Standard Transformers
-
product
Transformer Loss Measurement Systems
Measurements International Ltd.
The Transformer Loss Measuring System stands as a pivotal tool in ensuring the quality assessment of transformers. It plays a vital role in accurately measuring and evaluating the transformer’s performance by assessing both its no-load loss and load loss. Understanding these losses is essential in determining the efficiency and overall quality of the transformer, offering valuable insights for maintenance and improvement strategies.
-
product
Standard 1.63 (46.00) - 4.50 (128.00) Battery Probe
CP-059-19
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
product
Capacitance Standard
GenRad 1417
The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.
-
product
Four Terminal Pair Standard Resistor Set
42030A
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
product
Transformer Insulation Testing
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
product
Transformer Oil Dielectric Strength Testing
LS -JJ-II
Chongqing Lushun Scientific & Technological Development Co., Ltd.
1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.
-
product
Standard Directional Gyroscopes
4000B-series
The 4000B is our standard air-driven directional gyro. As the aircraft turns left or right, gears on the sensing unit and dial shaft translate this rotation into rotation of the instrument’s vertical dial. Left turns produce clockwise dial rotation and right turns produce counter-clockwise rotation. The gyro is controlled by a heading selector knob located on the lower left of the instrument. Pressing and turning the knob first disengages the dial shaft and then resets the dial to a new heading, which results in a new course indication. Releasing the selector knob re-engages the dial shaft. The on-course position of the pointer is always at the top of the azimuth circle (0° on the dial with the aircraft headed north).
-
product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
product
Standard Probe Station Chucks & Accessories
In this test solutions section of our website we describe the expanding line of Abet PV IV probe stations for the growing variety of solar cell types and sizes being developed around the world. This page describes a line of vacuum chucks and accessories for top/bottom, top/top, and bottom/bottom solar cells from 3 x 3 mm to 300 x 300 mm. Probe stations for multiple device on a single substrate and multifunction probe stations are described further in the sections highlighted to the left of this page.
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z1-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
600MM 24In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles, IP54 Standards
DL406
Advance Plus Trading Co., Ltd.
Model Number: DL406 Key Specifications/Special Features: 600MM 24INCH Digital Level with level bubbles,LCD bright backlight display, IP54 standards 1. 600mm 24 inch level with 2 bubbles, 600*28*64mm(L*W*H), net weight: 520g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13.Handshank design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1T
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4L
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
product
CPCI-S.0 Standard Compliant Peripheral Board Controlled by a PCIe Channel Derived from the Backplane Connector P1
MIC-3820
MIC-3820 is a 2.5" on board SSD/HDD carrier board running at SATA Gen3 speed. A fast swap of the drive can be accomplished via a reserved thumb screw to help open a door on the front panel and eject the drive. The excellent mechanical design makes it easy to replace modules.
-
product
Multi Mount Transformer
UET101
UEi Test & Measurement Instruments
Multi Mount Control and Ringer transformer.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1G
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-W
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
product
Standard Climatic Test Chamber(Environmental Chamber)
Guangdong Test EQ Equipment co., Ltd.
Primarily used for accelerated damp heat testing, alternating damp heat testing, constant humidity testing, as well as high/low temperature routine testing, cold resistance testing, low-temperature storage, and adaptability testing under rapid or gradual temperature changes in industries such as aviation, aerospace, electronics, instrumentation, electrical products, materials, components, equipment, and complete machines. It is particularly suitable for Environmental Stress Screening (ESS) testing of electrical and electronic products or for enhancing production efficiency. It enables analysis and evaluation of performance and behavior under simulated environmental conditions.
-
product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25F-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1UN-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02