Standard Transformers
-
product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40B
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Transformer Testing Panel
TRMS Voltage 600V /1200V Phase,1050V / 2100V Line TRMS Current 80A / 160A Direct USB , RS-232 / RS-485 interface & Free Software 20 X 4 LCD Display & Ultra Glow Red LED Display High Speed Measurement in 0.25Sec (Optional) Tamper Proof Calibration & Long term stability User Friendly Operation NABL certified in EQDC & ERDA
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T1-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Automatic Transformer Observation System
ATOS
Raytech – The World leader in design and manufacturing of high-quality precision measuring instruments and systems, offering flexibility and versatility. Our modular Automatic Transformer Observation System (ATOS) allow you to create a unique and custom solution for any application. ATOS is designed to drastically reduce measuring time and increase test performance, without losing accuracy compared to individual test instruments. With the choice of up to three Multiplexers (primary, secondary, and tertiary), three Winding Resistance Meters, each with three maximum current range options (up to 15A, 50A, or 100A), Turns Ratio, and Integrated power security and safety panel (ISU R), Raytech can create a system with your needs and budget in mind.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-V
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
product
Solution Standard Reference Materials
NCS Testing Technology Co., Ltd.
Solution Standard Reference Materials by NCS
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I35-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard Gain Horn Antenna
ZLB7-600-700-1846
Standard Gain Horn Antenna, Frequency0.6~1GHz, Gain10dBi, Power 200W, WR1150, Flange FDP8, Linear polarization, N type Female connector
-
product
OIP TYPE VOLTAGE TRANSFORMER
12kV - 145kV post type voltage transformers having Oil Impregnated Paper( OIP) as major insulation has been designed with several unique features.OIP insulated outdoor products are subjected to extreme climatic conditions and hence extra care is taken in the design and manufacturing of such transformers.
-
product
Standard Test Systems
WaveCore™ Products
Textron Systems’ WaveCore family offers a variety of standard test systems with a primary application of satellite payload lab testing. Our systems can be deployed affordably for both production and engineering applications, providing industry-leading levels of data correlation with high system mean time between failures and low mean time to repair.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4J
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Portable Three-Phase Energy Standard
PEWM-3C
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
product
Transformer Turns Ratio Meter
TTRM 301
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L18-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard Accessory Replacement Kit for PP017/PP018
PKIT4-5MM-101
Standard Accessory Replacement Kit for PP017/PP018.
-
product
Loading Transformer
CL-6
This readily portable Knopp Loading Transformer weighs only 60 pounds and measures 12″ long, 9″ wide, and 10″ high. Its sturdy enclosure provides protection and adequate ventilation. Two convenient carrying handles are provided. The insulating terminal panel is rigidly secured to the transformer frame, and heavy-current, bus-bar-type terminals are securely bolted to the panel. The two outpout terminals each have two connection surfaces, one on a vertical plane and one on a horizontal plane, for maximum convenience in connecting the heavy current leads and in changing, when necessary, the series-parallel links. The links and the output connections cannot interfere with each other. All terminals and connection links are plated
-
product
Transformer Rated Metering Site Training Bench
Model 8833
The PowerMaster® 8813 is a true 3-phase training simulator for metering technicians to help improve their troubleshooting skills for applications encountered in the field. The Model 8813 provides a safe, controlled environment to help the trainee accelerate their education in meter testing and wiring verification. The training simulator also features the ability to simulate over 28 commonly found metering errors in the field. Paired with the Training Administrator Station (TAS), the bench can be controlled remotely over a closed WIFI network, and each trainee’s performance is recorded and time stamped for every session.
-
product
Standard Resistor Oil Bath
9400
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
product
ANSI Relaying Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Transforming Analog Circuit Breaker Testers
MAC-21
The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Transform Imagery into Geospatial Understanding
Feature Analyst™
Textron Systems' Feature Analyst is tightly integrated with the Esri® ArcGIS® platform to extract feature data from imagery in order to populate geographic information systems (GIS) databases. Analysts can rapidly and accurately collect vector feature data from high-resolution satellite and aerial imagery in order to gain spatial understanding.
-
product
Industry Standard in Noise Measurement
PN9000
The PN9000 is a simple and fast Automatic Phase Noise Test System covering a very wide frequency range(2 MHz to 140 GHz). Its modular architecture allows optimum configuration, multiple measurement techniques and future growth in a compact instrument.
-
product
Current Transformer
OutputDC 10VLinearityAs graph aboveApplied VoltageAC 2000V, 1min (between aperture and terminals)ImpendanceDC 500V, over 100M (between aperture and terminals)Fire Retardant Level94V0Output Terminals2.54 mm pinAnti-vibration50 Hz 5G
-
product
Inductance Standard
1482 Series
The GenRad 1482 Standard Inductors are the standard of choice in metrology labs. Used today by national metrology institutes and primary standards bodies around the world, these inductors have no peer or equivlent.