a direct measure of these particles but rather a measure of how these particles scatter light.
-
Product
Raman Probes
-
As with Raman spectrometers, a Raman probe is used to measure the inelastic scattering of light from a sample. Raman scattering is produced when the energy levels of photons are shifted up or down as a result of excitation by a monochromatic source (usually a laser). The change in vibrational frequency is used to determine the composition of a target substance.
-
Product
SERS (Surface Enhanced Raman Scattering) Substrate & SERS Reader – Mini Chemistry Analytic Pack
-
The porous carbon SERS substrate provides not only high signal enhancement due to its strong broadband charge-transfer resonance for large chemical enhancement (as opposed to electromagnetic enhancement in traditional metal-based SERS substrates), but also extraordinarily high reproducibility or substrate-to-substrate, spot-to-spot, sample-to-sample, and time-to-time consistency in SERS spectrum (which is not possible with traditional metal-based SERS) due to the absence of "electromagnetic hot spots" by making the entire surface of the substrate "chemically hot", high durability due to no oxidization, and high compatibility to biomolecules due to its fluorescence quenching capability.
-
Product
Profiling Current Meter and Wave
SeaGuardII DCP Wave
-
The SeaGuardII DCP Wave is a 600kHz Doppler Current Profiler able to measure directional wave parameters and currents from a bottom mounted installation.The Acoustic Wave software 5759 used by the DCPS implements unique features to improve the wave measurement accuracy by optimizing the signal to noise ratio.Maximum deployment depth is 40m in normal scatter conditions. The Profiling Current Meter and Waveis available as a self-recording instrument. It can be easily integrated into a real-time system offering reliable two-way communication.
-
Product
Modular SEC system
SC2000
-
The new Postnova SC2000 Modular SEC system offers unrivalled flexibility in Advanced SEC/GPC analysis. It is the first truly modular multi-detector SEC system available allowing flexible access to a wide range of applications. The system incorporates state-of-the-art detection technologies including light scattering (MALS > multi-angle light scattering) for absolute molecular weight and Viscosity detection for structural and conformational data. Many other detector and accessory options and combinations are available to build a system uniquely tailored to your application requirements, with the benefit of modularity to allow easy future expansion. In addition, the SC2000 can be further expanded to include FFF modules to widen the application range and allow both SEC and FFF separations to be carried out on the same sample within one instrument platform.
-
Product
Molecular Weight Analyzers
-
Brookhaven Instruments Corporation
Molecular weight and size are two key properties of all macromolecules including biologically important and synthetic polymers. Performance and processability are directly related to these parameters. Light scattering is capable of absolute measurements in either batch or flow mode. For distribution information, couple a GPC/SEC instrument to a light scattering detector.
-
Product
Vector Network Analyzer
-
SIGLENT Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2/4-port models that can quickly deliver reliable scattering, differential, and time-domain parameter measurements.
-
Product
C & L-Band Separate Raman Fiber Amplifier
RFA7000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
Product
C-Band Separate Raman Fiber Amplifier
RFA5000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
Product
Gloss & Reflectance
-
Visual appearance can determine a person’s perception of a product. Colour and Gloss are two key parameters that are used to define a product’s overall quality. Perception is subjective, but Elcometer’s range of gloss meters, DOI meters and colour assessment equipment can quantify appearance measurement. The ability of a surface to reflect light without scattering is known as gloss. Using a gloss meter, gloss is measured by directing a constant intensity light beam at a fixed angle to the test surface and then by monitoring the amount of reflected light at the same angle. Different surfaces require different reflective angles.
-
Product
Isolators
-
Optical isolators transmit light in only one direction. These devices are especially beneficial in preventing back-reflection and scattered light from reaching sensitive components such as lasers.
-
Product
Sample Analysis Services
-
Postnova Analytics offers a variety of unique sample analysis services for the characterization of biopolymers, proteins, liposomes and nanoparticles. Our European Application Laboratory Center EAC and our American Application Laboratory Center AAC represent the worldwide biggest and most advanced labs offering sample analysis services based on Field-Flow Fractionation and Light Scattering.