-
Product
Chemiluminescence NO/NO2/NOX Analyzer
Model T200
-
Teledyne Advanced Pollution Instrumentation
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.
-
Product
Dynanometer Roller Set
FPS 2700 | VP 230048
-
Maschinenbau Haldenwang GmbH & Co. KG.
The FPS 2700 roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97. As a result of the increased tractive force of its eddy current brake, the FPS 2700 is additionally suitable for power measurements at constant speed and constant tractive force.
-
Product
On-Board Systems
OBS-ONE series
-
HORIBA developed the OBS-ONE series on-board emission measurement system in response to new requirements for exhaust emissions measurement from vehicles being driven on public roads (Portable Emissions Measurement Systems - PEMS). This development has been made possible by reducing the dimensions and power consumption of laboratory grade analyzers and ensuring that the system components have excellent vibration resistance. The OBS-ONE series continuously measures not only the concentration of CO, CO2, THC and NOx, but also measures exhaust fl ow rate and A/F ratio to calculate mass emission and fuel economy.
-
Product
Engine & A/C
-
A specialized range of diagnostic tools, specifically exhaust gas analyzers and vehicle air conditioning test equipment.
-
Product
Volkswagen Oxygen Sensor
KS60113 - Volkswagen
-
Konstar Electric Industrial Co., Ltd
An oxygen sensor, also known as a lambda sensor, continually detects the oxygen content in the exhaust gases of an engine. The oxygen sensor output signal informs the vehicle's ECU (Electronic Control Unit) whether the AFR (Air-Fuel Ratio) is lean or rich. Based on this, the ECU adjusts the amount of fuel injected into the engine to achieve an optimal AFR.
-
Product
Vehicle Actuator Tester
7651
-
Peaceful Thriving Enterprise Co Ltd
This device is design to test electronic components actuate by magnetic field or electronic magnetic field. Devices like actuator, ignition coil, AC generator, indoor air blower, valve controller EGR (exhaust gas control), injector, spark plug, relay and hall effect sensor can be tested.
-
Product
Electro-optic Test Bench for IR Detectors
BIRD 210
-
Testing detectors requires the implementation of ultra-low noise driving electronics and presenting high quality optical stimuli to the detector under test. This meets all these requirements and allows to test any type of detector by easily implementing the detector’s driving signals and providing exhaustive and accurate measurement results.
-
Product
Mobile Testing
-
Mobile devices are inarguably the most disruptive technology invention in recent times and have had an impact on human lives like no other. With a number of mobile devices surpassing the number of human population on earth, making your application mobile-ready is key to keeping today’s digital consumers happy. Across enterprises of all sizes, mobile apps have fuelled growth in the business operations and customer services. However, with the variety of platforms, devices and networks, there is significant infrastructure required for mobile application testing. The testing either is not exhaustive or very costly due to the sub-optimal approach used for testing.
-
Product
Exhaust Gas Analysers
-
Designed specifically for the busy workshop environment, it incorporates the fastest MoT test procedures, developed in-house here at Boston and using our newly released SW900 product control software.
-
Product
Stack Gas Analysis System
ENDA-5000 series
-
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
Product
Acceleration Simulation Mode (ASM) for Single Driven Axle Vehicles
ASM_AF | VP 230045
-
Maschinenbau Haldenwang GmbH & Co. KG.
The ASM-AF roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97. The ASM-AF is built into the base.
-
Product
Indirect Sequential Injection
-
The ECU is designed to exploit the chemical-physical characteristics of the gas fuel used in Otto engines while maintaining the level of emissions of the exhaust gas according to the original standard car.The connector used in Air 48 is automotive type 48- Poles . The connection to the engine signals , offers exceptional qualities of connective security and protection against water infiltration .
-
Product
Oxygen Sensor
KS60003
-
Konstar Electric Industrial Co., Ltd
An oxygen sensor, also known as a lambda sensor, continually detects the oxygen content in the exhaust gases of an engine. The oxygen sensor output signal informs the vehicle's ECU (Electronic Control Unit) whether the AFR (Air-Fuel Ratio) is lean or rich. Based on this, the ECU adjusts the amount of fuel injected into the engine to achieve an optimal AFR.
-
Product
Standard Industrial Ovens
-
ESPEC offers two types of standard models: the space-saving PV vertical ovens and the PH horizontal ovens. Both provide horizontal airflow for even exposure to all samples. Control constancy as low as ±0.1°C and uniformity as low as ±0.5°C ensures accurate operation. An exhaust damper is included to ventilate the oven and allow quick cool-down.
-
Product
Walk in Explosion-proof Chamber (Auxiliary Equipment)
-
Guangdong Bell Experiment Equipment Co.,Ltd
DGBELL Walk in Explosion-proof Chamber is mainly used to test the safety performance of lithium ion battery, battery pack. Prevent test operators and other test equipment from being burned and exploding. At the same time, the explosion-proof test chamber with the smoke exhaust system can discharge the smoke generated in the test to the outside.
-
Product
Fume Hood Controller
FHC50-01
-
Fume hoods are a primary source of protection in laboratories. Face velocity measurements are often used to gauge the performance of a fume hood’s ability to contain and exhaust harmful vapors. By measuring and controlling face velocity, TSI FHC50 Fume Hood Controllers provide a higher level of fume hood safety and energy efficiency.
-
Product
DEF Refractometer - Urea Scale
DEF-201
-
The MISCO DEF-201 digital refractometer is the ideal method for testing and monitoring the concentration of urea-based Diesel Exhaust Fluid (DEF or AdBlue) required by diesel engines equipped with Selective Catalytic Reduction (SCR) technology. This refractometer has a single scale for DEF concentration.
-
Product
On-board Emissions Measurement System for NH3/N2O
OBS-ONE IRLAM Unit
-
The OBS-ONE IRLAM unit is an on-board emissions measurement system for analyzing the NH3/N2O under real-world driving conditions and supports our customer’s future regulatory development.The IRLAM unit combines with the GAS unit and the PN unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).
-
Product
Combination Exhaust Tester for Petrol- and Diesel- Powered Vehicles with Innovative Condensate Separation
MET 6.3 | VP 135213
-
Maschinenbau Haldenwang GmbH & Co. KG.
The combination tester is designed for the measurement of petrol- and diesel-powered vehicles. The MET 6.3 stands out for its innovative condensate separation thanks to an active water separator. In addition, low weight, compact design and short warm-up time ensure easy handling. Part of the equipment is a 2 m (optional 4 m) long probe for both engine types.
-
Product
Exhaust Gas Thermocouples
HYBRID Series
-
The AMETEK Hybrid Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading an older style Exhaust Gas Thermocouple.
-
Product
Environmental Control Systems
-
We are committed to developing eco-friendly technologies that reduce energy use and emissions without affecting flavor or aroma. Our equipment features thermal and catalytic exhaust air-cleaning systems and process-integrated energy recovery systems to ensure efficient, compliant operations.
-
Product
Alfa Romeo Oxygen Sensor
KS60113 - Alfa Romeo
-
Konstar Electric Industrial Co., Ltd
An oxygen sensor, also known as a lambda sensor, continually detects the oxygen content in the exhaust gases of an engine. The oxygen sensor output signal informs the vehicle's ECU (Electronic Control Unit) whether the AFR (Air-Fuel Ratio) is lean or rich. Based on this, the ECU adjusts the amount of fuel injected into the engine to achieve an optimal AFR.
-
Product
Exhaust Fan
CF-400-X
-
This UL approved exhaust fan is typically installed in cabinet top panels, but has many applications. This fan requires a 10” diameter area and extends approximately 4” inside the panel.
-
Product
Multispectral Fixed Camera for Early Fire Detection
FH-Series R
-
The FLIR FH-Series R are ruggedized, multispectral fixed cameras that integrate industry-leading thermal imaging with 4K visible imaging to provide rapid visual verification of hot spots in early fire detection applications. When a hot spot or temperature change is detected, the contactless temperature measurement is sent to the operator through a connected Video Management System (VMS) for instantaneous assessment and deployment of response tactics. Custom scheduling provides security personnel the flexibility to enable and disable alarms depending on business hours and seasonality. Combining the power of thermal hot-spot detection with intelligent vehicle detection, false alarms from hot exhaust pipes can be dramatically reduced.
-
Product
Bench Top Ionizer Cleaning Box
EC-B
-
Panasonic Industrial Devices Sales Company of America
The EC-B Bench Top Ionizer allows direct ion emission to be paired with pulsed air emission to provide quick and effective removal of static charges as well as any dust that is present on the part. Three white LEDs illuminate the work piece to ensure complete dust removal. A powerful dust collecting fan exhausts dust quickly, preventing re-adhesion of dust.
-
Product
Smart Optimization
-
A reflow oven or wave solder machine is capable of literally billions of alternative setups. Each combination of zone temperatures and conveyor speed will produce a unique profile for a processed product. KIC's software makes an exhaustive analysis of all the setups and it recommends the very best oven/machine recipe within seconds.
-
Product
Housed Temperature Sensors
-
Exhaust Gas Temperature Sensors from Variohm are rich in pedigree for Motorsports success and with a strong reputation for high reliability and durability across a broad spectrum of applications for exhaust gas monitoring. The Exhaust Gas Temperature Sensors are based around a type K thermocouple in a robust design which has been well proven in Motorsport and similar demanding environments.
-
Product
Fume Hood Monitor
FHM10
-
Fume hoods are a primary source or protection in laboratories. Face velocity measurements are often used to gauge the performance of a fume hood’s ability to contain and exhaust hazardous chemicals. By accurately measuring face velocity and alarming on unsafe conditions, TSI’s FHM10 Fume Hood Monitors provide a high level of fume hood safety. And, the FHM10 helps users comply with standards and regulations set forth by OSHA, NFPA, ANSI Z9.5, and SEFA, calling for monitors to be installed on fume hoods.
-
Product
LAMBDA METER
LA4
-
This stand-alone device has a wide measuring range for determining lambda, A/F ratio, and oxygen content. The sensor's short heating time results in fast measuring response. The measuring system reacts quickly to exhaust gas modifications. The device offers analog output of the physical value (parameter setting), as well as a download of characteristic curves for specific fuels.
-
Product
Handheld Emission Particle Counter
HEPAC
-
Naneos Particle Solutions gmbh
Exhaust gas contains a lot of humidity, which can condense in the measuring device when the gas cools down. This could lead to problems with the measurement. Therefore, corresponding sensors are heated or the gas gets previously diluted. Exhaust gases from petrol and natural gas vehicles, however, contain a lot more humidity, which is why the device should only be used for diesel exhaust gases.





























