Hysteresis Loop
describes the induced magnetic flux density (B) in relation to the magnetizing force (H). Also known as: BH Loop
See Also: Hysteresis, Hysteresis Graphs, Hysteresis Curve, Core Loss, Flux Density, BH Curve
-
Product
Hysteresis Loop Tracer
MESA
-
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
Product
Material Science Laboratory Instruments
-
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
Product
DC Hysteresis Graph
DX-2012SD
-
Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability µi, maximum permeability µm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.
-
Product
Soft Iron Tester
WP2
-
Computer aided measuring set for automatic measurement of the hysteresis loop of soft magnetic materials. Allows measurement of workpieces with different length and cross sections.
-
Product
AC Hysteresis Graph Test System
DX-2012M
-
Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.
-
Product
Fluxmeter
-
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
Product
Vibrating Sample Magnetometer
VSM
-
The VSM (also named M-H CURVE Hysteresis Graph TEST SYSTEM ) can be used for the measurement of the basic magnetic properties of the magnetic materials. Such as the Hysteresis loops of the materials, Magnetization curve, Warming Curve , Warming /Cooling curve, Cooling curve and the changes of the temperature as time goes away , then we will get some Magnetic parameters such as the Saturated strength of the magnetization, the left strength of the magnetization , Coercive force, the Max of Magnetic energy product,the Curie temperature and the Magnetic conductivity(the Initial Magnetic conductivity is included ). It can also measure the magnetic materials such as the powder, the particles, the films, the liquid and the massive.
-
Product
Automatic Hysteresis Graph Test System
DX-4DMT
-
X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.
-
Product
Magnet Tester
MP
-
Computer aided measuring desk for automatic measurement of hysteresis loop of hard magnetic materials. Use pole pieces with integrated measuring coils, or J-compensated surrounding coils.
-
Product
AC Hysteresis Graph Test System
DX-2012SA
-
Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.
-
Product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
-
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
Product
Loop Antennas
-
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
Product
Monitoring Loops
-
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
Product
Phase Locked Loop (PLL) Synthesizer & Translation Loop
-
ADI’s industry leading phase locked loop (PLL) synthesizer family features a variety of high performance, low jitter clock generation and distribution devices. The extensive, ever growing family includes over 100 products, optimized for high data rate, low jitter clocking applications. The portfolio features PLLs, PLL/VCOs, and distribution chips, designed for clocking applications where synchronization, clock distribution, and phase noise performance are all vitally important.
-
Product
Loop Antennas
-
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
Product
Hysteresis Graph
-
MAGNET-PHYSIK Dr. Steingroever GmbH
The measurement of magnetic material parameters using hysteresis graphs is of utmost importance for both material manufacturers and users. Discover the hysteregraphs from MAGNET-PHYSIK in Cologne.
-
Product
One Core Loop Tester
-
DAMUL is an innovative and portable optical power checker accompanying 1-core loop back function. DAMUL can check SFP TX and RX power level by simply inserting SFP into it. If you use UPM (Universal SFP-typed Power checker Module) optionally provided, DAMUL can measure optical power. Also, when using SPM (SFP-typed Power checker Module) optionally provided, DAMUL can identify 18 CWDM wavelengths as well as its power automatically. DAMUL provide users high productivity for optical power checking work on fiber optic systems such as WDM-PON.
-
Product
Loop Meters
-
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
Product
Hysteresis Dynamometers
HD Series
-
16 Standard Models with Maximum Torque from 2.5 ozin to 500 lbin (18 mNm to 56.5 Nm)Hysteresis Braking System: Provides precise torque loading independent of shaft speedMotor Testing from No Load to Locked RotorAccuracy: 0.25% to 0.5% (Full Scale)Air Flow Sensor: For protection against overheating and operator errorStandard Torque Units: English, Metric and SIBase Plate: Available in long or short versionsCustom Dynamometers: for special torque and speed requirementsEasy Calibration
-
Product
Active Dual Loop Antenna
KH30936
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
Product
Short Circuit Loop Impedance Meter
AMZC-305
-
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
Product
Antenna, Active Loop
EM-6876 | 9 KHz – 30 MHz
-
The Electro-Metrics EM-6876 Active Loop Antenna is used with EMI Receivers and Spectrum Analyzers with 50 ohm input and covers the frequency range of 9 kHz to 30 MHz.
-
Product
Recorder for non-stop(Loop)
-
You just set the desired number of the days to keep track of, and Stream MultiRec will record them uninterruptedly 24 hours a day with no human intervention. The number of tracked channels is defined by the user depending on specific requirements and the storage capacity of the video server in use.
-
Product
Single Loop Controller
1462
-
The N4400 is a sophisticated, single loop controller which provides extensive profiling programming options for complex processes. The controller can create a profile with up to 121 segments, store up to 8 programs and configure and store extra programs on a PC.
-
Product
Three Loop Antenna
VVLA-30M
-
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
Product
Local Loop Simulator 128 Channels
458-CC-16/458-CM
-
FEATURES: Accepts 1 to 16 Line Modules; User-Friendly Interface; Multiple Configurations; Field-Upgradeable Software; One-Year Warranty/Calibration. The 458 Series 16-slot Chassis, which consists of the 458-CC chassis and one of three control modules, provides a wide variety of configurations through use of up to 16 plug-in Line Modules.
-
Product
Current Loop Adapter
OP-1C
-
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
Single Loop Controller
1460
-
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
Product
Short Circuit Loop Impedance Meter
AMZC-306
-