Hysteresis Loop
describes the induced magnetic flux density (B) in relation to the magnetizing force (H). Also known as: BH Loop
See Also: Hysteresis, Hysteresis Graphs, Hysteresis Curve, Core Loss, Flux Density, BH Curve
-
product
Hysteresis Loop Tracer
MESA
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
product
Automatic Hysteresis Graph Test System
DX-4DMT
X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.
-
product
AC Hysteresis Graph Test System
DX-2012SA
Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.
-
product
Vibrating Sample Magnetometer
VSM
The VSM (also named M-H CURVE Hysteresis Graph TEST SYSTEM ) can be used for the measurement of the basic magnetic properties of the magnetic materials. Such as the Hysteresis loops of the materials, Magnetization curve, Warming Curve , Warming /Cooling curve, Cooling curve and the changes of the temperature as time goes away , then we will get some Magnetic parameters such as the Saturated strength of the magnetization, the left strength of the magnetization , Coercive force, the Max of Magnetic energy product,the Curie temperature and the Magnetic conductivity(the Initial Magnetic conductivity is included ). It can also measure the magnetic materials such as the powder, the particles, the films, the liquid and the massive.
-
product
DC Hysteresis Graph
DX-2012SD
Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability µi, maximum permeability µm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.
-
product
AC Hysteresis Graph Test System
DX-2012M
Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.
-
product
Soft Iron Tester
WP2
Computer aided measuring set for automatic measurement of the hysteresis loop of soft magnetic materials. Allows measurement of workpieces with different length and cross sections.
-
product
Material Science Laboratory Instruments
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
product
Magnet Tester
MP
Computer aided measuring desk for automatic measurement of hysteresis loop of hard magnetic materials. Use pole pieces with integrated measuring coils, or J-compensated surrounding coils.
-
product
Fluxmeter
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
product
Hysteresis Graph
MAGNET-PHYSIK Dr. Steingroever GmbH
The measurement of magnetic material parameters using hysteresis graphs is of utmost importance for both material manufacturers and users. Discover the hysteregraphs from MAGNET-PHYSIK in Cologne.
-
product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
product
Loop Meter
MZC-310S
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
product
Loop Antenna
ZHX7-0.009-200-1486
Loop Antenna, Frequency 0.009~200MHz, Linear Polarization, N-Female
-
product
Single Loop Controller
1166
The 1166 is a powerful, single loop profile controller for complex processes. It offers profiling capability with 4 programs each of 16 free format segments making it a leader in its class.
-
product
mA Loop Calibrators
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
product
Loop Calibrator
Model KM CAL-904-MK1
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
product
Loop Antennas
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
Loop Powered Indicators
DEVAR loop powered indicators are designed to easily convert any standard 4 to 20mA loop signal to readout directly in engineering units. Optional back-lit display available.
-
product
Loop A Line Products
Cable pair tracing and a lot more, Loop-a-Line products can remotely control a far end device (the oscillator) for up to 20km of cable. Using a Loop-a-Line allows the linesman to remotely change the state of the oscillator to any of five different states. Therefore eliminating the need for multiple journeys along the cable path.
-
product
MULTI-STANDARD LOCAL LOOP SIMULATOR
458-LM-A8-30
Accurately simulates attenuation and impedanceFull bidirectional operation at all specified frequencies26 AWG PIC as specified in ANSI T1.417
-
product
Open Loop Current Sensor
C03 50A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in systems for industry and commerce as well as in communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Monitoring Loops
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
product
DDS Phase Locked Loop Synthesizer
DDS Series
*Connectorized Package *Programmable Frequencies to 1 GHz
-
product
Digital Phase Locked Loop (PLL)
A6-CPS
The A6-CPS digital phase locked loop (PLL) can be customised to a specific application and shipped ready for use in production.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
Loop and Line Powered Level Switch
Safety IntelliPoint
The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
product
One Core Loop Tester
DAMUL is an innovative and portable optical power checker accompanying 1-core loop back function. DAMUL can check SFP TX and RX power level by simply inserting SFP into it. If you use UPM (Universal SFP-typed Power checker Module) optionally provided, DAMUL can measure optical power. Also, when using SPM (SFP-typed Power checker Module) optionally provided, DAMUL can identify 18 CWDM wavelengths as well as its power automatically. DAMUL provide users high productivity for optical power checking work on fiber optic systems such as WDM-PON.
-
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.




























