Modulation Analysis
Measure and analyze radio transmitters and communication systems.
See Also: Modulation, Optical Modulation, Modulation Analyzers, Modulation Meters, MER
-
Product
LXI Microwave Multiplexer, SP4T, 11-Bank, 50GHz, 50Ω, SMA-2.4
60-803-711
Multiplexer Module
Our 60-803-711 is a 11 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 50GHz, 50Ω, SMA-2.4
40-785C-452-TE
Multiplexer Module
The 40-785C-452-TE (PXI) and 42-785C-452-TE (PXIe) are dual SP4T 50GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe RF Multiplexer, Single 8-Channel, 3GHz, 75Ω, SMB
40-834A-001
Multiplexer Module
The 40-834A-001 (PXI) and 42-834A-001 (PXIe) are 75 Ohm 8 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI 4 Banks Of 20 Chan Screened 1 Pole MUX
40-615-021-S-4/20/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI Dual SP6T Multiplexer 18GHz 50 SMA
40-784A-022
Multiplexer Module
Pickering Interfaces’ range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50Ω and are capable of switching signals up to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors
-
Product
Signal, Module, ID, CASS, QuadraPaddle, 800 Position
510114131
ITA Module
Signal, Module, ID, CASS, QuadraPaddle, 800 Position.Mating module is 510113138.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 3-Bank 18GHz SMA
60-802-203
Multiplexer Module
The 60-802-203 is a 4-channel, 3-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI 8-slot BRIC Multiplexer, 16-Channel, 40-Pole (6 Sub-cards)
40-570A-214
Multiplexer Module
The 40-570A-214 is a 16-channel, 40-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
Signal/Micro Power/Micro Coax, Module, Receiver, TriPaddle, 90 Series, 20/20 Position
510104323
Receiver Module
Signal/Micro Power/Micro Coax, Module, Receiver, TriPaddle, 90 Series, 20/20 Position.This hybrid module provides 20 TriPaddle Signal positions and 20 Micro Power or Micro Coax positions in a single wide module slot enabling consolidation of wiring and preserving valuable space in the Receiver.*Please note: VPC receiver modules must be separated into two pieces in order to extract contacts. For detailed instructions please consult the user manual/procedure sheet for this module before extracting contacts.
-
Product
PXI Multiplexer, Dual 24-Channel, 1-Pole
40-632A-021-D/24/1
Multiplexer Module
The 40-632A-021-D/24/1 is a dual 24-channel, 1-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP12T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-222-TE
Multiplexer Module
The 40-788-222-TE (PXI) and 42-788-222-TE (PXIe) are dual failsafe SP12T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI Single SP4T Multiplexer 26.5GHz 50 SMA
40-784A-131
Multiplexer Module
Pickering Interfaces’ range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50Ω and are capable of switching signals up to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors
-
Product
PXI 6-Channel 10A Solid State SPST Switch
40-182-011
Switch Module
The 40-182-011 has 6 off high current SPST switches in two PXI slots and is part of our range of high power solid state switching solutions. Each SPST switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation.
-
Product
Signal, Module, Receiver, TriPaddle, 90 Series, 96 Position, w/ Right Angle Contacts
510104135
Receiver Module
Primary mating module 510108125. (May mate with other ITA modules, as well.)
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
Computer-On-Module
Qseven®
Computer on Module
Qseven is an off-the-shelf, multi-vendor, computer-on-module that integrates all the core components of a common x86 PC and is mounted onto an application specific carrier board. A single ruggedized 230-pin MXM connector provides the carrier board interface to carry all the I/O signals to and from the Qseven module.
-
Product
Vacuum-Pneumatic, Module, ITA, 90 Series, 1 Pos Vacuum, 2 Pos 3/8" ID Pneumatic
510108264
ITA Module
Primary mating module 510104276.
-
Product
16-Channel Multiplexer (2 / 4-Wire) Module for DAQ970A and DAQ973A
DAQM902A
Multiplexer Module
DAQM902A 16 Channel Multiplexer (2/4-wire) Module. Reed relays with high voltage switching of up to 300 V and scan speed up to 250 ch/s.
-
Product
Module, Receiver, RTCASS, Signal, 210 Position, Discrete Wiring
510113146
Receiver Module
Module, Receiver, RTCASS, Signal, 210 Position, Discrete Wiring.
-
Product
DC Power Module, 100 V, 0.5 A, 50 W
N6736B
Power Module
The N6736B is a one-slot 50 W programmable DC power module for use in the N6700 low-profile Modular Power System or N6705 DC Power Analyzer.
-
Product
PXI Prototyping Module, 1-Slot, 15-Pin D-Type
40-225A-601
Prototyping Module
The 40-225A PXI Prototyping Modules are stripped down versions of the 40-220A PXI Breadboard series. These are very basic, low cost prototype modules. They have no PXI interface but do have access to fused power supplies from the PXI backplane.
-
Product
PXI Triple SP6T Multiplexer 18GHz 50 SMA
40-784A-023
Multiplexer Module
Pickering Interfaces’ range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50Ω and are capable of switching signals up to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors
-
Product
PXI Single Microwave Transfer Switch 26.5GHz 50 SMA
40-782A-531
Switch Module
The 40-782A-531 is a single transfer switch and is part of our range of PXI microwave switching modules. It has a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 40 GHz, 50 Ω, SMA-2.9, Failsafe
42-785C-441
Multiplexer Module
The 40-785C-441 (PXI) and 42-785C-441 (PXIe) are single failsafe SP4T 40 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 50 GHz, 50 Ω, SMA-2.4, Failsafe, Remote Mount
42-782B-552-E
Switch Module
The 40-782B-552-E (PXI) and 42-782B-552-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
LXI High Voltage Switching - 8-Bank, 1-Pole, 4:1 Multiplexer Plugin Module
65-231-914
Multiplexer Module
The 65-231-914 plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber, ST Connectors
42-850A-514-M62.5
Multiplexer Module
The 40/42-850A-514-M62.5 is a PXI/PXIe 4-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
Product
LXI High Voltage Switching Multiplexer Plugin Module
65-231-707-HI
Multiplexer Module
The 65-231-707-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 7 kV. Multiplexers are created by populating the 65-200-002 scalable chassis with multiplexer plug-in modules that provide access to the Channel and Common signals on 51-pin front panel connectors.
-
Product
PXI Counter/Timer Module
Counter/Timer Module
PXI Counter/Timer Modules perform encoder position measurement, event counting, period measurement, pulse-width measurement, pulse generation, pulse-train generation, and frequency measurement. PXI Counter/Timer Modules feature up to eight 32-bit counter/timers and TTL/CMOS-compatible digital I/O. You can also choose options that support filtering, high-speed simultaneous DMA transfers, industrial voltage ranges with isolation, and onboard high-precision oscillators.
-
Product
PXI MUX 8 Banks of 8 Channel 2 Pole
40-610-022-8/8/2
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer





























