Banks
-
product
Load Banks
BD Series
*12 kW, 15kW and 18kW Battery Discharge Load DC*All of our Load Banks are continuously rated for Power and Current.
-
product
DC Load Banks
Custom DC Units
Mosebach Manufacturing Company
Mosebach has been building DC load banks for over 30 years. We have a wide range of custom-designed units. Please give us a call at 1-866-629-4328 to discuss your needs.
-
product
Anti-Islanding Load Banks
AI-Series
AI-series anti-islanding load banks containing purely resistive, inductive, or capacitive load, have segmented combination control of power input, and can simulate a variety kinds of power loads to meet the grid-connected inverter full load test requirements.
-
product
Rack Mounted Load Banks
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
product
Filters & Switch Filter Banks
PMI offers the highest quality filters, switch filter banks, filter assemblies, diplexers, multiplexers for industrial and military applications in the frequency range of DC to 40 GHz. All PMI’s Switch Filter Banks use PMI’s proprietary Solid-state Switch designs, which offer high speed and improved performance. While there are many standard models, PMI can design and build to meet your specifications.
-
product
AC Load Banks
X60C Series
Mosebach Manufacturing Company
The X60C is a small suitcase style 60 kW load bank.
-
product
Switched Filter Banks
K&L Microwave provides Switched Filter Bank (SFB) products built to customers' electrical, mechanical, and environmental specifications. The list below contains part numbers meeting existing industry and customer specifications. Use the quote cart to request a quote on an existing design or to provide specifications for a custom design.
-
product
Specialty/Custom Load Banks
XLHV Medium Voltage Series
Mosebach Manufacturing Company
The XLHV range offers you a continuous load at higher voltages in an outdoor rated enclosure. These can be for AC or DC load banks up to 15kV.
-
product
PXI/PXIe LVDT/RVDT Simulator Module, 4-Banks
41-670-101-AABBCC
The 41/43-670-101 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
PXI MUX 4 Banks of 16 Channel 2 Pole
40-610-022-4/16/2
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI/PXIe Resolver Simulator Module, 4-Banks
41-670-201-AABBCC
The 41/43-670-201 is ideal for the simulation of Resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire resolver.
-
product
AC Load Banks
Power House Manufacturing, Inc.
Hand carried AC load banks in any capacity to meet your load testing needs. Power House Manufacturing has developed the best ultra-compact and light-weight hand carried AC load banks. AC load banks with capacities unmatched in the industry.
-
product
AC Load Banks
XL2000-XL3000 Series
Mosebach Manufacturing Company
The XL2000-XL3000 Series is a group of outdoor rated load banks ranging from 2000 kW to 3000 kW. These load banks range in features from permanently mounted with direct bus bar connections to trailer mounted and easy disconnect cam lock connections. Mosebach can also integrate a wide variety of control systems into the load bank to meet your needs.
-
product
PXI 8 Banks of 8 Chan 1 Pole MUX
40-657-001-8/8/1
40-657 High Density Power Multiplexer Modules are available in a choice of configurations, containing up to 8 separate multiplexers, all 1-pole switching. They are suitable for switching signals to 110VDC/250VAC at 2Amps, 90W.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 2-Banks
41-670-003-AABBCC
The 41/43-670-003 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
product
AC Load Banks
XL1500 Series
Mosebach Manufacturing Company
The XL1500 Series of resistive load banks are designed for testing power supplies up to 1500kW of various voltages.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 4-Banks
41-670-001-AABBCC
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
Combined Load Banks
C-Series
C-series combined load banks are devices which contain resistive and reactive loads, apply the load to an electrical power source and dissipate the power of the electrical power.
-
product
DC Resistive Load Banks
LB-Series
Eagle Eye offers multiple DC Load Banks ranging from 10 480 VDC at 1 amp or 5 amp Resolution. These load banks offer a simplistic solution to UPS Battery Load Testing. Each load bank is easy-to-use with an LCD display operator control panel and user-friendly fan switches, load step switches, and master load switches. UPS load testing stimulates a real-world performance demand of a critical power
-
product
AC Load Banks
XL1000-XL1250 Series
Mosebach Manufacturing Company
The XL1000-XL1250 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
product
PXI MUX 8 Banks of 8 Channel 2 Pole
40-610-022-8/8/2
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
DC Load Banks
Guangdong EMAX Electrical Co., Ltd.
DC load banks for all voltage levels and power test applications, available in a variety of models including portable and fixed models.
-
product
PXI/PXIe Resolver Simulator Module, 4-Banks
43-670-201-AABBCC
The 41/43-670-201 is ideal for the simulation of Resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire resolver.
-
product
PXI MUX 8 Banks of 16 Channel 1 Pole
40-610-022-8/16/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 4-Banks
43-670-001-AABBCC
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal.
-
product
PXI 10 Banks 0f 8 Channel 1 Pole MUX
40-615-021-10/8/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
Load Banks
EL Series
*12kW, 15kW and 18kW DC Electronic Load*All of our Load Banks are continuously rated for Power and Current.
-
product
Radiator Mount Load Banks
Mosebach Manufacturing Company
Help prevent wet stacking in diesel gensets with a radiator or duct mounted load bank. Being a supplemental load, Mosebach has a solution to fit your needs.