Banks
-
Product
PXIe-2524 , 128‐Channel, 2 A, Multibank, 1‐Wire PXI Multiplexer Switch Module
780587-24
Multiplexer Module
128‐Channel, 2 A, Multibank, 1‐Wire PXI Multiplexer Switch Module —The PXIe‑2524 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 1‑wire multiplexer configurations: 16 bank 8x1, octal 16x1, quad 32x1, dual 64x1, and 128x1. The PXIe‑2524 also features onboard relay counting for relay monitoring.
-
Product
PXI/PXIe High Voltage Multiplexer, Dual 11-Channel, 1-Pole
42-321-105-HI
Multiplexer Module
The 40-321-105-HI (PXI) and 42-321-105-HI (PXIe) are dual 11-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-010-006
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-315-005
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI/PXIe RF Matrix, Single 2x2, 2.5GHz, 50Ω, SMB
40-877A-001
Matrix Switch Module
The 40-877A-001 (PXI) and 42-877A-001 (PXIe) are 50Ω 2x2 RF matrices with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
Quad QSFP28/QSFP+ FMC+ Module
FPGA Board
iWave’s QSFP28/QSFP+ 2×1 Stacked FMC+ HSPC Module is designed to meet VITA 57.4 FMC+ Standard. This FMC+ Module is supported by two stacked QSFP28/QSFP+ ports(Upto400G) with 4-Bit Silicon Labs programmable clock synthesizer (default = 156.25Mhz). A flexible reference clock for on the QSFP28/QSFP+ 2×1 Stacked FMC+ Module is fully programmable over the 0.16 to 710 MHz range through I2C. Each QSFP28/QSFP+ ports are directly connected to four multi-gigabit serial transceivers banks of Vita 57.4 compliant carrier Board.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-007
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 1-Bank 40GHz SMA-2.9
60-801-401
Multiplexer Module
The 60-801-401 is a 6-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
4 2/3 Digits Voltage/Current Meter
CS2-VA
-
CS2-VA Voltage/Current Meter is designed with high accuracy measurement, display and communication of 0~600V or 0~10A for DC/AC/TMRS.● ADTEK builds flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also build in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-210-014
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI Dual 18 Channel MUX, 96-Pin SCSI Connector
40-735-912-S1
Multiplexer Module
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 10-Bank 26.5GHz SMA
60-802-310
Multiplexer Module
The 60-802-310 is a 4-channel, 10-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI Microwave Multiplexer, SP4T, 3-Bank, 26.5GHz, 50Ω, SMA
Multiplexer Module
Our 60-803-303 is a 3 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, Terminated, 3GHz, 50Ω, MCX
42-873A-101
Multiplexer Module
The 40-873A-101 (PXI) and 42-873A-101 (PXIe) are 4 to 1 RF MUX with 1 bank in a single slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 50Ω, SMB
42-872A-001
Multiplexer Module
The 40-872A-001 (PXI) and 42-872A-001 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
Analog Sequencers
-
Analog sequencers from Analog Devices integrate accurate comparators with the control functionality of power-on and power-down sequencing for voltage regulator banks. The comparators monitor the regulator voltage outputs and trigger the turn on of next rail in the system after a preconfigured time delay. Some members of this portfolio can be cascaded together, which provides scalable solutions to expand functionality across multiple devices. Our analog sequencers provide an easy to use solution for power sequencing challenges in cellular infrastructure, telecommunication, data communication, and data center applications.
-
Product
LB-Series Digital AC Load Banks
-
The LB-Series AC Load Banks are designed for high power portable load testing of generators, UPS, and other critical AC power sources. Available models meet a range of voltages including but not limited to 208, 380, 440, and 480 VAC. Load power model options reach 1000 kW standard with other options available.
-
Product
PXI/PXIe RF Matrix, Single 2x2, 2.5GHz, 50Ω, SMB
42-877A-001
Matrix Switch Module
The 40-877A-001 (PXI) and 42-877A-001 (PXIe) are 50Ω 2x2 RF matrices with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
LXI Microwave Multiplexer, SP4T, 8-Bank, 26.5GHz, 50Ω, SMA
60-803-308
Multiplexer Module
Our 60-803-308 is a 8 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Software Testing & Quality Assurance Services
-
We have deep expertise in various spheres: finance, banking, e-commerce, education, healthcare, entertainment, telecom, travel, aviation, natural resources and others. Our strong quality assurance team can start testing your project of any complexity within 24 hours. Convenience for TestMatick`s customers consists in the proper mix of technical skills of the team, understanding of the business process, special industry knowledge, professionally built testing processes and methodology. Mobile Application and Smartphone Testing: We ensure quality of the entrusted to us mobile software products carefully testing them on the required mobile platforms. Automated Software Testing For Quality Assurance. T
-
Product
LXI Microwave Multiplexer, SP4T, 11-Bank, 18GHz, 50Ω, SMA
60-803-111
Multiplexer Module
Our 60-803-111 is a 11 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, 3GHz, 50Ω, SMB
42-872A-004
Multiplexer Module
The 40-872A-004 (PXI) and 42-872A-004 (PXIe) are 50 Ohm 4 to 1 RF multiplexers available with 4 banks in a single PXI slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-410-008
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI 24xSPST High Voltage Power Relay Module
40-330-001
Relay
The Pickering Interfaces 40-330 High Voltage Power Relay Module is suitable for applications requiring high voltage power relay switching with high density.It features current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching. It is configured as a bank of 12, 18 or 24 separate Single Pole Single Throw (SPST) relays. Connections are made via a front panel mounted 50-pin (24xSPST) or 37-pin (18 and 12xSPST) high voltage D-Type connector.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, 3GHz, 50Ω, SMB
40-872A-004
Multiplexer Module
The 40-872A-004 (PXI) and 42-872A-004 (PXIe) are 50 Ohm 4 to 1 RF multiplexers available with 4 banks in a single PXI slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-215-007
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI/PXIe RF Switch, Hex SPDT, 3GHz, 75Ω, MCX
40-830A-106
Relay
The 40-830A-106 (PXI) and 42-830A-106 (PXIe) are 75Ω RF switches with 6 separate SPDT relays slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
LXI Microwave Multiplexer, SP6T, 1-Bank, 67GHz, 50Ω, SMA-1.85
60-800-801
Multiplexer Module
Our 60-800-801 is a 1 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 11-Bank 40GHz SMA-2.9
60-801-411
Multiplexer Module
The 60-801-411 is a 6-channel, 11-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.





























