Hysteresis Loop
describes the induced magnetic flux density (B) in relation to the magnetizing force (H). Also known as: BH Loop
See Also: Hysteresis, Hysteresis Graphs, Hysteresis Curve, Core Loss, Flux Density, BH Curve
-
product
Stress Hysteresis Measurement
500 Series
Stress Hysteresis Measurement up to 500C for thermal property and stability tests of thin films in air.Non-Contact Laser Scanning Technology.
-
product
Short Circuit Loop Impedance Meter
AMZC-306
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more
-
product
Loop Tack Tester
Loop Tack Tester is applicable to measure the tack property of adhesive tapes, pressure-sensitive adhesives (PSA), and adhesive materials according to ASTM D6195.
-
product
Open Loop Current Sensor
K03
The K03 series is a current sensor based on the Hall effect. It enables the electronic measurement of direct, alternating or pulsed currents as well as their combinations with galvanic separation between primary (high current) and secondary circuits.
-
product
Loop / PFC Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
product
Multi-Standard Local Loop Simulatorw/Optional AWGN Generator
458-LM-A1-30
FEATURES: Simulates 26 AWG PIC as specified in ANSI T1.417; Bandwidth DC to 30 MHz; Solution for ADSL, ADSL2, ADSL2+, & VDSL2 chip/modem/DSLAM testing;
-
product
Array Solutions K9AY Loop Wire/Mast Kit
AS-AYL-4 WM
All materials required for the installation of your receiving loop system, have been included in this kit with the exception of those items listed below under the heading; ‘You will also need. ‘ The specified 8’ x 5/8” copper-clad steel ground rod can be purchased at just about any local hardware store or home center.
-
product
U Type Glow Wire Loop
IEC60695-2-10
Shenzhen Chuangxin Instruments Co., Ltd.
Thermo resistance, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a standardized test platelet made of plastic (or other materials) for a prescribed period of time under precise test conditions.
-
product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
product
8 Direction Receiving Loops Antenna System
AS-SAL-12/20/30 - Mark II
The Array Solutions Shared Apex Loop™ Array (AS-SAL-12 Mark II, AS-SAL-20 Mark II, and AS-SAL-30 – Mark II) is an improved version of the new type of receiving antenna that delivers exceptional directivity in a compact package and is useable over a wide range of frequencies without need for adjustment. This array opens the door to a new class of compact, high performance, wideband receiving antennasdeveloped for both amateur and professional users.
-
product
Dual Loop Master Controller
The Xcite System Master Controller provides all dual loop functions needed for accurate closed loop control and display of the static and dynamic test variables, while producing the highest electro-hydraulic frequency response. At the heart of each Xcite System is the Master Controller, a compact electronic control package which provides all of the controls and displays necessary to operate a controlled force or torque exciter system. The Xcite Master Controller is unique in that it provides electro-hydraulic excitation over a broad frequency range, unprecedented by any previous electro-hydraulic excitation system. It achieves its great frequency range through the use of sophisticated circuitry, high voltage inputs to the servovalve and compression control of the dynamic feedback variable in addition to the conventional servo control of the static loop. Static parameters such as force or displacement may be matched with dynamic control variables such as force, displacement, velocity, acceleration or strain for maximum test flexibility.
-
product
Current Loop Data Loggers
This data logger can measure and store 4~20mA DC current readings automatically. The professional applications can be provided by the PC software DGraphTM. Logger status, alarm indication and low battery indication are via flashing red/green LED and yellow LED. The button on housing can be used to start logging, or confirm and clear LED alarm when LED alarm is hold status.
-
product
Dynamic Scale Deposition Loop System
Dynamic Scale Deposition Loop fully automated systems includes hardware and software to measure and evaluate the performance of scale inhibitors under high pressure and high temperature conditions.
-
product
Quad Op-Amp Loop
QOAL400
The QOAL400 module is a precision instrument capable of measuring all common parameters of an Op Amp, including AC as well as DC parameters. The QOAL400 has four completely independent channels, which allow a quad device to be tested in a minimum amount of time. Each channel has a full set of resources to measure all common parameters.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 16 Channel
43-765-001
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
product
Line Loop Tester
8455
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
product
Current Loop Expansion Kit
OP-SB85C
This expansion kit supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Temperature Loop Control Setup
ULP-27
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
product
Loop Meters
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 12 Channel
43-765-002
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Loop Testing
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
product
Loop Calibrator
6500 LC
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
product
DC Hysteresis Graph Test System
DX-2012H
Automatic measurement of the demagnetization curve of permanent magnetic material such as ferrite, AlNiCo, NdFeB, SmCo, etc. Accurate measurement of the magnetic characteristic parameters of remanence Br, coercive force HcB, intrinsic coercive force HcJ and maximum magnetic energy product (BH)max.
-
product
Hysteresis Dynamometers
HD Series
16 Standard Models with Maximum Torque from 2.5 ozin to 500 lbin (18 mNm to 56.5 Nm)Hysteresis Braking System: Provides precise torque loading independent of shaft speedMotor Testing from No Load to Locked RotorAccuracy: 0.25% to 0.5% (Full Scale)Air Flow Sensor: For protection against overheating and operator errorStandard Torque Units: English, Metric and SIBase Plate: Available in long or short versionsCustom Dynamometers: for special torque and speed requirementsEasy Calibration
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
Opto-Isolated Current Loop Signal
4029
SPECTEC Innovative Sensor Solutions
SPECTEC's Model 4029 digital opto-isolated current loop signal conditioner prevents ground loops and interrupts any galvanic signals riding on magnetic speed sensor's output signal.. This signal conditioner converts magnetic, variable reluctance and inductive sensors' sinusoidal signals into a 4-20 mA output suitable for interfacing with process control units, dataloggers, flow controllers, and computers.
-
product
Friction Flow Loop System
Friction Flow Loop System is used for testing the effects of friction reducers by circulating at high rates through different pipe diameters. Friction Loop designs vary based on the application required.
-
product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.





























